What kind of breaker do I need for a garage heater?

For a 26A nameplate load, Code will require #8 wire and a 40A circuit breaker. There really isn’t any legal way around it.

What size wire do I need for a 240-volt garage heater?





Sizing the Heating Circuit

AMPS VOLTS WIRE SIZE ALUMINUM
24 240 #8/2
32 240 #6/2
41 240 #4/2
52 240 #3/2

What size breaker do I need for a 240-volt heater?

Electricians generally install 240-volt heaters, since they use lower amperage and are more energy-efficient than 120-volt heaters. Adding a 240-volt baseboard heater usually requires a new 20- or 30-amp double-pole circuit breaker and new circuit wiring to supply one or more heater units.

What size breaker do I need for a 5000W garage heater?

If it’s 5000W , then you’re OK with 10guage on 30A breaker.

How many heaters can you run on a 20 amp circuit?

If you use 240V baseboard heaters, the 20-amp circuit can support a net total of 4,800 W. That’s two 2,000 W baseboard heaters or three 1,500 W baseboard heaters. In short, a 20-amp circuit can handle anywhere from 2,400 W to 4,800 W of baseboard heater electric power input.

Does a garage heater need its own circuit?





In a residence the heater/furnace require a dedicated breaker in a garage heater application this is not required. You need to wire it with a switch and armour BX 14/2 wire. Splicing in an extension cord to a wall plug is not to code. Splicing in an extension cord to a wall plug is not to code.

How do you wire a 240 volt garage heater?

Quote from the video:
Quote from Youtube video: This is actually just a fancy name for a relay. It's a 30 amp contactor there's a coil inside here that runs off 120.

How many heaters can you run on a 30 amp breaker?

The number of heaters you can attach to one thermostat also depends on your circuit and wiring

Volts Size of breaker Maximum watts on circuit
240 20 Amp Double Pole 3840
240 30 Amp Double Pole 5760


How do you wire a 240 volt wall heater?



Quote from the video:
Quote from Youtube video: So this heater has some screw terminals very here and here so on 240 volts you have your two lines. And your ground that's it so we go one of our wires.

How do you wire a 5000 watt garage heater?

Quote from the video:
Quote from Youtube video: You figure out that the draw for this heater is 21 amps so a 30 amp breaker is plenty the green ground wire will attach to the ground bar in the panel.

What size wire do I need for a 4000 watt heater?

Hi Martin – A 4000 watt 240 volt wall heater will require about 16.6 amps. Although a 12/2 wire is rated at 20 amps it would be best to install a 10/2 wire for a 4000 watt 240 volt heating unit. This would ensure that the circuit is safely loaded at 80 % of the capacity of the wire.

What size breaker do I need for a 6000 watt heater?



If you have a heater that uses a total of 6000 watts in a 240 volt connection, you’ll need a minimum of 25 Amps. However, because the system will use all 25 Amps, it’s safer to get a circuit breaker of 30 Amps.

How many watts can I run off a 20 amp breaker?

Now, a 20 amp breaker generally can support 2,400 watts per single circuit.

How many heaters can I put on one circuit?

A circuit running on a 20-amp double-pole breaker can have any combination of heaters up to 3,840 watt. You can install two 1,500 watt heaters if you use just one thermostat. There are three 1,000 watt heaters.

How many watts can a 30 amp breaker handle?

3,600 watts



The formula is 30 amps X 120 volts = 3,600 watts.

How far can you run 12 gauge wire on a 20 amp circuit?

After these distances, the circuit will go over the recommended 3% voltage drop. You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

What size wire should be used with a 30 amp breaker?

10

30 AMP Wire Size



For a maximum of 30 amps, you’ll need a wire gauge of 10. The most common household item that requires a 30 amp circuit is a central air conditioner.

Can 12 gauge handle 30 amps?



Can You Use a 30-Amp Breaker on 12-Gauge Wire? You should not use a 30-amp circuit breaker on a 12-gauge wire. The circuit breaker installed on a circuit is of a specific size to protect a certain wire gauge. A larger breaker on a thinner wire will allow more current over the wire before tripping.

How far can you run 12 2 wire on a 30 amp breaker?

Yes, based on the National Electric Code or NEC, you can use 12-2 AWG cables for THHN or THWN-rated wires. These cables are made for general purposes and can hold up to 194 degrees without taking any damage. It simply means these wires can withstand the heat temperature drawn by a 30 amp circuit breaker.

How many amps can you run on 12 gauge wire?

20 amps

“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”