Can you have a switched GFCI outlet?

No. GFCIs receptacles cannot be switched, nor can they be split. Best bet is to use a GFCI breaker in the panel, then you can use regular receptacles that you can split and switch, and everything will be protected.

How do you wire an outdoor GFCI outlet?





Quote from the video:
Quote from Youtube video: Take a length of romex cable and feed it through the hole in the electrical. Box from the inside. Run it through the wall. And out through the cutout. Section you created on the exterior of the house.

How do you wire a GFCI outlet with a switch?

How do I wire a switch to control a GFCI Receptacle?

  1. Place the switch in the hot wire going to the “line” side of the GFCI outlet.
  2. Run the neutral wire uninterrupted to the “line” side of the GFCI outlet.
  3. Connect ground wires as usual, switch and outlet.


Can GFCI outlets be used outside?

Outdoor electrical outlets differ from indoor outlets because they have watertight covers that protect the outlet even with a cord plugged in. Plus, the National Electrical Code requires all outdoor outlets to be GFCI outlets (ground fault circuit interrupter outlets).

Is there a difference between GFI and GFCI?





Ground fault circuit interrupters (GFCI) and ground fault interrupters (GFI) are the exact same device under slightly different names. Though GFCI is more commonly used than GFI, the terms are interchangeable.

How do you wire a GFCI outlet with 3 wires?

Quote from the video:
Quote from Youtube video: That's going to be connected to the screw terminal for the neutral side so the neutral side is going to go to the silver screw.

What is code for outside outlets?

Homes must have at least one outdoor receptacle at the front and rear of the house. They must be readily accessible from the ground and positioned no more than 6 1/2 feet above grade (ground level).

Does an outdoor outlet have to be on its own circuit?

You can come off any non dedicated space circuits. Some companies come off one of the garage circuits. But if you’re doing large houses. That wouldn’t be prudent.

Do outdoor outlets need arc fault protection?



AFCI protection is not required for outlets located outside or in garages or bathroom areas.

Can you put a GFCI receptacle on an arc fault breaker?

It’s perfectly fine to connect a circuit that is GFCI on an arc fault breaker, so don’t worry about damaging the breaker if you decide to do this.

What is the difference between a GFCI and AFCI?

The GFCI simply makes a continuous comparison of the amount of current flowing through the two circuit conductors, while the AFCI continuously monitors the current waveform in the circuit, looking for unique anomalies that signify an arc fault.

Do I need both GFCI and AFCI?



In 2014, the National Electrical CodeĀ® (NECĀ®) introduced AFCI requirements for kitchens and laundry rooms. The code had previously required that these locations needed only GFCI protection, but for added safety they are now required to have both AFCI and GFCI protection.

Where are AFCI breakers required 2020?

AFCI current requirements in the NEC 2020 code:



Common rooms. Hallways and closets. Kitchens. Laundry areas.

Where is AFCI required?

As of the 2014 NEC, AFCI protection is required on all branch circuits supplying outlets or devices installed in dwelling unit kitchens, along with the 2008 NEC additions of family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, and …

Where should AFCI be installed?

AFCI outlets are recommended for the following locations in a house: family rooms, dining rooms, dens, bedrooms, closets, hallways, recreation rooms, sunrooms.

Can I put an AFCI anywhere into the circuit?



AFCIs (Arc Fault Circuit Interrupters) can be used anywhere but the Bathroom and Kitchen.

Does refrigerator need AFCI?

Refrigerator Circuit



This circuit usually does not require GFCI protection unless the outlet is within 6 feet of a sink or located in a garage or basement, but it generally does require AFCI protection.