Can you share neutral on the same circuit?

A multiwire branch circuit is a branch circuit with a shared neutral. This means there are two or more ungrounded (hot) phase or system conductors with a voltage between them and a shared neutral.

Is it OK to share a neutral?





as long as the phase conductors are on different “phases” it’s fine. Recent code requires them to be on a double pole breaker though. I do it as much as possible in houses. It’s easier to pull one three wire for two circuits, than 2 separate two wires.

Can 3 circuits share a neutral?

If it is a 3 phase circuit you can have 3 hots per neutral as long as you are using the A, B & C phases for each neutral. A neutral is a current carrying conductor and must be the same size as the hot.

Can you put 2 neutral wires together in a breaker box?

Double tapped neutrals can expand and contract enough to the point where the connection becomes loose. The loose connection could overheat and cause a fire. Check out these double tapped neutrals I found during an inspection. These connections loosened up over time causing arcing and overheating.

Can a neutral wire be overloaded?

If you’re talking about a single phase system, then remember the goes-ins equal the goes-outs. So, if your neutral is sized the same as your conductor (which is should be), and you overload the neutral, then your hot line is overloaded by the same margin.

How do you test for a shared neutral?





When the neutral is borrowed for the two way lighting in a domestic, you can see it by looking at the wiring of the upstairs 2 way switch; there will be two strappers from downstairs and a single switch line to the lighting point; no test required.

Can a GFCI share a neutral with another circuit?

You can’t share the neutral on the output of the GFCI. It must only go to the outlets being protected. If you try to share this neutral your GFCI will not work and will trip immediately. Keep this neutral completely separate from other circuits.

Can I tie neutrals together?

As these joined neutrals include the travelers of both three-way circuits, the neutrals from the nearest light to each box, and the neutral heading back to the panel from each box, these two circuits’ neutrals have multiple junction points that tie the neutrals together.

Can neutrals and grounds together?

The answer is never. Grounds and neutrals should only be connected at the last point of disconnect.

How do you fix a double lugged neutral?



A licensed electrician will be able to fix your neutral wires if they are double tapped by moving them around and fitting them correctly. If there aren’t enough holes/fittings for the amount of neutral wires, a licensed electrician will install a new neutral bus bar to fit them in correctly.

What does double lugged mean?

Double lugging (some say double tapping, although this is not an entirely accurate description) is when more than one wire is terminated under a screw or connector on a circuit breaker or fuse block. Most circuit breakers are only designed and UL listed for one wire per connection.

Why are there two neutral wires?

There are two black and two white wires in an outlet box because the outlet is in the middle of a series circuit, accepting power from another source and sending it on. Two cables are hot wires, bringing the power in and carrying it onward to the next. Two cables are neutral and do the same.