What is toilet plumbing?

A toilet drain is an opening in the subfloor of your bathroom through which all the sewage from the toilet is passed. The bowl of the toilet connects to the drain opening via a piece of metal or plastic called a “flange” or “closet flange”.

What pipes are needed for a toilet?





The standard size for a toilet drain pipe is 3 inches in diameter, but drains up to 4 inches in diameter are sometimes used. Typically, 3-inch pipes carry the water to the toilet, but a 4-inch pipe may be used to move wastewater out of a house to a sewer or septic tank.

How are toilets plumbed?

The flapper hinges onto the vertical overflow pipe that’s next to the valve, and a small chain connects the flapper to the trip lever. The advantage of a flapper over the earlier stoppers is that it doesn’t have as many parts to foul or get hung up so it’s less likely to let the tank “run” or leak into the bowl.

What is the pipe behind the toilet called?

Tank: This is the back part of the toilet that holds the water used for flushing. It also houses the working toilet parts. Stop Valve: This controls the water supply to the toilet. It’s usually located on the wall behind the toilet.

How does a toilet work step by step?

Simplistically, the toilet works in three parts: The tank dumps two gallons of water into the bowl, starting the siphon. Through gravity, a siphon pulls waste and water down into the closet bend and out to the sewer. Then, the tank is filled up with fresh water, ready to flush again.

What are the parts of a toilet?





Toilet Bowl Parts

  • Lid: It covers the toilet seat and can act as a safety barrier. …
  • Seat: The toilet seat is attached to the bowl. …
  • Rim: The uppermost part of the toilet bowl, the rim runs around the top of the bowl. …
  • Toilet flange: This fitting seals the toilet to the floor and connects to the drain pipe.

How do you install a toilet waste pipe?

How to install a toilet pan connector

  1. What you may need:
  2. Step 1 – Cut out space for the pan outlet. …
  3. Step 2 – Fix down the WC pan. …
  4. Step 3 – Make the hidden connections. …
  5. Step 4 – Connect the connecting couple and the sewer pipe. …
  6. Your toilet should now be connected to the waste pipe.

Do toilets need to be vented?

“Does a toilet need a vent?” And the answer is yes, your toilet has to have a vent. For more information on the great importance of plumbing vents, read our plumbing vent article here. And the size of this vent pipe depends on your local plumbing code.

How do you run a toilet drain pipe?

Quote from the video:
Quote from Youtube video: And three inches on the outlet. Now normally the plumbing code never allows a drain to be reduced in size in the direction of flow like this however there's one exception.

How far should a toilet drain be from the wall?



The Distance To Set The Toilet Flange From The Back Wall. You’ll want to set the center of the water closet flange 12 inches from the finished back wall.

How many toilets can 110mm pipe take?

Requires two vertical stacks with horizontal connections from both sides, or one stack if toilets arranged over two floors, 32 total.

How deep does a toilet drain need to be?

For a standard 4-inch drain line, which is the typical size for a toilet drainpipe, the minimal drop is 1/4 inch per linear foot. That means that the pipe should drop an entire inch every 4 feet.

Does a toilet drain need to be sloped?



The plumbing code requires drain pipe to be sloped at a minimum of 1/2 inch per foot and a maximum of three inches per foot or vertical. A slope of less than a quarter-inch per foot will cause a lot of drain clogs and a slope of more than three inches will allow the water to drain.

How much space do you need under a toilet for plumbing?

Toilets and Bidets



Most codes require at least 15 inches (measured from the center of the toilet) from any side wall or obstruction and not closer than 30 inches center to center to any other sanitary fixture. (The NKBA actually recommends 32 inches.)

How long can a toilet waste pipe be?

IIRC it is permissible (but inadvisable) to go as low as 18mm per metre, the maximum is 90mm per metre. As long as the pipe have at least 15% downhill slop from Toilet to main waste pipe it would be ok. Any distance up to 3m do not require extra joining points as standard 4inch waste pipe is 3m long.

Can toilet waste pipe run under floor?

Soil pipes are generally located on an outside wall and enter the bathroom as close as possible to the toilet location. They can be mounted on the floor, but usually pipes run below the floor in-between the floor joists.

Does a toilet need a soil stack?



As the new w.c. appears to be at the head of a single line the answer is yes. The purpose of a vent stack is to save the trap from being pulled out with the outflow with the resulting problem of drain stench in the toilet.