What can happen if extra long refrigerant line sets are used?

Liquid lines that are too large cause one of two problems: overcharge or undercharge. Liquid lines rob refrigerant from the system. Any refrigerant that is in the liquid line is doing nothing for the cooling or heating process.

Can a bad compressor cause high head pressure?





Some of these, such as a bad TXV or clogs in the refrigeration system are cited as the most common causes of high compressor head pressure.

What causes high head pressure in a refrigeration system?

Once the air gets to the condenser, it will remain at its top and not condense. The subcooled liquid seal at the condenser’s bottom will prevent the air from passing out of the condenser. This air and water vapor will take up valuable condenser surface area and cause high-head pressures.

What causes high head pressure and high suction pressure?

Worn compressor rings occur when the discharge gases leak through the compressor’s piston rings. This produces a lower head pressure during the compression stroke in the system. The suction pressure is elevated because the discharge gases have leaked through the rings. The result is higher than normal suction pressure.

Do I need to remove refrigerant if I cut my line set?

The answer is sometimes, yes. You want the right amount of refrigerant. It’s like the Goldilocks rule.

How long can you run AC line set?





Maximum equivalent length of line set is: a. 250 feet for single stage units with scroll or reciprocating compressors. b. 150 feet for single stage units with rotary compressors.

What are the symptoms of a bad TXV?

Bad TXV valve symptoms

  • There is frost on the evaporator.
  • Your unit is blowing warm air.
  • The AC compressor is running constantly.


What issues could cause excessively high condenser head pressure?

Causes of high head pressure

  • Overcharging of the refrigerant in the system.
  • Operating the system at high range than the specified limit.
  • Malfunctioning of the condenser fan motor.
  • The system is charged with the impurities of non condensing gases.
  • The condenser coil is not cleaned well.
  • Refrigeration device plugged.



Can a dirty air filter cause high head pressure?

Quote from the video:
Quote from Youtube video: All right so let's talk about one of the most. Common. Miss diagnosis that technicians get her confusions that they have about restrictions a common thing the techs. Believe is that if you have a

Will low refrigerant cause high head pressure?

The excess refrigerant will accumulate in the condenser, causing high subcooling and high head pressures. If a TXV receiver system is restricted in the liquid line, most of the refrigerant will accumulate in the receiver, with a bit in the condenser. This will cause low subcooling and low head pressure.

What causes high subcooling?



High Subcooling is an indication that more than the designed amount of refrigerant is “backing up” or “packed” into the condenser. This can be caused by overcharge, restriction (such as a contaminated line drier or kinked liquid line), or an undersized or failing closed metering device.

What causes high low side pressure and low high side pressure?

In this situation, where the high-pressure side of the AC is too low, and the low side pressure is too high, the problem is probably compressor-related. It could also be related to the AC pressure switch, the expansion valve, the evaporator, or the dryer. There could also be a leak in the AC system.

Can you reuse a line set?

As long as you properly remove all refrigerant and oil, it’s ok to reuse a line set that once held R-22 refrigerant.

How long do line sets last?

With the absence of contamination concerns, the general accepted life expectancy of line sets is 25 Yrs., outside of that number, you’re on borrowed time. Make yourself an expert, be street smart – know when to recommend new: 1.

How short can AC line set be?



The minimum that it can be cut down to is 10′. If cut down it must be re-flared. If you need longer than 25′ you may purchase a run up to 50′ from a HVAC parts house. Refrigerant lines cannot be spliced together it should be one continuous run.

What happens if piping is less than the minimum recommended length?

Answer. If an air conditioner is installed with shorter piping than the minimum required length, excessive noise or vibrations may be generated from the unit, and the system may not perform as designed.

How far can you run line set?

What are the Maximum and Minimum Length of a Single Line Set? 15 feet is the minimum, and 100 feet is the maximum. Those are complete line sets with flare nut fittings, ready to be installed. Rolls of lineset for professional use are available in lengths up to 164 feet.

How do you measure a line set?

Quote from the video:
Quote from Youtube video: This particular unit is a quarter-inch liquid line by 3/8 inch suction line by 25 feet you just need to calculate your length. And find the right line set for your installation.

How do AC line sets work?



A line set is simply a pair of copper tubes that connects a condenser to an evaporator. In the case of a mini-split system, the line set connects the indoor and outdoor units together, where the outdoor unit (condenser) supplies the indoor unit (evaporator) with refrigerant.

How do you calculate refrigerant for a line set?

per foot additional for the lineset, plus 6oz. for the filter drier, and the long radius elbows add 2.6 additional feet. 22.6 ft x 0.6 = 13.5oz + 6oz.