How far can I run 12 gauge wire on a 20 amp breaker?

You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

How far can you run 12 gauge wire without a voltage drop?





As an example, for a 120-volt circuit, you can run up to 50 feet of 14 AWG cable without exceeding 3 percent voltage drop.
For 240-volt circuits:

14 AWG 100 feet
12 AWG 120 feet
10 AWG 128 feet
8 AWG 152 feet
6 AWG 188 feet

Apr 30, 2021

How many amps can 12 2 wire carry?

20 amp

Maximum Breaker Size is 30 amps. You can use a 20 amp circuit breaker with 12/2 Romex as 12/2 wire is rated for 20 amps.

What size wire do I need for a baseboard heater?





In total a standard 12 gauge awg should be used for wiring electrical heat circuits. This is used for residential and commercial applications. Always refer to the electrical code for wire sizes. Most all baseboard heaters require 12 gauge as it is reliability available.

What size wire do I need to run 400 feet?

Example calcuation 2 – Copper Wire, 3 Phase power

Cable run: 400 ft.

How far can you run 12 volt wire?

12V DC Power Drop / Max Cable Distance Chart

24 AWG 12 AWG
DC 100mA 216 feet 3,508 feet
DC 200mA 108 feet 1,755 feet
DC 300mA 72 feet 1,169 feet
DC 400mA 54 feet 877 feet

How far can you run 12 2 wire on a 30 amp breaker?



Yes, based on the National Electric Code or NEC, you can use 12-2 AWG cables for THHN or THWN-rated wires. These cables are made for general purposes and can hold up to 194 degrees without taking any damage. It simply means these wires can withstand the heat temperature drawn by a 30 amp circuit breaker.

What is the maximum length of under ground cable recommend?

Therefore, it imposes a serious limitation in the length of AC underground cables. For example, practical transmission length for a 138 kV, XLPE cable is limited to 66 miles [1]. This paper proposes using AC underground cables for a distance slightly longer than the electrical half-wavelength.

What size wire do I need to run 300 feet?

for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit, …

What is 20amp wire?



Why Wire Gauge Is Important

Wire Use Rated Ampacity Wire Gauge
Low-voltage lighting and lamp cords 10 amps 18-gauge
Extension cords (light-duty) 13 amps 16-gauge
Light fixtures, lamps, lighting circuits 15 amps 14-gauge
Kitchen, bathroom, and outdoor receptacles (outlets); 120-volt air conditioners 20 amps 12-gauge

How many heaters can you run on a 20-amp circuit?

A 20-amp breaker can support any combination of heaters up to a total of 3,840 watts. For example, using a single thermostat, the breaker could support two 1500-watt heaters or three 1000-watt heaters.

What size wire do I need for a 240 baseboard heater?

A 240-volt baseboard heater requires its own dedicated 20-amp or 30-amp 240-volt electrical circuit. A 20-amp circuit can safely provide 3,800 watts of power, while a 30-amp circuit is suitable for up to 5,700 watts. The standard circuit cable for 20-amp circuits is 12-gauge cable; 30-amp circuits need 10-gauge cable.

Can I use 12 2 wire 220v?

The same 12-gauge wire can be used for a 220v, 20-amp outlet to run power tools. … You need a different type of receptacle and 10-gauge cable if the appliance draws 30 Amps.

Can I use 12 gauge wire 220?



If you’re wiring a 220v, 20-amp outlet to run power tools, you can use the same 12-gauge wire you would use for a 110-volt, 20-amp circuit. Remember that the cable must have an extra hot wire. If the appliance draws 30 amps, you need a different type of receptacle, and the cable needs to be 10-gauge.

How many 240V baseboard heaters can I put on one circuit?

If we have a 240V circuit, we can connect up to three 1,500 W baseboard heaters.

Can you put 2 baseboard heaters on the same circuit?

All heaters must be wired in parallel. You can either do that by connecting each heater to the thermostat directly, or by connecting each heater to the next — just be sure that each heater is connected to the source wires.

How many watts can a 20-amp breaker handle?

2,400 watts



20-amp 120-volt circuit: 20 amps x 120-volts = 2,400 watts.

Can you put 2 baseboard heaters together?

Things You’ll Need

In most all cases, multiple baseboard heaters can be connected together if the total operational amperage does not exceed the wires and circuit breaker’s capacity. If the heater is too large it must be wired on a separate circuit.

How many baseboard heaters can you have on a circuit?

A circuit running on a 20-amp double-pole breaker can have any combination of heaters up to 3,840 watt. You can install two 1,500 watt heaters if you use just one thermostat. There are three 1,000 watt heaters.

How many amps is a baseboard heater?

Manufacturer’s Recommended Heating Needs

Total Area of Room (sq. ft.) Recommended Heater Rating (watts) Electrical Circuit Size Needed (240 volts)
300 2700 15 amps
400 3600 20 amps
500 4500 30 amps
800 7200 40 amps