How do you secure an old work electrical box?

Quote from the video:
Quote from Youtube video: The box and feather the opening with the edge of the utility knife until the box fits snug to install run wires into the box and position it in the hole.

How do you secure a wire to an electrical box?





Use a cable ripper to strip about 12 inches of sheathing from the end of the cable. Cut off the excess sheathing with a utility knife. Feed the cable through the cable clamp until there is a 1/2-inch of sheathed cable inside the breaker box. Tighten the cable clamp to secure the cable.

Can you screw in an old work box?

The purpose/advantage of an old work box is that you use it where there is no stud to attach to. The tabs bind it to the drywall. If you use the tabs then you do not need to screw it to a stud. IF you have a stud to attach to then you would use the box that jack recommends in his answer.

How do you install an old work metal electrical box?

Quote from the video:
Quote from Youtube video: And look for the title rewire. An old house series in most cases it's easy to install an old work box the box is inserted into the opening in the drywall.

How can I secure my electrical box without studs?

Here’s how to install an electrical box without a stud using a winged remodel box:

  1. Trace the outline of the box onto the wall.
  2. Use a keyhole or drywall saw to cut out the shape.
  3. Thread the cables into the box and secure them.
  4. Push the box into the hole and ensure it is snug.
  5. Secure the box properly by using screws.

How much weight will an old work box support?





Suitable for fixture support up to 50 lbs. With the the old work version(B618R), it states.

What is used to secure nonmetallic cables to an electrical box?

Nonmetallic-sheathed cable shall be supported and secured by staples, cable ties, straps, hangers, or similar fittings designed and installed so as not to damage the cable, at intervals not exceeding 1.4 m (4 ½ ft) and within 300 mm (12 in.) of every outlet box, junction box, cabinet, or fitting.

What happens if you don’t ground a metal box?

A grounded metal box is important to have as it sends the electricity through the ground to the breaker box that is also grounded. Surges in the electricity a box that is not grounded allows the electricity to go where it wants to. This is not a good thing and can cause electrocution or fire.

Do junction boxes need to be secured?

Securing Cables



Article 334.30 states that cables coming out of the junction boxes should be secured within 12 inches of the box in all boxes equipped with cable clamps. These cable clamps are not to be removed. 314.17(C) states that cables must be secured to the receptacle box.

How do you mount a metal electrical box?



Quote from the video:
Quote from Youtube video: I put the screws in those two holes. And there you have it it is that easy we chose the stud. We chose the side of the stud.

Do metal electrical boxes need to be grounded?

yes, the box should be grounded. It should not be grounded through the devices, but by means of a machine screw, clip, or through metal conduit.

How do you install a metal receptacle box?

Quote from the video:
Quote from Youtube video: And this gets a little tricky because the hook needs to go in the same. Direction that the screw goes in so it snugs up in tightens. So let's go ahead and get it into the right orientation.

What screws to mount electrical boxes?



The most common electrical box screw sizes are 6-32 and 8-32. Be sure to get round head or hex-head screws for inside the box, to prevent arcing. Use oval-head screws to attach cover plates.

How do you use a metal electrical box?

Use a metal electrical box when metal-sheathed cable (also called armored BX cable) or metal conduit is running in or out of the box. Metal cable and conduit depend on the contact from its metal sheathing to the metal box to complete grounding. Also, use metal boxes with interior exposed applications.

Can I attach ground wire to mounting screw?

You attach the ground wire from the supply cable to the metal box. Always. If the lamp has a metal frame, and the box is metal, it can ground itself through the mounting screws. Otherwise you’ll need a 3-way pigtail between a pigtail off the box, the supply wire, and the lamp’s ground.

How do you install a ground screw in a metal box?

If a metal box is being used, best practice is to insert a green grounding screw into the threaded hole in the back of the box or enclosure. The equipment-grounding wires then connect to the screw, making the metal box part of the grounding system.

How do you ground a metal box to a BX cable?



BX cable is grounded via its metal armor or internal green plastic-coated ground wire. Because vinyl is not conductive, grounding is achieved by a separate bare copper ground wire in the bundle. BX is cut with a hacksaw. Better yet, use a special armored cable cutting tool.

Can BX cable be used as ground?

Only BX which includes a bonding wire or bonding strip may be used as ground. Most “BX” style AC cable installed in the 30’s-60’s does not have the required strip. Using BX as a ground is extremely dangerous, because it is not a low impedance path to ground.

How do you connect armored cable to box?

Quote from the video:
Quote from Youtube video: Ahead of where you're stripping the cable off because that wire will go inside the box so anyway it'll work like. This that's all you need and then bingo in that slick.