If a GFCI outlet or circuit breaker is tripping, it is typically because the Neutral connection on the switch is tied to Ground. This is a safety hazard and violation of National Electrical Code. If you are unsure please contact an electrician.

Why does my bathroom light keep tripping the breaker?

Here’s what to do if your lighting keeps tripping your circuit breakers: Circuit breakers can trip due to any number of problems. That can include water damage, frayed wiring, worn fittings, bad connections, faulty transformers or simply an electrical load that is more than the system can handle.

Do bathroom lights have to be GFCI protected?





You might not be aware of it, but your bathroom lights could pose a safety hazard in the event that you have an electrical short. This is because GFCI (ground fault circuit interruption) protection is only required for outlets and switches, not light fixtures unless they are above the shower area.

Can LED lights cause GFCI to trip?

Electrical Problem with an LED Light Tripping a GFCI Outlet



The GFCI Outlet must be wired from the wiring of the same circuit, therefore the wiring must be contiguous, and not connected to other circuit wires because this could cause the GFI Outlet to trip, but there is more to this problem as described below.

Can a light be on a GFCI circuit?

Electrically there is no problem with powering the light with the hot and neutral feed to the GFCI receptacle. You could use pigtails to the receptacle line (and not use the load connection) and to the light switch so the lights would’t go out if the GFCI receptacle tripped.

Can bathroom lights and GFCI be on same circuit?


Quote from Youtube video: And the receptacles are on the exact. Same circuit. So if you do trip one of these gfci receptacles the lights are going to go out so you're not going to have lights in here if you do manage to trip

Can the outlets in a bathroom be on the same circuit as the lights?





No lighting outlets or other equipment can be fed from the same circuit feeding the bathroom receptacles. For example, a one-family dwelling has two bathrooms and a duplex receptacle has been installed in each. One 20-ampere branch circuit can supply power to both bathroom receptacles but cannot feed anything else.

Do bathroom lights need dedicated circuit?

The bathroom electrical code now stipulates that the bathroom must have dedicated circuits that aren’t shared with outlets or lights in any other room. You must provide at least two of these circuits. One is a 20-amp circuit that powers the outlets, and the other is a 15-amp circuit for the lights.

Can lights be on an outlet circuit?

Yes, you can. The average home uses an indoor distribution board that houses the breakers of the majority of circuits in the home. A circuit controlled by a 15A circuit breaker (which a lot of contractors use for general lighting) can also accommodate outlets.

How close can a light switch be to a bathroom sink?

National Electrical Code says that the receptacle must be within 3′ of the outside edge of the basin, but not more than 12″ below the top of the basin (210.52(D)).

How close can a GFCI be to a bathroom sink?



Every bathroom must have at least one electrical outlet. It must be a GFCI, and it must be within 3 feet of the edge of the sink. Either behind or beside the sink is acceptable — across from the sink on an opposite wall is not. If the bathroom has two sinks, each must have an electrical receptacle within 3 feet.

How far does a light switch have to be from a water source?

According to the National Electric Code (NEC), GFCIs are required to be installed to protect any receptacles within 6 feet of a water source.

How far from a sink must a light switch be?

(SOURCE: DCLG; Fire Statistics, Great Britain April 2013-March 2014). Electrical sockets or switches should be fitted at a safe distance (it is recommended at least 30cm horizontally) from a sink to avoid the chance of water coming into contact with electricity.

How far from a sink DO YOU NEED A GFCI?



six feet

Kitchens – All receptacles located near major appliances and the sink should be of the GFCI variety. As a rule of thumb, any outlet within six feet of the sink should be a GFCI outlet.

How close can an electrical outlet be to a bathroom sink?

Outlet Receptacles



When considering bathroom receptacles, keep correct placement in mind. You should keep the receptacle at least 6 feet away from the edge of a bathtub or shower and at least 1 foot away from sinks.