150 Foot Run – A 120-volt circuit on a 20 amp breaker will require 6/2 AWG wire for 150 feet.

What size wire do I need to run 150 feet?

150 Foot Run – A 120-volt circuit on a 20 amp breaker will require 6/2 AWG wire for 150 feet.

What size wire do I need to run 100 amps 150 feet?





2/0 AWG wire

Wire Size For 100 Amp Sub Panel 150 Feet Away
100 amp service 150 feet away from the sub panel requires #00 AWG wire (also known as 2/0 AWG wire). This wire has a median ampacity of 175 amps; more than enough than the required minimum 162.5 ampacity.

What size wire do I need to run 50 amp service for 150 feet?

No. 4 AWG

To run 50 amps at 150 feet, you can use No. 4 AWG. The larger the wire diameter is defined by the smaller numbers on a wire.

What size wire do I need to run a 100 amp service 200 feet?





To feed a 100 ampere secondary panel 200 ft. from the main panel, you’ll want to use 1 AWG copper or 2/0 aluminum conductors. This is large enough to safely carry 100 amperes, and to maintain power quality over the distance.

What gauge wire do I need for 100 amp service?

Installation of 100 amp electric service or subpanel needs a #4 AWG copper wire or #2 AWG aluminum or copper-clad wire inside a minimum 1.25 inch, schedule 40 or 80 PVC electric conduit for underground service.

What size wire do I need for a 100 amp underground service?

For 100 AMP service, you’ll need a #4 AWG copper wire or #2 AWG aluminum or copper-clad wire. Make sure to limit your voltage drop to 3% regardless of distance.

Will #2 wire fit in a 100 amp breaker?

A 100 amp sub panel wiring size requirement is #4 for copper wires and #2 for aluminum wires.

How far can you run #2 aluminum wire?



400 ft.

Example calcuation 2 – Aluminum Wire, 1 phase power
Cable run: 400 ft. 1 conductor per phase utilizing a 1000 kcmil Aluminum conductor installed Direct Buried will limit the voltage drop to 2.61% or less when supplying 194 amps for 400.0 feet on a 240 volt 1 phase system.

What size wire do I need for 100 amp service 100 feet away?

A 100A breaker would require a #8 cu or a #6 al. If you are calculating full load then the grounding conductor must take voltage drop into account and rise a full two sizes more just like the current carrying conductors or a #4 cu or #2 al.

What size is 200 amp service wire?



For a 200 amp service, you’ll need: #2/0 copper wire, or. #4/0 aluminum or copper-clad aluminum wire.

What size wire do I need for a 200 amp underground service?

Installation of 200 amp electrical service needs a #2/0 AWG copper wire or #4/0 AWG for aluminum or copper-clad wire inside a minimum of 1.5 inches, schedule 40 or 80 PVC conduit for underground service. However, 2 or 2.5 inches is recommended if running 3 wires in the same conduit.

Can I run a 100 amp sub panel off 200 amp main?

Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance, …

How far can subpanel be from main panel?

The right feet would be between 4.5 to 5 feet.



The cable running from your main panel to the subpanel depends on the amperage rating. For instance, for a 30A panel, use a 10 AWG, three-wire conductor.

Can a main panel be used as a subpanel?

There’s no problem with having a main breaker in a subpanel. It’s required if your panel is in a separate building and has more than six breakers, but there’s nothing prohibiting it in any other case.

What’s the difference between a sub panel and a main panel?

The main panel is directly connected to the point of entrance to a building, and all sub-panels feed off that connection. However, the sub-panel provides a useful methodology for installing outlets that help you organize your electrical system into something more manageable.

What’s the difference between main panel and subpanel?

A main panel is an installed box where the power from the utility company enters the premises. A subpanel is an installed features that acts as a middle ground for the main panel and other types of circuits that are connected to your property.