Can a subpanel feed another sub panel?

Can I run a subpanel from a subpanel? Generally speaking, yes. You could put a million subpanels in series, and by itself that wouldn’t be a code violation. The metal conduit can act as the equipment ground so a 4th wire is not required.

Can I have 2 subpanels?





You can add as many subpanels as you need providing the combined electrical demand is below 160 amps. If all the circuitry was operating at once, the electrical service could become overloaded. However, all combined circuitry would not likely be on at any given time.

Can I put 2 100 amp sub panels on a 200 amp service?

Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance, …

How many sub panels can you have on a 200 amp service?

200 AMP Service – Feeding 3 Sub-Panels – Wire Size and Set Up Help Needed.

Can you daisy chain electrical sub panels?

Answer: Yes.



A branch circuit consists of the circuit conductors between the final over-current device protecting the circuit and the lights, receptacles and equipment supplied by the branch circuit.

What is the 6 breaker rule?





The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.

Can a 200 amp panel feed another 200 amp panel?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

How many sub panels are allowed on a 100 amp service?

However, NEC prohibits more than 42 circuits, so you can only choose between 20-42 breakers for a 100-amp panel. Breakers or circuit breakers act as a switch for cutting off power from the main electrical supply.

How many breakers can a 60 amp sub panel have?

Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

Are tandem breakers legal?



Tandem breakers are safe and legal to use only when the panel is designed for them and only in the slots that accept tandem breakers.

Can subpanel be bigger than main panel?

if the subpanel’s main breaker is larger than the supply breaker, it has no effect. if smaller than the supply breaker, the subpanel’s main breaker protects the subpanel.

How far can subpanel be from main panel?

The right feet would be between 4.5 to 5 feet.



The cable running from your main panel to the subpanel depends on the amperage rating. For instance, for a 30A panel, use a 10 AWG, three-wire conductor.

Where should feeder wires to a subpanel be connected?



Quote from the video:
Quote from Youtube video: The wire. Into the sub panel from the main panel. So we'll be running our six gauge ground wire. And our feeder wire next this is three gauge like I mentioned earlier anything six gauge or smaller.

Can I add a subpanel to a 100 amp panel?

If you have older 60-amp or 100-amp main service, it is entirely possible that you will need a service upgrade to 150-amps or 200-amps before you are able to adequately power a new subpanel.

What cable do I need for 100 amp subpanel?

Want to know the short answer? A 100 amp sub panel wiring size requirement is #4 for copper wires and #2 for aluminum wires. Now, you may question what you should use for your wiring installation and what are the advantages and disadvantages of one wire type from another. We’ll discuss these issues below.

Does a subpanel need a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building. And yes, a sub panel in the same building as the main does not need a ground rod – only the ground wire.

Can you feed a 100 amp sub panel with a 60 amp breaker?



You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

Can you feed a 100 amp sub panel with a 50 amp breaker?

Just wire it up. There is no problem using a sub panel that can take more current than you will ever feed it. Points to note: The cable to your hot tub will be rated for 50A (not 100A); therefore you must not upgrade the breaker in your main panel to 100A.

How many circuits can I run off a 50 amp sub panel?

A single receptacle has a maximum power draw of 1.5-amps, so, only use 26 outlets at most for a 50-amp breaker (40-amps ÷ 1.5-amp = 26.67 outlets).

Can you use a main breaker panel as a subpanel?

There’s no problem with having a main breaker in a subpanel. It’s required if your panel is in a separate building and has more than six breakers, but there’s nothing prohibiting it in any other case.