The PVC vent pipe connects to a PVC flue pipe at the top of the furnace unit. An electric-powered fan forces the exhaust gas from the furnace chamber into the PVC flue pipe and drives the exhaust gases outdoors.

What are the different types of vent pipe?

Types of Venting Pipe

  • Stove Pipe.
  • Chimney Pipe.
  • Pellet Vent.
  • Direct Vent.
  • Type B Gas Vent.
  • AL29-4C Special Gas Vent.
  • Venting Kits.
  • Chimney Liners.





What is Type B gas vent pipe?

AmeriVent Type B gas vent uses a double wall of metal pipe for insulation and safety. The inner pipe of reflecting aluminum heats quickly, containing the warm flue gases inside. The airspace between the inner and the outer pipes provides insulation against heat loss to keep the warmer flue gases on the rise.

What is Type 3 vent pipe?

Category III is defined as a gas heating appliance with a flue loss equal or greater than 17% (non-condensing) with a positive vent static pressure. In a Category III venting system, if there is a leak in the venting system, flue gas will flow from the flue pipe into the space.

What are the two pipes coming out of my furnace?

Direct-vent (two-pipe) system: The two-pipe system is most common in home heating applications. It provides a direct intake vent that brings outside air to the sealed combustion chamber with one pipe, while a second vent pipe provides sealed venting of exhaust gases back to the outside of your house.

What is the difference between Type A and Type B vent pipe?





Definition of Vent or chimney vent or flu vent: A metal chimney which is “thin walled” – either a single wall of metal or a thin double wall in some areas is called a “vent”. A double-walled metal flue used for venting gas fired appliances in the U.S. and Canada is a Type-B vent.

What type of PVC pipe is used for furnace exhaust?

Quote from the video:
Quote from Youtube video: So the local installers went and they found whatever material they could find readily. Available on the east coast they use standard pvc pipe like this this is drain waste and vent pipe that you'd see

What does B vent look like?

Quote from the video:
Quote from Youtube video: Well B vent fireplace is usually an open fireplace. So that it's not fixed. It's going to pull room air for combustion.

What is Type L gas vent?

Type L vents are designed for venting approved oil-fired and natural-gas appliances that produce draft hood flue gasses that do not exceed a temperature of 570º F (299º C), or 926º F (299º C) for 10 minutes in an over-fire situation. The minimum clearance from combustible materials is generally 3 inches.

Can you use B vent for oil furnace?



Furnaces with positive pressure and those that burn oil cannot use B-venting. Condensing appliances, such as type IV positive-pressure furnaces, cannot use B-venting. The metal of the vent and the water from condensation can eventually lead to problems in the line.

What is this pipe sticking out of my house?

If you’ve noticed a pipe leading to the outside of your home that drips water, there’s a good chance that this is actually just your AC condensate drain, which is supposed to carry water outside your home.

What is PVC vent pipe?

A plumbing vent pipe works alongside your drain pipes, except it doesn’t carry water. Instead, it regulates the air in your plumbing system. Also called a vent stack or plumbing air vent, the vent pipe regulates airflow to assure waste and water flows through pipes that drain out of your house.

What is furnace flue pipe?



The flue pipe is a duct pipe that vents, or exhausts, gases from inside the home to the outside. A byproduct of combustion contains carbon monoxide and other dangerous compounds.

What is better B vent or direct vent?

A B-vent must be vented vertically and uses fresh air from inside the home to provide oxygen to the fire. A direct vent has a sealed glass front and pulls all of its fresh air from outside the home. Direct vents can be vented vertically or horizontally through an exterior wall.

How do you connect a Type B gas vent pipe?

Quote from the video:
Quote from Youtube video: Simply find any one of the four dimples and align it with any one of the four notches. Slide together until seated rotate 90 degrees until it stops the connection will now be locked.

What class is B vent?

Category 1 appliances



The Category is actually applied to the appliance. The Category is actually applied to the appliance. B-vent is ONLY allowed on Category 1 appliances unless the appliance manufacturer has specifically certified a particular B-vent system to be used alternatively.

What is Type PL vent pipe?

PL vent pipe is double wall pipe; the stainless steel inner pipe that carries the exhaust products is separated from the outer wall by an air space. Pipe joints must be sealed gas tight to prevent exhaust products moving through the vent under pressure from leaking into the home.

Are different brands of B vent compatible?

Metal-Fab B-Vent connects easily to other brands. You don’t need anything else! Mating two different brands of B-Vent doesn’t have to cost you time and money – Metal-Fab B-Vent connects to competitive brands in only TWO EASY STEPS!

What type of BH vent is CPVC?

Type BH Class 11B vent



System 636® CPVC is approved as a Type BH Class 11B vent and is designed for negative or positive pressure venting of gas-fired appliances with Flue Gas temperatures up to 194oF (90oC).

What type of BH vent is polypropylene?

ECCO Polypropylene Vent™ is a vent system for type BH gas venting, for use with ANSI Category II and IV gas burning appliances (condensing boilers) with a maximum flue gas temperature of 230°F (110°C).

What is UL 1738 vent pipe?

– UL 1738 is a standard for Venting Systems for Gas-Burning Appliances, Categories II, III, and IV. – It covers both metallic and non-metallic materials and includes over 50 material and system performance tests.