Can bathroom lights and outlets be on same circuit?

The main rule in 210.11(C)(3) states that the branch circuit provided to supply the bathroom receptacle outlet(s) shall have no other outlets. No lighting outlets or other equipment can be fed from the same circuit feeding the bathroom receptacles.

Are switches allowed in bathrooms?





6 Answers from MyBuilder Electricians



Light switches are not allowed in bathrooms it has to be a pull cord or a switch outside. Radiator pipes do not have to be bonded IF boiler is cross bonded and/or you have rcd protection on the fuseboard.

How do you install a switch and GFCI outlet combo?

Wiring a Switched GFCI Combo Outlet



To do this, simply connect the upper wire (there are two builtin wires on the back side of GFCI) to the line terminal of GFCI while the second wire should be wired to the incoming line (phase, live or hot) wire.

Can you turn a switch into a switch and an outlet?

Yes, a switch can be converted into an outlet if the wiring can be identified back at the source and one of the wires (the neutral or white) can be connected to the neutral source.

Does a bathroom outlet need to be on its own circuit?

A The main rule of Section 210-11(c)(3) requires a 20A circuit that is dedicated to bathroom receptacle outlets. It does not require a separate circuit for each bathroom. One circuit may supply multiple bathrooms as long as only bathroom receptacles are supplied.

What is code for bathroom outlets?





The NEC requires that all outlet receptacles in a bathroom be GFCI protected. Outlet circuit must be 20 amps: The outlets in a bathroom should be served by a 20-amp circuit, separate from the lighting circuit, to provide power items such as curling irons, razors, and hairdryers.

Why switches are not allowed to install in bathroom?

Light switches are only permitted outside the bathroom and not in the bathroom, as someone in the bathroom with moist or wet hands can be exposed to the risk of an electric shock. Only pull cord switches are allowed in the bathroom. The bathroom circuits must also be RCD protected.

How close can a switch be to a bathroom sink?

National Electrical Code says that the receptacle must be within 3′ of the outside edge of the basin, but not more than 12″ below the top of the basin (210.52(D)).

Why are bathroom light switches outside the bathroom?

There’s a good answer: It’s to protect you. Electricity and water don’t mix. If a light switch is functional, it’s connected to a live wire. In new buildings with professional electrical installation, there’s a pretty low chance a light switch would shock you.

How do I wire a switch and outlet combo?



Quote from the video:
Quote from Youtube video: The two white wires from the power and the light fixture wire tie them together and I've also added a pigtail wire. Again a white wire with a loop at the end of it.

Can I add an outlet from a Light Switch?

Adding an electrical outlet next to an existing light switch is easy, as long as there is a neutral wire in the box. Step 1: Turn the power supply off to the light switch at the main electrical panel. Step 2: Remove the switch plate and unscrew the switch from the outlet box. Step 3: Pull the switch out from the box.

How do you wire a Light Switch and outlet in the same box?

Quote from the video:
Quote from Youtube video: Put those together. Then i'm going to take my two ground wire pigtails. And combine. Those with my two ground wires coming out of the box.

How do you wire a dual outlet diagram?



Quote from the video:
Quote from Youtube video: One of each wire for both receptacles. So you're going to need. Two ground pigtails you're going to need two neutral or white pigtails and you're going to need two black pigtails.

How do you wire a circuit with lights and outlets?

Quote from the video:
Quote from Youtube video: Process and i'm going to show you how to roll each set of wires back into the box including the grounds the neutrals. And the hots as well as how to do any pigtails that may be. Needed at the switch.

Can a GFCI outlet be connected to a light switch?

Electrically there is no problem with powering the light with the hot and neutral feed to the GFCI receptacle. You could use pigtails to the receptacle line (and not use the load connection) and to the light switch so the lights would’t go out if the GFCI receptacle tripped.

Do bathroom switches need to be GFCI protected?

As mentioned above, GFCI protection is required for any electrical outlets or switches that are in the area where you could get wet while using your bathroom. This includes the bathtub area, sink area, and shower stall.

Do GFCI outlets require special wiring?



You can replace almost any electrical outlet with a GFCI outlet. Correctly wired GFCIs will also protect other outlets on the same circuit. While it’s common to find GFCI outlets in bathrooms and kitchens, there are GFCI outlet requirements.

Does a shower light need to be GFCI protected?

A. Master electrician Sean Kenney responds: The short answer is yes. Although the NEC does not require either the switch or the light fixture to be GFCI-protected, most lighting fixtures designed for use in a shower stall require GFCI protection to meet UL requirements.

Can LED lights be used in showers?

LED lights have drastically increased the lighting options available for wet environments like bathrooms and showers.

How many GFCI do I need in my bathroom?

one GFCI



Electricity and water don’t mix



According to the National Electric Code (NEC), it requires a minimum of one GFCI-protected outlet per bathroom. The national recommendation is more than one, like two or three. You get to decide how many outlets you want to protect but have to have a minimum of one in your bathroom.