The size of a sub panel for a workshop should be a minimum of 60 amps up to 100 amp power feed from your house or main service. This is assuming that you have at least a 200 amp main service. It should be 120/240 volt single phase.

Can I run a 100 amp sub panel off 200 amp main?

Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance, …

What size breaker do I need for a subpanel?





Based on your question, since you will be having a subpanel, you want the breaker feeding the subpanel to be sized for the subpanel or slightly smaller. So if you purchase and install a 200A subpanel, then the breaker should be 200A. If you use a 125A subpanel, then use a 125A breaker.

Can I run a 100 amp subpanel from a 100 amp panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

Can you run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

Can you feed a 100-amp sub panel with a 50 amp breaker?

Just wire it up. There is no problem using a sub panel that can take more current than you will ever feed it. Points to note: The cable to your hot tub will be rated for 50A (not 100A); therefore you must not upgrade the breaker in your main panel to 100A.

How many subpanels can you have on a 200 amp service?





Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.

Can you feed a 100 amp sub panel with a 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

How many breakers can I put in a 30 amp subpanel?

The amount of current that is required for the connected loads can only be supported by a 30 Amp sub-panel. The maximum quantity of branch circuits can be determined with a load calculation. Two 15amp breakers or one 15amp and one 20amp can be used on a 30amp circuit.

How many breakers can I run off a 60 amp sub panel?

Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

What size wire do I need to run a 200 amp sub panel?



The 250 KCMIL wire is the perfect size wire for 200 amp service because it has 255A ampacity (a minimum of 250A ampacity requirement is satisfied).

How do I know if my electrical panel is overloaded?

Buzzing or Sparking If you hear a buzzing sound or see sparks near the service panel, this indicates a major electrical problem. Overloaded circuits can damage breakers, connections and wiring, leading to arcing that creates sparks or buzzing noises, as well as a very serious risk of fire.

Can I add 100 amp subpanel?

If you have older 60-amp or 100-amp main service, it is entirely possible that you will need a service upgrade to 150-amps or 200-amps before you are able to adequately power a new subpanel.

How much load can a 100-amp panel handle?



In other words, a 100-amp electrical service should be expected to provide no more than 19,200 watts of power load at any given time.

Does a subpanel need a main breaker?

According to most experts, the subpanel doesn’t need a main breaker as the main panel already has a feeder breaker. But, to stop power during a short circuit, it’s possible to add a main breaker in the subpanel.

How many breakers can you put in a 100-amp panel?

20 circuits

Typical 100-amp panels have 20 circuits, meaning they can handle 20 full-sized breakers. 20/24 panels can hold 16 full-sized and 4 twin breakers (24 circuits in total). The number of breakers can max out to 30-42, too, depending on the design of your 100-amp pane.

What is the 6 breaker rule?



The “rule of six” refers to how many breakers or throws it takes to disconnect a building from the electrical supply, so if you have more than six breakers in a box at your service entrance there needs to be a disconnect upstream of it, either in the panel or upstream.

Can breakers add up to more than Main?

It is very common for the sum of the branch circuit breakers to add up to more than the main circuit breaker. The engineer that originally designed the building and electrical system understood that the loads were intermittent, and very unlikely to be maxed out at the same time.

Is 100 amp service enough for a house?

Most homes require an electrical service of at least 100 amps. This is also the minimum panel amperage required by the National Electrical Code (NEC). A 100-amp service panel will typically provide enough power for a medium-sized home that includes several 240-volt appliances and central air-conditioning.

How many amps does a 3 bedroom house need?

80-100 Amps



In a modern 3-4 bedroom home, the average demand works out around 80-100 Amps.

Do I need 100 or 200 amp service?

In general, homes under 3,000 square feet can use a 100 AMP panel as long as they don’t use air conditioning or electric heat. Homes over 3,000 square feet and homes that rely on electric heat and air conditioning will typically be better served by a 200 AMP panel.