It can be counted as a required receptacle since it does meet the letter of the code. Show activity on this post. (1) Spacing. Receptacles shall be installed such that no point measured horizontally along the floor line of any wall space is more than 1.8 m (6 ft) from a receptacle outlet.

What must be installed wherever outlets are required according to the NEC what article of NEC is talking about this requirement?

According to 210.52(A)(1), a receptacle outlet must be installed so that no point along the floor line of any wall is more than 6 ft, measured horizontally along the floor line, from a receptacle outlet, as shown in the Figure.

How is the minimum number of receptacle outlets determined for the living room What article of NEC is talking about this?





One location not mentioned is closets. Although receptacle outlets within closets are permitted, they are not required. The amount of wall space determines the minimum number of receptacle outlets in a given dwelling. Wall space is measured horizontally along the floor line.

Why is there a maximum number of outlets or number of outlets allowed for branch circuit protection?

Because of the higher rating on a 20-ampere breaker, more receptacles are permitted than on 15-ampere overcurrent devices. The calculated load per receptacle is the same, 1.5 amperes.

How many receptacle outlets are provided in the kitchen?

As mentioned in June, a minimum of two small-appliance branch circuits are required in kitchens. [210.52(B)(1)] Kitchen countertop surfaces have the same requirement. At least two small-appliance branch circuits are required to feed the receptacles that serve countertop surfaces in a kitchen.

What are the types of rules contained in the NEC?

There are two basic types of rules int the NEC; what are they? Mandatory rules and permissive rules. Actions that are allowed but not required and typically cover options or alternative methods.

Which of the following receptacle locations does not have to be GFCI protected?





GFCI protection is not required for receptacles serving appliances like dishwashers, or convenience receptacles that do not supply countertop surfaces. Receptacles installed within 6 ft of the outside edge of a wet bar sink must also be GFCI-protected [210.8(A)(7)].

What is the NEC code for outlets?

The US National Electrical Code, Section 210.52, states that there should be an electrical outlet in every kitchen, bedroom, living room, family room, and any other room that has dedicated living space. They must be positioned at least every twelve feet measured along the floor line.

What type of receptacles are required in the kitchen?

Requirement: Provide at least two 20-amp, 120-volt circuits to supply power to GFCI (Ground Fault Circuit Interrupter) receptacles for countertop and eating areas.

What outlets are required in a kitchen?

The National Electrical Code (NEC) requires that kitchens have at least two separate 20-amp, 120-volt circuits for counter-top outlets, which must also be no more than 4 feet apart.

Are kitchen islands required to have a receptacle installed?



In the 2017 National Electrical Code (NEC), only one receptacle outlet is required to be installed for each uninterrupted, basic island countertop space that has a long dimension of 24 inches or greater, and a short dimension of 12 inches or greater. That’s it, a minimum of one receptacle outlet.

How many receptacles are required on a kitchen island?

Within the same section of the 2020 NEC, it has been revised to require at least one receptacle within the first nine square feet or fraction thereof, of an island countertop and an additional receptacle for every 18 square feet more or fraction thereof.

Does a kitchen peninsula need an outlet?

At least one receptacle outlet shall be installed at each peninsular countertop long dimension space with a long dimension of 600 mm (24 in.) or greater and a short dimension of 300 mm (12 in.) or greater. A peninsular countertop is measured from the connected perpendicular wall.

Where do outlets go on Peninsula?



(b) At least one receptacle outlet shall be located within 600 mm (2 ft) of the outer end of a peninsular countertop or work surface. Additional required receptacle outlets shall be permitted to be located as determined by the installer, designer, or building owner.

Do kitchen islands need GFCI outlets?

GFCI protection is required for all 15A and 20A, 125V receptacles that supply kitchen countertop surfaces [210.8(A)(6)].

Where are tamper resistant receptacles required by the NEC?

Tamper-resistant receptacles are also now required in hotel rooms, child care facilities, preschools, elementary education facilities, waiting areas in medical and dental clinics, dormitories, and waiting areas in any place of assembly, anywhere children may not be closely supervised.

Where are tamper resistant outlets not?

Exception: Receptacles in the following locations aren’t required to be tamper-resistant: Receptacles located more than 5½ ft above the floor. Receptacles that are part of a luminaire or appliance.

Are tamper resistant receptacles required?



Tamper-resistant (TR) receptacles were first required within the 2008 edition of the National Electrical Code (NEC).