How far can I run a sub panel from the main panel?

You must provide from 3 to 4 feet of clearance on all sides of the panel depending on the voltage to ground. You may not know this voltage, so it’s best to provide 4 feet. The panel must be easily accessible, so don’t install it too far above the floor; 4.5 to 5 feet is about right.

Can you feed a panel from the bottom?





Chief Moderator. Yes, you can bottom feed a panel.

Can I use any panel as a sub panel?

There’s no problem with having a main breaker in a subpanel. It’s required if your panel is in a separate building and has more than six breakers, but there’s nothing prohibiting it in any other case.

How do you hook up a subpanel to the main panel?

Quote from the video:
Quote from Youtube video: Cover then of course we're going to need our feeder wire coming from our main panel over to our sub panel and in this case we're going to be running three gauge copper.

What is the minimum distance between two electrical panels?

To be on the safe side, the working space and space around electrical equipment should always be clear per 110.26(A), if possible. As a basic rule, there should be at least 3 feet of space in front of all equipment with a 30 inch width as well as 6½ feet of headroom space.

Can you run a 100 amp sub panel off a 100 amp main panel?





Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A.

Can you install a service panel upside down?

Just about all modern electric panels can be mounted upside down, meaning that the main breaker is located at the bottom instead of the top.

Does a main breaker in a panel have to be on top?

In most installations, this larger breaker is located at the top of the panel, but depending on how the main service panel has been installed, it could be at the bottom, or even at one end of a panel mounted sideways.

How high should a sub panel be mounted?

All electrical panels must have a minimum of 36 inches of clearance in front of the panel, 30 inches of clearance across the face of the panel, and a minimum of 78 inches above the floor from the top edge of the panel.

Does a sub panel need a ground rod?



Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building.

Can you feed a 100 amp sub panel with a 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

What is code for electrical panel clearance?

The National Electrical Code [NEC 110.26 (A)(1&2)] requires a clear area for access and working in front of an electric panel that is 2.5 feet (30”) wide, 3 feet (36”) deep, and 6.5 feet (78”) high for a regular residential 120/240-volt panel.

Can two electrical panels be next to each other?



You can have panels literally side-by-side, with only enough space between them to prevent their covers from bumping into each other. If when you open one panel’s door, it covers the panel face next to it, that is not a problem.

How much space is needed around an electrical panel?

The space around electrical equipment should always be clear to be on the safe side. There should be at least 3 feet of space in front of equipment with a 30 inch width as well as 612 feet of headroom space.

What is the maximum height for an electrical panel?

Mounting Height



A height limit applies to mounting a panel box. The circuit breaker at the top of the box may not be higher than 6-foot 7-inches from the floor. A permanent platform must be below the panel box if the top circuit breaker exceeds this specific height.

What is the minimum required width of working space in front of an electrical panel that is 24 inches wide?

wide that contains over current devices, switching devices, or control devices, there shall be one entrance to an egress from the required working space not less than 610mm (24 in.) wide and 2.0m (6½ ft.)

How high does a breaker box need to be mounted?



Height. The minimum height for a circuit breaker box is 4 feet, though the ideal height is between 5 feet and 6 feet. The maximum height allowed for the circuit breaker box is 6 feet.

What is the NEC code for Panel height?

6 ft. 7 in.

NEC states that circuit breakers shall be installed so that the center of the grip of the operating handle of the circuit breaker, when in its highest position, will not be more than 6 ft. 7 in. above the floor or working platform.

What is code for a breaker box?

Electrical Panel Placement Restrictions



The National Electrical Code 110.26 states that breaker boxes, and electrical equipment in general, must be placed in areas that provide sufficient working clearance around them. More specifically, the breaker box needs 3 feet of clearance in front of it.