The NEC requires 30″ of space for any Panel, but it does come with a lot of exceptions. One is door swings you must be able to the door 90 degrees to access the breakers. Seconfd it requires 30″ but the panel does not have to be center of the space. Third panels can share the 30″ space.

How far can a subpanel be from the main panel?

The right feet would be between 4.5 to 5 feet.



The cable running from your main panel to the subpanel depends on the amperage rating. For instance, for a 30A panel, use a 10 AWG, three-wire conductor.

Where do you place a subpanel?





Quote from the video:
Quote from Youtube video: Video so go grab a cup of coffee and a pen and paper if you want to take a few notes along the way with me whenever. You're going to be adding a subpanel always add the largest panel that that is

Can you run a 100 amp sub panel off a 100 amp main panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

How many wires can be from the main panel to a sub panel?

A subpanel requires two hot wires connected to a 240-volt double-pole breaker in the main panel. It also needs a neutral wire and a ground wire. The cable used for this run is known as a “three-wire cable with ground.” The two hot wires, called feeder wires, will provide all of the power to the subpanel.

Can a subpanel feed another sub panel?

Answer: Yes. The main electrical service panel is where branch circuits originate. A branch circuit consists of the circuit conductors between the final over-current device protecting the circuit and the lights, receptacles and equipment supplied by the branch circuit.

Can a subpanel be installed outside?





You can do it — you’ll need a subpanel loadcenter in a NEMA 3R enclosure, though, as well as watertight conduit/raceway and fittings for the outdoor runs, which will be done using THWN in the conduits.

How high should a sub panel be mounted?

All electrical panels must have a minimum of 36 inches of clearance in front of the panel, 30 inches of clearance across the face of the panel, and a minimum of 78 inches above the floor from the top edge of the panel.

Does a subpanel need a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building.

Can you feed a 100 amp sub panel with a 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

Can I run a 100 amp sub-panel off 200 amp main?



Can you add a 100 amp breaker to your main panel? Yes you have 12 slots the double pole breaker will only take 2 slots.

How many receptacles can be on a 20 amp circuit?

The answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.

Does sub-panel wire need to be in conduit?

Re: Subpanel wire run



Individual THHN conductors must be run in conduit–either metallic or non-metallic, flexible or rigid. You could probably use SER instead, as long as it’s sheathed and contains four conductors: one for Leg A, Leg B, neutral, and ground.

What size conduit do I need for 100 amp sub panel?



What Size Conduit You Need for 100 Amp Service. A 100 amp service will need a minimum of 1.25 inches, schedule 40 or 80 PVC grey electric conduit.

What size wire is needed for a 50 amp sub panel?

6 AWG Wire

6 AWG Wire Used For 50 Amp Service.

What size wire do I need to run a sub panel?

The cable you run from the main panel to the subpanel also depends on the amperage rating. You can use 10 AWG, three-conductor wire for a 30-amp panel, but for a 60-amp one, you need 6 AWG wire. If you’re installing a 100-amp panel, you need 4 AWG copper or 2 AWG aluminum three-conductor cable.

What size wire do I need for 100 amp sub panel 100 feet away?



If you check the wire size chart (you have the link in the introduction), the #0 AWG wire (also known as 1/0 AWG wire) has 150 ampacity. That means that #0 AWG wire is the perfect size wire for 100 amp service 100 feet away.

What wire size do I need to go 100 feet for a 60 amp service to a workshop?

What size wire should I use for a 60 amp subpanel? You can get away with 6 AWG when you have a short run of wire, however, due to voltage drop, if you ever decide you want to go more than 100 feet then a 4 AWG is the size you should choose.

What wire size do I need to go 100 feet for a 100 amp service to a workshop?

For a 100 ampere circuit, the conductors will likely be required to be 3 AWG copper or 1 AWG aluminum.

How far can you run 100 amp service?

Most ampacity charts are up to 100 feet and go up one size of additional 100 feet. So, if using a 100amp breaker at the service side, then need to minimally size the wire accordingly and there are different rating for non burial, burial and in conduit Aluminum sizes will be larger than copper.

What kind of wire do I need for a 100 amp subpanel?



The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example. (Aluminum is often used for feeder cables because the cost is typically much lower than that of copper wires.)