Can a GFCI be connected to a light switch?

Electrically there is no problem with powering the light with the hot and neutral feed to the GFCI receptacle. You could use pigtails to the receptacle line (and not use the load connection) and to the light switch so the lights would’t go out if the GFCI receptacle tripped.

Can a GFCI be wired to a switch?





SWITCH cable:



Delivers power from the GFCI to a switched load when wired to the GFCI. The switch cable can also be wired without GFCI protection.

How do you wire a GFCI light switch combo?

Wiring a Switched GFCI Combo Outlet



To do this, simply connect the upper wire (there are two builtin wires on the back side of GFCI) to the line terminal of GFCI while the second wire should be wired to the incoming line (phase, live or hot) wire.

Can lights be on a GFCI breaker?

Code requires one lighting outlet at each exterior door. If an outdoor light is in a damp location, it must be listed appropriately. Likewise, wet locations must use light fixtures approved for wet locations. Plug-in lighting must plug into an approved GFCI receptacle designed for the area.

Should bathroom lights be on GFCI?

As mentioned above, GFCI protection is required for any electrical outlets or switches that are in the area where you could get wet while using your bathroom. This includes the bathtub area, sink area, and shower stall.

How do you wire a GFCI to a bathroom?





Quote from the video:
Quote from Youtube video: And you want to feed those wires into the line terminals. On the back of that. So the first thing i do is always wire the ground so the ground wire goes into the green terminal then the neutral.

Can bathroom lights and outlets be on same circuit?

The outlet receptacles must be served by a 20-amp circuit. The same circuit can supply the entire bathroom (outlets plus lighting), provided there are no heaters (including vent fans with built-in heaters) and provided the circuit serves only a single bathroom and no other areas.

Should the light be on on a GFCI outlet?

To test the GFCI outlet first plug a lamp into the outlet. The lamp light should be ON, then, press the “TEST” button on the GFCI which will trip the outlet and break the circuit. The GFCI’s “RESET” button should pop out AND the light should go out. This indicates the GFCI outlet is functioning properly.

Do light switches need to be GFCI protected?

Notice, GFCI protection is only required for receptacles. Whereas AFCI protection, is required for all outlets in the mentioned areas. So while the light switch doesn’t have to be GFCI protected, it does have to be AFCI protected.

Do you need special light switches for bathroom?



The NEC requires that switches not be installed within the confines of shower and tub areas, unless as part of a shower assembly. In other words, unless the switch is already built in to your shower assembly from the manufacturer, adding a switch inside a shower is a code violation.

Can you put a switch inside a bathroom?

For light switches, plate switches can be used on the inside of the bathroom, but these must be suitable for use in the bathroom, given the high levels of humidity and condensation. And they also must be at least 0.6m away from the bath or shower. A pull cord can be used instead, in any location in the bathroom.

Where should a light switch be placed in a bathroom?

It is best to locate the bathroom light switch just inside the entry door to the bathroom.

What is the electrical code for bathrooms?



The NEC requires that all outlet receptacles in a bathroom be GFCI protected. Outlet circuit must be 20 amps: The outlets in a bathroom should be served by a 20-amp circuit, separate from the lighting circuit, to provide power items such as curling irons, razors, and hairdryers.

How close can a light switch be to a bathroom sink?

3 feet

Every bathroom needs at least one electrical outlet. It must be within 3 feet of the sink edge. Across from the sink on an opposite wall is not acceptable, either behind or beside the sink. There must be an electrical receptacle within 3 feet of the two sinks in the bathroom.

Can I use 15 amp GFCI in bathroom?

Do you? Kitchens and bathrooms should always have 20 amp gfci outlets. However, you must be using number 12 wire for 20 amp gfci or regular outlets If your wiring is number 14 guage then use a 15 amp. So, the wire size and breaker size together should be rated for 20 amps!