Should my ground and neutral have continuity?

Once the outlet is connected to the wires in the wall (or plugged in in the OP’s case) there will be continuity between ground and neutral because they are connected in your main breaker panel, but if the GFCI (or any other outlet) is just sitting on a table, they should not have continuity.

Should I have continuity between phases?

Each phase to phase must have a continuity if winding is OK. If any particular phase fails the continuity test, your motor is probably burnt.

What voltage reading do you get between the hot and neutral bus bars?





Each hot busbar carries 120 Volt potential when tested to Neutral or ground. 240 Volt potential exists between busbar A and busbar B. The reason each busbar carries 120 volt potential when tested to Neutral, but 240 volt potential when tested to other busbar, has to do with way transformer and the grid are structured.

What happens if hot wire touches neutral?

A short circuit happens when a “hot” wire (black) touches another hot wire or touches a “neutral” wire (white) in one of your outlets. When these two wires touch, a large amount of current flows, creating more heat than the circuit can handle, so it shuts off.

Should neutral and hot have continuity?

If you are testing from one of the phase wires on the load side of the main breaker with it off to the neutral you will get a reading if any of the branch circuit breakers are on and connected to loads. Turn off all of the breakers and check again it should read no continuity. It’s a new house.

Should there be continuity between neutral and ground in subpanel?

The feed for your sub panel comes from your main panel the grounded conductor neutral and grounding conductor equipment ground are connected in the main panel so measuring continuity in a sub is normal even when the grounded conductor is isolated from the box and the grounding conductor.

Should there be continuity between hot and neutral on a motor?





… hot to neutral and neutral to ground. A first year apprentice should already know that you will read continuity from hot to neutral through the motor windings themselves, and neutral and ground are SUPPOSED to be connected at the service, so of COURSE they would read continuity.

How do you check continuity between phases?

Quote from the video:
Quote from Youtube video: First we need to test continuity across the primary winding to do this take one probe and touch the h1 bushing and touch other probe to the h2 bushing.

Should a 3 phase motor have continuity to ground?

The windings (all three in a three-phase motor) should read low but not zero ohms. The smaller the motor, the higher this reading will be, but it should not be open. It will usually be low enough (under 30 Ω) for the audible continuity indicator to sound.

Does neutral wire carry current?

To sum up, a live wire carries the full load current, while a neutral wire carries some current, only when the loads are not balanced.

Can ground be used as neutral?



A ground is not a neutral period. The last thing you want is the chassis of your washer as a current carrying conductor. If your house has a bonded neutral and ground then it should be at only at one connector and that is your circuit breaker panel and nowhere else.

Should there be voltage between hot and ground?

To check if neutral and ground are switched, measure hot-neutral and hot-ground under load. Hot-ground should be greater than hot-neutral. The greater the load, the more the difference. If hot-neutral voltage, measured with load on the circuit, is greater than hot-ground, then the neutral and ground are switched.

Should there be continuity between positive and negative?

For those interested, the answer to my original question is NO – there should not be any continuity between the positive and negative battery terminals when the battery is unplugged (as this would indicate a short circuit!).

Can you check continuity with power on?



To measure continuity, the multimeter sends a small test voltage through the wire. The multimeter reads the value of the test voltage to determine if there is continuity. If the power is on, the multimeter cannot accurately read the test voltage.

Should neutral wire have voltage?

The neutral wire is often said to have zero voltage on it. If you touch that wire on a live system, however, you will often find out very quickly that technically having zero voltage is very different from meaning there is no electricity present.

Why do I have 120 volts on my neutral wire?

If you have a neutral wire removed from the neutral bus bar in your panel it is possible to see 120VAC on that wire if the circuit breaker for that circuit is turned on and there is a load connected to the circuit and load device is also turned on.

Why do I have 80 volts on my neutral?

Check voltage across each conductors. If you read 80V between the hot and neutral, and read 120V between the hot and ground. You have a malfunctioning neutral. If you read 80V between hot and both the neutral and ground your problem is with the hot conductor.

Should the neutral wire be hot?



Look for a disconnected neutral. To test whether you have a broken neutral, turn off everything in the circuit which has the hot neutral. If the neutral is then no longer hot, this confirms that a neutral is disconnected in the circuit.

Why would a neutral wire have power?

Neutral wire carries the circuit back to the original power source. More specifically, neutral wire brings the circuit to a ground or busbar usually connected at the electrical panel. This gives currents circulation through your electrical system, which allows electricity to be fully utilized.

How do you test a hot and neutral wire with a multimeter?

Quote from the video:
Quote from Youtube video: Range then connect black probe to the ground wire or any grounded object like a water pipe faucet bridge or a heating radiator. And finally touch the red probe to each exposed wire.