Can multiple switches use the same neutral wire?

If both switches are powered by the same breaker you can wire both to the same neutral.

Do you need a neutral at every switch?





Neutrals. When wiring lighting circuits supplied by a grounded general-purpose branch circuit, the 2011 NEC now requires you to provide a neutral conductor at nearly every switch point [404.2(C)]. The purpose for this is to complete a circuit path for electronic lighting control devices, such as occupancy sensors.

Is it code to have a neutral in a switch box?

Quote from the video:
Quote from Youtube video: It. Says the grounded circuit conductor now you need to know that the grounded circuit conductor is the neutral the white neutral wire goes to the grounding bus bar and a main panel.

Can a neutral be run separately?

Even the NEC permits conductors of nonmetallic wiring methods in separate cables and conduits, and specifies no limitation on separation distance.

Can you put 2 neutral wires together in panel?

Bottom Line. Many homes have neutral bars that have too many neutral wires in one hole or slot. Generally this does not create a problem for the homeowner, however, it is an easy fix and most home inspectors recommend correcting the issue.

Can you mix neutrals from different circuits?





The grounding conductors all go together regardless of circuit, but the neutrals need to be separated.

Is it code to have neutral wire?

All switch locations need a neutral wire. This national electrical code was mainly implemented to accommodate potential future uses. Electronic switches require a small amount of constant electricity and therefore need a neutral wire run to them.

How do I run an extra neutral wire?

Quote from the video:
Quote from Youtube video: It's as simple as just pulling another wire down back through the conduit. And into the light switch.

Can you have a neutral at a light switch?

Count them. If there are two conductors and an earth in the switch then there is no neutral. One conductor will be permanent line and the other will be switched line. If there are three or more conductors and an earth in the switch then there is most likely a neutral.

Does NEC allow shared neutrals?



Sharing neutral or yoke



The NEC does not define multiple circuits. However, relating to 210.7, it appears to mean more than one circuit, on separate phases and each with its own neutral. If the circuits were on the same phase, simultaneous disconnection in the panelboard would not be possible.

Do parallel feeds have to be the same length?

All of the paralleled conductors in each phase, neutral or grounded set must be the same length and be made from the same conductor material. They must be the same circular mil area and have the same type of insulation. Finally, all parallel conductors must be terminated in the same manner.

Can you share a neutral on GFCI breaker?

“The only way to use two GFCI receptacles to provide GFCI protection to more than two total receptacles on a shared-neutral circuit is to stop sharing the neutral after the GFCIs – by using two seperate 12/2’s, or 12/2/2.

Can you double up neutrals on a neutral bar?



“Double tapped neutral” is a slang term used when 2 neutral wires (the white wires) are terminated under the same screw on the neutral bus bar. This has been an unacceptable practice for many years for a couple of reasons.

Can I add another neutral bar to a panel?

So the neutral bars have thermal considerations ground bars do not, as well as, you don’t want current to normally be present on the panel chassis, which is grounded. So you cannot add additional neutral bars, but they provided enough neutral slots for your needs, so you are all set.

Can you stack neutrals?

Furthermore, all neutral camps can be stacked indefinitely; as long as all the creeps have escaped the camp boundaries.

Can neutral and ground be on the same bus bar?

The answer is never. Grounds and neutrals should only be connected at the last point of disconnect. This would be at main panels only.

Can you tie neutral and ground together?



No, the neutral and ground should never be wired together. This is wrong, and potentially dangerous. When you plug in something in the outlet, the neutral will be live, as it closes the circuit. If the ground is wired to the neutral, the ground of the applicance will also be live.

What is a floating neutral?

iTechworld portable generators are “floating neutral”, meaning that the neutral circuit is not connected to the frame or to earth ground. This also means that both legs on the receptacle are hot legs, which is normal for floating neutral generators.

What is the difference between bonded neutral and floating neutral?

Quote from the video:
Quote from Youtube video: So I'm drawing some pictures real quick to show you the difference the bonded neutral generator on the top. Shows that the neutral is physically bonded to the external frame of the generator itself.

What happens if neutral is not connected?

If a neutral wire gets disconnected, then the appliances will not work, the fan may get burn, choke in the tube may burn, and current starts flowing through the neutral wire. If you insert the tester in the neutral point (socket) then it will indicate like a phase.