You need a 3-3-3-5 copper SER cable to carry 100 amps (that’s three #3 gauge for the two hot wires and the neutral and a #5 gauge for the ground). If you want to use aluminum, you need at least #2 gauge or perhaps #1.

What size wire do I need to supply a 100 amp subpanel?

#4





The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example. (Aluminum is often used for feeder cables because the cost is typically much lower than that of copper wires.)

What size wire do I need to run a 100 amp service 200 feet?

To feed a 100 ampere secondary panel 200 ft. from the main panel, you’ll want to use 1 AWG copper or 2/0 aluminum conductors. This is large enough to safely carry 100 amperes, and to maintain power quality over the distance.

What size wire do I need for a 100 amp underground 300 ft run?

for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit, …

What size wire is good for 100 amps?

A 100 amp sub panel wiring size requirement is #4 for copper wires and #2 for aluminum wires.

What size wire do I need for 100 amp service 100 feet away?





If you check the wire size chart (you have the link in the introduction), the #0 AWG wire (also known as 1/0 AWG wire) has 150 ampacity. That means that #0 AWG wire is the perfect size wire for 100 amp service 100 feet away.

What size wire do I need to run 100 amp Service 150 feet?

What is the right wire size for 100 Amp service 150 feet distance? You should get 2/0 AWG Copper wire or 4/0 AWG Aluminum wire for single-phase circuits. And, 1/0 AWG Copper wire or 3/0 AWG Aluminum wire if you have three-phase circuits. For these wires, the average voltage drop should be 3%.

Can you run a 100 amp sub panel off a 100 amp sub panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

Can I run a 100 amp sub panel off 200 amp main?

Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance, …

What size breaker do I need for a 100 amp service?



20/24 panels can hold 16 full-sized and 4 twin breakers (24 circuits in total). The number of breakers can max out to 30-42, too, depending on the design of your 100-amp pane. However, NEC prohibits more than 42 circuits, so you can only choose between 20-42 breakers for a 100-amp panel.

Can you feed a 100 amp sub panel with a 50 amp breaker?

Just wire it up. There is no problem using a sub panel that can take more current than you will ever feed it. Points to note: The cable to your hot tub will be rated for 50A (not 100A); therefore you must not upgrade the breaker in your main panel to 100A.

How much load can a 100 amp panel handle?

In other words, a 100-amp electrical service should be expected to provide no more than 19,200 watts of power load at any given time.