Yes, an AFCI and/or AFCI/GFCI Receptacle can be used on a circuit with shared neutrals on the line side.

Can you share neutrals with AFCI breakers?

Can the AFCI with shared neutral be used for retrofit installations? Yes, for retrofit installation, GE AFCIs can be substituted for the existing thermal magnetic breakers without the need to sort out existing shared or mixed neutrals.

Do arc fault breakers require a dedicated neutral?





To meet the latest version of the NEC, if AFCI protection is required on the shared neutral circuits being wired, you will be unable to use a 1-pole AFCI breaker, because it requires a dedicated conductor for the line and neutral.

Can branch circuits share a neutral?

A multiwire branch circuit is a branch circuit with a shared neutral. This means there are two or more ungrounded (hot) phase or system conductors with a voltage between them and a shared neutral.

Can I put an AFCI anywhere into the circuit?

AFCIs (Arc Fault Circuit Interrupters) can be used anywhere but the Bathroom and Kitchen.

Do they make tandem arc fault breakers?

Siemens introduces new Tandem Combination Type Arc Fault Circuit Interrupters (CAFCI), expanding the capabilities of the CAFCI, designed to allow one breaker to feed two circuits – saving on both space in the load center and installation time, while keeping safety and compliance top of mind.

How do you wire a neutral shared circuit?





Quote from the video:
Quote from Youtube video: And the other goes to a switched outlet controlled by the other pair of 3-way switches bottom Center is two black wire splice together that's just the in and out for the circuit connected to breaker.

Where are arc fault breakers not required?

AFCI protection is not required for outlets located outside or in garages or bathroom areas. (B) All 15A or 20A, 120V branch circuits supplying outlets in dormitory unit bedrooms, living rooms, hallways, closets, bathrooms, or similar areas.

Will arc fault breaker work without ground?

Do arc fault breakers work with circuits that do not have a ground? Resolution: Yes, it will work as long as the circuit is grounded and it has a segregated neutral. Absence of a ground wire will not affect performance of the AFI or CAFI breaker.

Do AFCI breakers need to be grounded?

Eaton recommends the use AFCI in older homes with knob and tube wiring systems. Although these systems have no grounding conductors in the branch circuits, you can still use AFCI. An AFCI does not need a ground for proper operation.

Can you put a AFCI outlet on an AFCI circuit?



Yes, they both can be used on the same circuit; however, the Dual Function AFCI/GFCI Receptacle offers the option of providing both AFCI and GFCI protection in a single device.

Can you split a AFCI outlet?

It can indeed use two single pole breakers as the disconnecting means, as long as the breakers are connected using identified handle ties or a master handle (NEC 2008 225.33(B)). However, this would not be an option when dealing with AFCI or GFCI breakers.

Where should you install AFCI outlets?

AFCI outlets are recommended for the following locations in a house: family rooms, dining rooms, dens, bedrooms, closets, hallways, recreation rooms, sunrooms.

Does Square D make a tandem arc fault breaker?



Square DHomeline 15 Amp 20 Amp Single-Pole Tandem Circuit Breaker.

What is a piggyback breaker?

In the space of one 1″ breaker, fits two breakers side-by-side (Twin) or over/under (Piggyback).

What is a combination type AFCI?

A Combination Type AFCI detects all three types of arcing: line-to-neutral, line-to-ground, and series arcing.” The most probable and convenient “means” to meet the AFCI Protection requirement for new construction dwelling units is through use of a Combination Type AFCI Breaker, 210.12(A)(1).

What is Branch Feeder AFCI?

A branch/feeder AFCI is designed to handle parallel faults in a circuit, such as a fault in an NM cable where a staple driven too deep into the wood stud damaged the hot and neutral conductors within the cable, causing arcing with a level of approximately 75 amperes or higher.

Where are combination AFCI breakers required?



2008 Edition: Combination AFCI protection is required in all single-phase, 15-amp, and 20-amp non-ground fault circuits supplying power to living areas including living rooms, rec rooms, family rooms, dining rooms, libraries, bedrooms, sun rooms, hallways, closets, and similar areas.

What special consideration should be made when installing AFCI breakers?

Direct wired hot and neutral wires on the circuit you’re going to protect are the only physical requirement.

Where are AFCI breakers required 2020?

AFCI current requirements in the NEC 2020 code:



Common rooms. Hallways and closets. Kitchens. Laundry areas.

Does microwave need AFCI?

A dedicated 20-amp circuit is needed to feed the microwave oven. Since the appliance is plugged into an outlet, AFCI protection is required.