What building code is used in North Carolina?

The NC State Building Code is adopted and amended by the NC Building Code Council for implementation across the state.

How deep should footings be in NC?





Footing must be dug down into undisturbed soil and to a minimum depth of 12-in below the finished grade.

What is code for exterior wall studs?

The size, height and spacing of studs shall be in accordance with Table 23-I-R-3 except that Utility grade studs shall not be spaced more than 16 inches (406 mm) on center, or support more than a roof and a ceiling, or exceed 8 feet (2438 mm) in height for exterior walls and load-bearing walls or 10 feet (3048 mm) for …

Does a bathroom need a window in NC?

Bathroom Ventilation – Bathrooms shall be provided with windows of not less than 3 square feet of which one-half must be operable.

What counts as a bedroom in NC?

Under the North Carolina Residential Building Code if a room has at least 100 square feet and at least 50 of the room has a ceiling height of greater than 7 it can be called a bedroom. The NCRBC also requires a bedroom to have a window or door leading directly to the outside for access in case of an emergency.

Does a bathroom need an exhaust fan?





If you’re not using your exhaust fan every time you shower, you should, or if it’s broken you need to get it fixed ASAP. The exhaust fan in your bathroom is responsible for removing excess moisture, odors, and stale air. Without it, bacteria and mold will thrive.

What is the electrical code for bathrooms?

The NEC requires that all outlet receptacles in a bathroom be GFCI protected. Outlet circuit must be 20 amps: The outlets in a bathroom should be served by a 20-amp circuit, separate from the lighting circuit, to provide power items such as curling irons, razors, and hairdryers.

Does a bathroom need a window?

The primary reason your bathroom needs at least one window is to effectively remove moisture from the air. Without a window or some type of ventilation system, this moisture can spur mildew and mold growth, which can jeopardize the health of your family.

What is the code for bathroom ventilation?

The model building codes adopted by most jurisdictions typically require bathroom ventilation to be provided either by an operable window (3 sq. ft. or greater) or by mechanical means – a bathroom vent fan (20 continuous or 50 cfm intermittent, vented to the building exterior.

Does a toilet room need a vent?



Bathroom Ventilation Requirements

Full bathrooms must have ventilation that sends the air outside, such as an Energy Star certified exhaust fan that creates airflow of 50 cubic feet per minute (cfm). Alternatively, homeowners can use a window with the ability to open to at least 4% of the square area of the bathroom.

Does a bathroom exhaust fan need to be on a GFCI?

Although the National Electrical Code (NEC) does not have a requirement for a bathroom exhaust fan to be GFCI protected, it is often specified by the manufacturer in the installation instructions when the fan is over a tub or shower.