What pressure should my boiler be when cold?

between 1 and 1.5 bar

What pressure should my boiler be when it’s cold? The normal boiler pressure when the central heating system has cold water should be between 1 and 1.5 bar. Most manufacturers recommend an optimal system pressure of 1.3 bar .

Why is my heating system losing pressure?

The most common reasons for a boiler to lose pressure are: Releasing air or water from a radiator when bleeding it. A leak from the appliance or on the system most commonly from radiator valves or system components.

Can air in radiators cause pressure drop?

If you bled your radiators recently, you may have lost some pressure. That’s because, when you bleed a radiator, air is released, which lowers the pressure in your boiler system.

Can a faulty expansion vessel cause pressure loss?

Your combi boiler can be losing pressure for a number of reasons. Pressure loss may be caused from a leak in the pressure relief valve, an issue in the expansion vessel, air in your system, or a leak in the heating pipework itself.

What happens if boiler pressure is too low?

If the pressure on your boiler is too low, then your central heating may not work, and if it’s too high, then it will be under too much strain and could also be prevented from working.

Should boiler pressure drop when off?

What should my boiler’s pressure gauge read? When your boiler is switched off, the pressure gauge should read around 1 Bar – in the green zone on the gauge. When it is in operation (demanding heat/hot water), its pressure will increase slightly, then it should drop back down.

What can cause boiler pressure to drop?

What Causes a Boiler to Lose Pressure and How to Fix It?

  • Boiler leak. One of the most common reasons for a boiler to lose pressure is an actual leak in the appliance. …
  • A leak in the system. …
  • Faulty pressure relief valve. …
  • Damaged expansion vessel. …
  • Recently bled radiators. …
  • Broken boiler parts.


How do I find a leak in my boiler system?

Place a sheet of colored paper under the boiler – if any drops appear on the paper, it should make it very easy to find the leak in your central heating system. Follow the wet spots up along the central heating system and see if you can spot where the water is coming from.

Can a leaking radiator cause boiler pressure to drop?

Even a small leak from a radiator over time will decrease the pressure in your system and cause your boiler to switch off and display an error code for low pressure.

What are the symptoms of a faulty expansion vessel?

Big swings in central heating system pressure indicate expansion vessel faults. You probably have a failed or failing expansion vessel. An undersized vessel can cause big pressure swings too but those swings would have been present since installation.

Why does my Worcester boiler pressure keep dropping?

If you are constantly losing pressure in the heating system you could try the following to establish the cause: Check all visible joints including radiator valves and connections for obvious signs of leakage. Ensure that there are no leaks to any underfloor pipework.

How do I know if expansion vessel failed?

An installer can usually tell if the expansion vessel has failed as the boiler pressure gauge will show a great increase of pressure as the boiler heats up. A faulty expansion vessel will not always need replacing – often it will simply need repressurising.

How do you test a boiler expansion vessel?

Quote from the video:
Quote from Youtube video: If water comes out of it it means the expansion vessel is not good so then we need to fit another one. But if the expansion vessel is okay we can just recharge it again using some Confessor.

What pressure should I set my expansion vessel to?

1 bar

Summary. Expansion vessels, also known as expansion tanks, keep the pressure in a combi boiler stable while water heats and cools. They are typically located inside the boiler casing. The typical pressure a boiler system should be set to is 1 bar.

How do you check boiler expansion tank pressure?

There are two valid checks that can be made on the pressure of the air charge in an internal diaphragm or bladder type expansion tank on a heating boiler: Disconnect the expansion tank completely from the heating system and then measure air pressure using an accurate air pressure gauge at the tank’s air valve.

How often should expansion tank be replaced?

Between five and 10 years

Between five and 10 years is the average lifespan of your tank. If your home’s water pressure matches the air pressure in your expansion tank, you can extend the life of your tank. You’ll need to replace it in some cases.

How do I know if my boiler expansion tank is bad?

If it makes a dull thud rather than a hollow sound, your tank is full of water and needs repair or replacement. You can also gauge this by feeling the tank, which will be cool where it’s holding air and warm where it’s holding water. If more than half the tank is warm, you have a problem.

What happens if expansion tank pressure is too high?

With the required check valves and backflow preventers in place, your water pipes, water heater and even some appliances must deal with the increased pressure caused by thermal expansion. This causes unnecessary wear-and-tear which can result in damage to hot water-use appliances, including your water heater.

How much air pressure should be in a boiler expansion tank?

Expansion tanks are pre-charged with a 40 PSI air charge. If the inlet water pressure is higher than 40 PSI,the expansion tank’s air pressure must be adjusted to match that pressure but must not be higher than 80 PSI.

Should an expansion tank be full of water?

Checking Your Water Pressure



You can also check your expansion tank’s pre-charge pressure by knocking on the side of the tank with your knuckles to determine if it’s full of air or water. Pre-charge pressure that’s too low may be indicated when the tank is full of water.