Does AP trap need to be lower than drain pipe?

It is not ideal to have the p-trap below the the exit drain because water gravity has to force the water out instead of it flowing downwards naturally. They both work and have seen it many times. But essentially anything below already creates its own p-trap- so using another is redundant.

Does the trap have to be directly under the drain?





Building codes do not mandate a minimum required vertical distance between the sink drain and the trap, but several factors dictate the minimum length of the tailpipe for a particular installation.

Why should there be an air gap between a sink drainpipe and the floor drain?

Air gaps prevent cross-connections and contamination by discharging water and waste across an unobstructed space (a gap of air). That space is between the fixture outlet and the “flood level rim” of a receptacle (be it a sink, floor drain, standpipe, or other approved unit).

What is the difference between an air gap and an air break?

An air break simply requires that there be no direct physical connection between the fixture indirect waste pipe and the receptor (see Figure 801.2a). The drainage air gap is not the same as the water distribution air gap. The water distribution air gap is defined in Chapter 6 and determined by Table 603.3.

Can you put AP trap in the wall?

Cleanouts absolutely have to be accessible. In fact, if they aren’t, you have to extend them to where they are accessible. But a lot of traps are sealed up in walls or floors/ceilings after inspection, particularly for things like washing machines, tubs and toilets.

How far can ap trap be from fixture?





What is the minimum and maximum distance a P-trap can be below a sink? There is no minimum distance specified by the building code, but the maximum is 24” per International Residential Code (IRC) and Residential Edition of Florida Building Code (FBC 1002.1), measured from fixture outlet to trap weir.

Why does a shower require a 2 inch drain?

A 2-inch pipe is the recommended size because showers have a low threshold for flooding, and a 2-inch pipe helps the water drain faster than does a 1 1/2-inch pipe. So, if you are converting from a tub and shower combination to a shower, you’ll likely have to change the drain pipe size.

Can a drain trap be too deep?

When the trap is too deep, liquid may flow through it too fast, which can lead to siphoning of the trap seal and sludge buildup. The drain connection at the wall is too high on this sink, resulting in a 9-inch-deep trap seal — 5 inches deeper than is allowed by code.

Do you have to put a trap on a shower drain?

Yes, shower and tub drains require a trap in the plumbing to prevent harmful sewer gases from coming into the home.

Is an air gap necessary?



Air gaps are the most effective means of preventing your drain from cross-contaminating your dishwasher with waste. If you want to protect your dishwasher from flooding with contaminated water, you need an air gap. Dishwasher air gaps are also required by plumbing codes in many locations.

What is an air gap drain?

Plumbing codes call for an air gap between portable water and a drain. This gap is usually about the distance between the faucet and the top of the sink or bathtub (one inch or more). Basically, the air gap is there to prevent accidental backflow. If contaminated water backflows, it can cause serious health risks.

What is the minimum air gap?

The minimum required air gap shall be twice the effective opening of a potable water outlet unless the outlet is a distance less than three times the effective opening away from a wall or similar vertical surface in which cases the minimum required air gap shall be three times the effective opening of the outlet.

What is the appropriate height of an air gap?



For effective openings not greater than one-half inch, a minimum airgap of one inch is required. Therefore, all airgaps must be at least one inch in vertical distance above the flood level rim.

What is indirect drain?

An indirect waste is a drainage piping that runs from a plumbing fixture or appliance and discharges into a separate waste pipe or receptacle. That waste piping connects to the building drainage system. The indirect waste line is not hard piped to the separate waste piping or receptacle.

Which space distance is acceptable for air gap?

Fixed Air Gap System

To achieve an acceptable air gap allow a space of two times the inside diameter of the water supply line. Example: For a 3-inch water supply line the minimum air gap which must be maintained would be 6 inches (2 X 3”).

Can air gap install under sink?



The majority of air gap installation occurs beneath the far edge of a sink basin’s rim. Air gaps create an outlet between waste water drain lines and appliances that discharge water, such as dishwashers and water filtration systems.

Does a garbage disposal need an air gap?

When there is a garbage disposal installed, the dishwasher drain line should run down from the air gap or high loop and connect to a side nipple on the disposal, where it connects with a hose clamp.

Do you need a high loop if you have an air gap?

GE: “If an air gap is not required, the drain hose must have the high loop from the floor to prevent backflow of water into the dishwasher or water siphoning out during operation.”

What happens if your dishwasher doesn’t have an air gap?

If your dishwasher doesn’t have an air gap, its drain hose may be looped up and attached to the bottom of the countertop near the sink. Although this is not code-compliant in most places, it serves the same purpose as the air gap—to prevent drain water from siphoning back into the dishwasher.