How do you connect copper pipes without soldering?

Press Fit Connectors. In press fit connections, a battery-powered press tool is used to connect fittings to pipes. With just a single press of a button, the tool clamps the fitting onto the pipe and makes a permanent, leak-proof connection. Press fit connectors share many of the same benefits as push fit connectors.

What is DWV copper fittings?





Copper DWV Pipe

The letters DWV stand for drain, waste, and vent—a helpful reminder that DWV pipe is approved for use only in drain and vent lines.

What is Type DWV copper?

Copper drainage tube is a seamless copper tube that conforms to the particular dimensions that are commercially known as Copper Drainage Tube, Type DWV. The characteristics of lightweight DWV grade copper tubing make it an excellent, durable choice for use in drain, waste, and vent systems.

Are copper press fittings reliable?

Copper press fitting is a flameless alternative to soldering copper pipe connections. In this system, a hydraulic tool is used to press specially designed connectors to join traditional pipes. These connectors house a sealing element that, when pressed, creates an even and reliable connection.

Can you repair a copper pipe without solder?





A simple alternative to soldering when a leak occurs somewhere along a run of pipe (not at a fitting) is to cut out the damaged section and splice in a compression repair coupling. These cut-and-paste couplings are commonly available for 1/2- and 3/4-in. -dia.

Can you use SharkBite on copper?

SharkBite brass push-to-connect fittings are compatible with PEX, Copper, CPVC, PE-RT and SDR-9 HDPE pipe. SharkBite fittings come with a PEX stiffener pre-loaded into the fitting for PEX, PE-RT and SDR-9 HDPE. The PEX stiffener does not need to be removed for Copper or CPVC applications.

What color is DWV copper pipe?

Table 14.1. Copper Tube: Types, Standards, Applications, Tempers, Lengths

Tube type Color code Commercially available lengths 2
Nominal or standard sizes
DWV Yellow 1-1/4 inch to 8 inch
ACR Blue Straight lengths:
1/4 inch to 4-1/8 inch

What is the main difference between Type L and Type ACR copper tubing?

Type L copper is typically sold in straight lengths. ACR tubing is typically sold in a coil. Identify whether there are rubber or plastic caps on the end of the tubing. ACR is designed to be sold with no moisture inside the tube.

What is ACR copper pipe?



Copper tube for air-conditioning and refrigeration field service (ACR) is designated by actual outside diameter. “Temper” describes the strength and hardness of the tube. In the piping trades, drawn temper tube is often referred to as “hard” tube and annealed as “soft” tube.

Do ProPress fittings leak?

In general, Viega Propress fittings only leak due to one of three reasons; the fitting was never pressed, the copper tubing was not properly inserted or the pressing jaws were not properly aligned. If the fitting was never pressed, confirm that the tubing is properly installed and proceed with pressing.

How long do ProPress copper fittings last?

How long will ProPress last? Re: ProPress Longevity? the Viega company offers a 50 year warranty on ProPress fittings. Uponor’s aquaPEX is 25 years.

Is ProPress better than SharkBite?



ProPress VS Sharkbite

Both systems rely on EPDM o-rings. ProPress is only better because the pressing of the copper fitting against the copper pipe is a stronger and more reliable hold than the stainless teeth on the sharkbite.

Can you ProPress soft copper?

ProPressG is approved for use with hard copper tubing from ½” to 2″ and soft copper tubing in ½” to 1¼” diameters. All tubing must comply with ASTM B88 standards.

Are ProPress fittings reliable?

While the ProPress system is one of the most consistently reliable fittings on the market, the Smart Connect feature provides additional peace of mind.

Can ProPress fittings be soldered?



Can you solder next to ProPress fittings? Yes. When soldering next to ProPress fittings, the installer must remain at least three tube diameters away from the connection to prevent damage to the sealing element.

Can you sweat ProPress fittings?

Yes you can…. No you shouldn’t. If your machine craps out, then pretend you never heard of pro-press and get the right fitting. And yes, that may mean leaving the water off longer than you planned.

How much pressure will a ProPress fitting hold?

The ProPress System meets the most rigorous testing standards and codes in the United States, Canada and Europe. In tests conducted by NSF International, joints made by the ProPress System have rated test pressures of 600 psi, and working pressures of 200 psi within an operating temperature range of 0° to 250° F.

Can you’re crimp copper fittings?

Even though the crimp rings can’t be used again, the fittings can be when removal is done correctly and the fitting is in good shape. So before throwing the whole fitting away, consider following these steps to remove the copper crimp ring and reuse the fitting.

Who makes ProPress fittings?



Viega ProPress

The #1 press fitting in the industry. Available in sizes ½” to 4″.