Cutler-Hammer Type BR/C and Connecticut Electric are your trustworthy substitute breakers for Challenger panels.

Will a GE breaker fit in a Challenger panel?

If you have a Challenger system, however, you need to arrange a panel upgrade. If your Challenger model is no longer made, circuit breakers can be replaced with several compatible brands, including GE.

Should Challenger breakers be replaced?





Challenger electrical panels are no longer available because they do not meet today’s UL safety standards. If you still have a Challenger box in your home, you should consider getting the panel replaced.

Does challenger still make breakers?

Fortunately the Challenger products in question are no longer manufactured. In fact, Challenger is no longer in business; the remaining product lines were acquired by Eaton/Cutler Hammer.

Are all 20 amp breakers the same?

Obviously, the answer is no. Unlike most electrical devices like switches and outlets, circuit breakers are brand specific. In fact, the manufacturers will tell you to only replace or add breakers specifically designed for that brand panel. Even more, only use the type of breaker recommended for the panel.

What breaker is compatible with challenger breakers?

Cutler-Hammer Type BR/C and Connecticut Electric are your trustworthy substitute breakers for Challenger panels.

Can you use Eaton breakers in a Challenger panel?





Since the Challenger breakers are dangerous, every breaker in your panel needs to be a Type BR/Type C from Bryant, Cutler Hammer or Eaton.

Who owns Challenger breakers?

Cutler Hammer

The Challenger mark is owned by American Circuit Breaker Company, which makes aftermarket FPE breakers for small breakers. After the sale of the Challenger division to Westinghouse, the switchgear end of things ended up being bought out by Cutler Hammer.

What is wrong with challenger electrical panels?

Challenger panels posed safety hazards very similar to that of Zinsco. The biggest concern for Challengers were their issue with overheating. In turn, that can cause many other issues, like fusing and/or melting, corrosion, or actual fires. Occasionally they don’t trip at all, or just may take too long to trip.

What brand of breakers are interchangeable?



UL Classified breakers are designed and tested to be both mechanically and electri- cally interchangeable with circuit breakers manufactured by General Electric, Thomas & Betts, ITE/Siemens, Murray, Crouse-Hinds, and Square D.

Which breakers are interchangeable?

Specified breakers are breakers that have been tested and listed for a panel by the manufacturer. Interchangeable breakers are breakers that have been tested in the panels that they are approved for and are similar to specified breakers, typically by a third party such as Underwriter’s Laboratory (UL).

What is 20Amp wire?

Why Wire Gauge Is Important

Wire Use Rated Ampacity Wire Gauge
Low-voltage lighting and lamp cords 10 amps 18-gauge
Extension cords (light-duty) 13 amps 16-gauge
Light fixtures, lamps, lighting circuits 15 amps 14-gauge
Kitchen, bathroom, and outdoor receptacles (outlets); 120-volt air conditioners 20 amps 12-gauge

What wire should I use for 20 amps?



12 AWG

A 20 amp breaker requires a wire size of 12 AWG. This is the smallest wire size you should use for a 20 amp circuit breaker since an AWG gauge of 12 represents 20 amps.

What needs a 20 amp circuit?

Large consumers, especially kitchen appliances, such as microwaves, blenders and toasters, need a dedicated 20 amp circuit, to ensure a constant energy flow, which means they cannot share the circuit with other devices.

What size wire do you need for 20 amps?

Twelve-gauge wire



β€œTwelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and β€œThe circuit breaker or fuse is always sized to protect the conductor [wire].”

What Romex do I need for 20 amp circuit?

12 gauge Romex is rated for 20 Amps and is commonly yellow jacketed.

What happens if you use 14 gauge wire on a 20 amp circuit?

I would say 14 gauge wire anywhere on a 20 amp circuit is not OK. The purpose of the breaker is to cut off power before the wiring overheats. If you plug in several devices on an outlet that total 20 amps, you will exceed the safe working capacity of the 14 gauge wire without tripping the breaker.

Can I use a 20 amp breaker with 14 gauge wire?

14 AWG can’t be used on a circuit with a 20A breaker. The screw terminals are the better choice if you want to put 15 Amp receptacle on a 20 Amp circuit with 12 gauge wire.

Can 12 gauge handle 20 amps?



The next size larger is 12-gauge wire, which can carry up to 20 Amps. The wire size that has been chosen affects the Amp rating of a circuit breaker. A 20-amp breaker is not allowed to run circuits with 14-gauge wires.

Can I switch a 15A breaker with 20A?

The answer: It’s possible, but not advisable without an electrician evaluating the situation. You should never just upgrade from a 15-amp breaker to a 20-amp one just because the current one is tripping. Otherwise, you may burn your house down via electrical fire.