Why does my electric motor keep tripping the breaker?

A circuit breaker will trip if a power surge exceeds its capacity. A circuit breaker will trip when the total current draw exceeds the breaker’s capacity. The current surge when a motor starts can trip the breaker. Shorts, ground faults, rusty connections and extension cords can also cause breakers to trip.

What size breaker do I need for a 5 hp motor?





A 5hp single phase AC motor has a load current of 28 Amps. So 10GA. wire with a 30 Amp breaker will work.

What size breaker do I need for a 15 amp motor?

A 12 wire and a 20A breaker is needed. 15A ends can be used on 20A circuits.

How do you measure a breaker for a 3 phase motor?

Breaker size must be rated for a minimum of 125% of the full-load current of the motor it is protecting, rounded up to the next standard breaker size. For example, the full-load current of a 5 HP motor at 460V is 7.6 Amps. The breaker must be sized for 7.6 * 1.25 = 10 Amps .

What can cause a motor to overload?

Electrical overload or over-current is caused by an excessive current flow within the motor windings, exceeding the design current which the motor is able to carry efficiently and safely. This can be caused by a low supply voltage, resulting in the motor drawing in more current in an attempt to maintain its torque.

How do you check motor overload?





Overload Protection Test:

  1. Measure the normal motor running current (i motor).
  2. Turn off the motor and let it cool for about 10 minutes.
  3. Calculate the following ratio: i (motor) / i (overload min FLA). …
  4. Set the overload to its minimum FLA and turn on the motor.
  5. Wait for the overload to trip.

What size breaker do I need for a 20 amp motor?

Full Load Current: Three Phase AC Motors

Motor Horsepower Size Breaker
10 230V 460V 50 30
15 230V 460V 70 40
20 230V 460V 100 50
25 230V 460V 100 50

How many amps does a 7.5 hp motor draw?

AC Motor Full Load Amperes

HP 200 Volts 380-415 Volts
5 17.5 9.7
7.5 25.3 14
10 32.2 18
15 48.3 27

How many amps does a 5.5 hp motor draw?



AMP DRAW BASED ON HORSEPOWER

HP 1 Phase Amps 3 Phase Amps
115 volt 230 volt
3 34 9.6
5 56 15.2
7-1/2 80 22

How do you size a circuit breaker for a motor?

You must size the overloads no more than 115% to 125% of the motor nameplate current rating, depending on the conditions [430.32(A)(1)]. You must size the short-circuit ground-fault protection device from 150% to 300% of the motor FLC [Table 430.52].

How many amps does a 3 phase motor draw?

Here are the Full Load Amp (FLA) values for typical 230VAC and 480VAC 3 phase motors.

Motor horsepower Full load amps 230VAC Full load amps 460VAC
3 9 4.5
5 15 7.5
7.5 22 11
10 27 14

What is full load current of a 3 phase motor?



For three-phase, full load current for the resistive load is equal to the three-phase power divided by 1.732 times of voltage. Here power factor will be unity for resistive loads. Full load current I, I =P.

How do you protect an electric motor from overload current?

Overload relays protect the motor, motor branch circuit, and motor branch circuit components from excessive heat from the overload condition. Overload relays are part of the motor starter (assembly of contactor plus overload relay). They protect the motor by monitoring the current flowing in the circuit.

What is the maximum overload setting of a motor?

The maximum allowable size for the overloads is 9.8A. The overloads can be sized at 140% of the FLA if the overloads trip at rated load or will not allow the motor to start, 7A x 1.4 = 9.8A.

What is overload on a motor?

Motor overload occurs when a motor is under excessive load. The primary symptoms that accompany a motor overload are excessive current draw, insufficient torque and overheating. Excessive motor heat is a major cause of motor failure.

Which device will protect a motor from an overload or overcurrent condition?



An automatic device that is designed to safely disconnect circuits under fault conditions. Most circuit breakers provide Overload and Overcurrent protection, and are rated in Volts, Amps and Horsepower.

What is the difference between overload and over current?

Short circuit is a type of overcurrent. Magnetic circuit breakers, fuses and overcurrent relays are commonly used to provide overcurrent protection. Overload protection is a protection against a running overcurrent that would cause overheating of the protected equipment. Hence, an overload is also type of overcurrent.

Do all motors need overload protection?

Most other continuous duty motors having a marked service factor of not less than 1.15 or, with a marked temperature rise not over 40 degrees Celsius, are required to have overload protection rated at 125 percent of the motor nameplate full-load current rating.

What are three warning signs of an overloaded electrical circuit?

Signs of Overloaded Circuits

  • Dimming lights, especially if lights dim when you turn on appliances or more lights.
  • Buzzing outlets or switches.
  • Outlet or switch covers that are warm to the touch.
  • Burning odors from outlets or switches.
  • Scorched plugs or outlets.