NEMA 10 isn’t included, because you are not supposed to design any new equipment using it! NEMA 10 was for 125V/250V ungrounded receptacles. Except allowed to combine ground with neutral in certain circumstances.

What does the number in NEMA mean?

The first number in a NEMA listing determines the voltage rating. A 5 represents a voltage rating of 125 VAC, while a 6 identifies a rating of 250 VAC. The rating given is the highest voltage allowed for use with the device by the standard.

What is a NEMA 10-30?





NEMA 10-30 is an nongrounded 120/240V device (hot, hot, neutral), NEMA 6-50 is a grounded 240V device (hot, hot, ground). A 10-30 receptacle will be protected by a 30 ampere breaker, and supplied by wires only rated to carry 30 amperes of current. If you plug a 50 ampere load, into a 30 ampere circuit.

What is a NEMA 10 50?

The NEMA 10-50 is an older style outlet that is rated for 50 amps and is commonly used for electric cooking ranges. Note: This adapter is intended for electric car charging and therefore does not have a neutral connection.

Is NEMA 10-30 grounded?

EV Charging Station Plug Warning: NEMA 10-30 has no Ground.

What does NEMA 12 mean?

NEMA 12 Enclosures constructed (without knockouts) for indoor use to provide a degree of protection against circulating dust or fibers, falling dirt and dripping non-corrosive liquids.

Can you plug a 20 amp plug into a 15 amp outlet?





It is not possible to fit 20-amp electrical plugs into 15-amp outlets. A 15-amp circuit is usually protected by a 15-amp circuit breaker. A 20-amp circuit is protected by a 20-amp breaker or fuse.

What is the difference between NEMA 10 30P and 10-30R?

Older homes and dryers still have the 3-prong NEMA 10-30 plugs and receptacles. These NEMA 10-30P plugs will only work with the 30 Amp 240 Volt NEMA 10-30R outlet, as you know. If you purchase a new dryer or new construction, post-1996, then you will likely run into the 4-prong NEMA 14-30 plugs and receptacles.

What is a 10-30R used for?

length. The NEMA 10-30 is an older style outlet that is rated for 30 amps and is commonly used for electric clothes dryers.

How do you wire a 10-30 plug?


Quote from Youtube video: The neutral wire you want to pay attention to it should be white and make sure you connect it to the l-shaped neutral pin on the new.

What is a NEMA 14 50 outlet?



A NEMA 14-50 outlet is for a plug-in Level 2 charger. In a hardwired installation, the conduit is run from the electrical panel directly into the charger. In a plug-in installation, the conduit is run from the subpanel to a NEMA 14 50 outlet.

What is a NEMA 14 30 plug?

The NEMA 14-30 adapter will allow a Tesla to draw up to 24 amps (5.7 kW at 240 volts). Recharge speeds will vary between different models.

What NEMA 13?

NEMA 13 enclosures are designed to protect electrical equipment from dust, sprayed water, oil and non-corrosive coolant in indoor environments. Dependable NEMA 13 boxes are available in plastic and aluminum in a variety of styles and sizes.

What is NEMA 6P?



A NEMA 6- or 6P-rated enclosure ranks among the most durable and watertight protection that an electronic device can have. The 6 and 6P ratings offer all of the same weatherproofing features of a 4 or 4X enclosure, but add protection against: Occasional temporary submersion (Type 6)

What does NEMA 7 mean?

NEMA 7 enclosures are designed to contain an internal explosion without causing an external hazard. These enclosures are intended for indoor use in hazardous locations classified as Class I, Division I, Groups A,B,C, or D.

What does NEMA 10 mean?

Quote from the video:
Quote from Youtube video: It has two terminals on an angle. And one that is shaped like a null nema 1030 is rated for up to 30 amps at 125. And 250 volts ungrounded it can step down to regular 125 volts with the use of 1030y.

What does NEMA 9 mean?

N/A. 9. HAZARDOUS. Intended for indoor or outdoor use in Class II, Groups E, F, and G environments. per NFPA rating system.

What is a NEMA 8 rating?



NEMA-RATED ENCLOSURES FOR HAZARDOUS LOCATIONS:



NEMA 8 enclosures are designed to prevent combustion in oil-immersed equipment, while NEMA 9 enclosures prevent the ignition of combustible dust. These particular enclosures are defined by the National Electric Code® (NEC) and National Fire Protection Association (NFPA).

What is NEMA 23?

NEMA 23 is a stepper motor with a 2.3×2.3 inch (58.4×58.5 mm) faceplate and 1.8° step angle (200 steps/revolution). Each phase draws 2.8 A at 3.2 V, allowing for a holding torque of 19 kg-cm. NEMA 23 Stepper motor is generally used in Printers, CNC machine, Linear actuators and hard drives.

What is a NEMA 4 rating?

The NEMA 4X definition, as established by the National Electrical Manufacturers Association, is a rating for an outdoor electrical enclosure that has the following protective qualities: Includes a gasket designed to protect against liquid and solid ingress. Suitable for indoor or outdoor use. Resistant to corrosion.