How much clearance do you need for a wood burning stove?

36-inch





All stoves require a minimum 36-inch clearance to unprotected combustibles above and on all sides of the stove. A single wall stovepipe must have a clearance to combustible walls and ceilings, measured at right angles to the pipe of at least 18 inches. No clearance is needed to noncombustible walls (i.e., concrete).

How much space do you need around a chimney?

Chimneys located entirely outside the exterior walls of the building, including chimneys that pass through the soffit or cornice, shall have a minimum air space clearance of 1 inch (25.4 mm). The air space shall not be filled, except to provide fire blocking in accordance with Section R1001.

How much clearance does a flue need?

The flue must be at least 1.5 times its external diameter away from the heat shield, the heat shield must extend at least 1.5 times the flue’s external diameter to each side of the flue, and there then has to be an air gap of at least 12 mm between the shielding material and the combustible material.

How close to wall can wood stove be with heat shield?

Do I need a heat shield for my stove? The Fire Protection Association recommends that the common radiant-type stove must be spaced out by 900mm (36 inches) from a combustible wall. Using a heat shield can reduce the space required to 95mm as stated by HETAS.

How close can you put a wood stove to a non combustible wall?





36 inches

Wood frame walls covered with dry wall are considered combustible. If no wall protection is used, the common radiant-type stove or heater must be spaced out at least 36 inches from the wall. This distance may be reduced considerably if asbestos millboard and/or 28 gage sheet metal is used for wall protection.

Can I complain about my Neighbours wood burning stove?

In cases where our evidence shows that smoke or fumes is causing significant interference with another person’s use and enjoyment of their property we can serve a legal notice on the person(s) responsible for the nuisance, requiring action to be taken to stop the problem or face prosecution for non compliance.

What should be the distance between stove and chimney?

The minimum distance between your gas cooktop and your range hood must be 65 centimeters.

What is code for wood around fireplace?



The National Fire Code dictates that any combustible material (e.g., wood mantel or similar trim) must be at least six inches from the firebox opening. An additional inch of clearance is needed for every 1/8 inch the combustible material or trim protrudes.

How high should a wood stove chimney be above the roof?

3 feet

The 3-2-10 Rule. The chimney opening above the roof of a sticks and bricks house should be 3 feet above the roof line, or 2 feet above any part of the building within 10′, whichever is higher.

Can I use cement board as a heat shield?



Hardi cement board is an inexpensive solution that will form the foundation of an effective heat shield for any application. Hardi cement board is also designed to have ceramic, porcelain or stone tiles installed over it to cover and beautify the heat shield after it is installed.

How do I fireproof a wall behind a wood stove?

A common way to help protect the wall behind a wood stove and create a backdrop for your stove includes using masonry veneer faux panels. Stone or brick is a common material to use behind a wood burning stove. These panels help create more of a focal point for a room.

Do I need a heat shield behind a wood stove?

Wood stoves require heat shields both under and behind them to protect your home from heat damage. While many wood stoves include heat shields in their design, some do not. Refer to your wood stove to determine if external heat shields are necessary.

How far should stove be from wall?

There should be two inches of space between the back wall and a drop-in or slide-in (gas or electric) style range. A freestanding range (gas or electric) requires no space between it and the back wall. There should be at least twelve inches between any style range and the closest sidewall.

How much wall space do you need for a fireplace?



You should make sure your fireplace location is at least 36 inches from a wall that lacks protection. You can reduce the clearance to 12 inches if you add a wall protector. The front and side of the unit should have a non-combustible extension.

How wide is a standard chimney?

Prefab or metal chimneys, class A and double or triple walls are usually found in three diameters.
Prefab or Metal Chimneys.

Chimney Size Common Venting Uses
Inside diameter (inches) Inside Area (square inches)
6 28.3 Stoves, Central Heaters
7 38.5 Stoves, Central Heaters
8 50.3 Stoves, Small Fireplaces, Central Heaters

What is the standard size of a chimney?

Most chimneys are available in two standard sizes—60 cm and 90 cm. If you have two-burner stove, you can go for a 60 cm-wide chimney. If your stove has three burners or more, opt for a 90 cm-wide chimney.

How wide does a chimney need to be?

As a general rule, the diameter of the chimney should match the flue collar on your wood stove. A 6-inch stove requires a 6-inch flue. In most cases, a step up is also fine. For example, you could vent a 6-inch stove into an insulated chimney that is 8 inches in diameter.

Is 4 inch pipe enough for chimney?



It is suitable only if your chimney exhaust size is 4 inches. Similar type Flexible Duct offers a flexible 4-inch pipe specially designed for kitchen chimneys. Its pipe size is Diameter is 4.3 Inches, Length 3.3 Feet and Expanded Up To 10 Feet (L x B x H).

What size chimney do I need for a wood stove?

In general, flue size should be 25 percent larger than the size of the stove pipe, which connects the stove to the chimney. This means a stove with a 6-inch diameter pipe would require at least an 8-inch flue; an 8-inch stove pipe requires a 10-inch flue, etc.

Does a chimney need to be lined for a wood burning stove?

A chimney liner is obligatory if you are installing a woodburning stove, gas fire or open fire in a new build property to comply with Document J of current Building Regulations. A chimney liner may be necessary in an older property if the flue inside your chimney is no longer safe to use.

Can I install a chimney liner yourself?

Yes it can – and will! While having your chimney liner professionally installed can be more convenient but ends up being costly, averaging anywhere from $2,500 to $5,000. With our DIY Chimney Liner Kits you will have all the components needed to reline your chimney and you wont break the bank!

Do I need a stainless steel liner for my chimney?

Do Chimney Liners Need to Be Insulated? Stainless steel chimney liners are very effective in absorbing heat. As a result, it is recommended that metal liners be insulated to protect the masonry further. Insulating stainless steel liners will increase safety and performance.