Use #8 THHN wire for a 50-amp sub-panel or #2 THHN wire if the sub-panel is 100 amps. Run the wire from the main panel to the sub-panel box. Run black, red, white and green wires from the sub-panel box to the main panel box. If the weather is cold outside, keep the wire inside to keep it warm.

What is a good size sub panel for garage?

A 100-amp subpanel in a detached garage may be enough to handle high-draw appliances such as refrigerators. As for basic lighting or low-load electronic devices, a 50- or 60-amp subpanel in a detached garage may suffice.

What size wire do you need for a subpanel?





The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example. (Aluminum is often used for feeder cables because the cost is typically much lower than that of copper wires.)

What size wire do I need to run to my garage?

In general, you need 10-gauge wire for a 30-amp subpanel, 8-gauge for a 40-amp one and 6-gauge for a 50-amp subpanel. If you need a 100-amp subpanel, you’ll be running beefy 3- or 4-gauge cable with a 6-gauge ground wire. Voltage drop becomes an issue over distances in excess of 100 to 150 feet depending on cable size.

What size wire do I need to run a 60 amp subpanel?

In short, the wire size for a 60 amp sub-panel 150 feet away is 3 AWG gauge wire.

How big of a subpanel can I install off a 100 amp service?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

Does a garage subpanel need a main breaker?





A main breaker on a sub-panel is not necessary because this is in the same building (if you are in a different building then NEC 225.31, 225.32, 225.33 apply). That said, having a main breaker in the sub-panel is also acceptable.

What size wire do I need for 30 amps at 200 feet?

In most cases, you will need an #8 AWG wire for a 30 amp 240V circuit. The key for 30 amp wire sizing is to account for 2 NEC codes, namely: NEC 220-2 Code. This requires that a conduit wire’s maximum load (30 amps) represents 80% of ampacity of that wire.

Can you feed a 100 amp sub panel with a 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

What wire size do I need to go 100 feet for a 100 amp service to a workshop?

For a 100 ampere circuit, the conductors will likely be required to be 3 AWG copper or 1 AWG aluminum.

What size wire do I need to run 60 amps 100 feet?



What size wire should I use for a 60 amp subpanel? You can get away with 6 AWG when you have a short run of wire, however, due to voltage drop, if you ever decide you want to go more than 100 feet then a 4 AWG is the size you should choose.

What size wire do I need to run 60 amps 200 feet?

For 60 ampere breakers, electricians and professionals suggest using a wire size gauge ranging from 6 AWG to 4 AWG. All household wires have a rating of at least 600V, so only amperage really matters when it comes to determining wire gauge. Therefore, the wire size for 60 amp 220v, for example, is still 6 to 4 AWG.

How many amps can 6’2 wire carry?

RULES OF THUMB



“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”

How do you wire a sub panel in a garage?




Quote from Youtube video: If you're doing a sub panel. You want to make sure the power is off got my wire going to power the outlet. And two switches. And then i've got my 10 2 wire. That's coming from the main panel.

Can I run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

How many circuits can be on a 60 amp subpanel?

Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

Does a subpanel need a separate ground?

The biggest difference between a subpanel and a main panel is that the ground and neutral buses on a subpanel have to be separated. Most panels come with a bar joining the two, which is easily removed. Code requires subpanels to have a ground connection that’s independent of the main panel’s.

How many amps will trip a 60-amp breaker?



If it’s located on the higher side of the panel, expect a reduction of at least 5 amps in its total capacity. Don’t forget how long the electrical load lasts. The longer the load lasts, the sooner the breaker trips. Take note that it only takes 3 minutes of continuous 60-amp load to trip a 60-amp breaker.

Can I put a 50 amp breaker in a 60-amp subpanel?

You can put the GFCI breaker in the main panel, and protect every circuit in the subpanel just like that. That would also allow you to use one of GE’s “double-stuff” 2-pole 50A breakers, that is only 1″ tall, leaving you 2 spare half-spaces in the panel.

How many circuits can a subpanel have?

The subpanel will contain about four to twelve breaker slots. It’s supplied with a 240V circuit breaker from the main panel. In this case, the main panel is referred to as the feeder breaker. However, a 200amp subpanel can be connected to a 200amp feeder panel as long as the load is 160amps or less.

How many circuits can you put on a 50 amp sub panel?

A single receptacle has a maximum power draw of 1.5-amps, so, only use 26 outlets at most for a 50-amp breaker (40-amps ÷ 1.5-amp = 26.67 outlets).