Can you vent a high efficiency furnace and water heater together?

Vent connectors serving equipment vented by Natural draft (typical water heater) Shall Not Be Connected Into Any Portion of Mechanical-draft systems (80% and higher efficiency gas furnaces). This Means: With Any New Furnace Installation — A Gas Water Heater Must Then Be Separately Vented.

Can furnace and water heater share intake vent?





Can A Furnace And Hot Water Heater Really Share A Vent? In short, yes. However, there are certain factors that allow a furnace and hot water heater to share a vent – this is very important to know. Firstly, the type of furnace and hot water heater play a big role in whether these two systems can share a vent.

What type and size of vent is required for a water heater?

For most installations, a 40–gallon water heater with a 3–inch outlet on the draft hood is required to have a vent connector that is a minimum of 4 inches in diameter. That means the vent connector has to increase in size by 1 inch.

Can I vent my water heater horizontally?

The venting can run either vertically or horizontally with a longer line to help with space and sizing issues within your home, which makes power vent water heaters more flexible to install. Power vents are a more efficient option, as they are designed to utilize heat from the exhaust to heat water for energy savings.

How high does a water heater vent need to be?

For a single-wall pipe, you need 6″ clearance, and you cannot pass it through a ceiling, floor, or wall unless it’s masonry or concrete (non-combustible). For the draft hood connection, you need to allow for at least 12″ of vertical vent before throwing an elbow fitting in the line.

Can you put a power vent on a water heater?





Power vents simplify a gas hot water heater installation



Reduce high electric bills by replacing an electric water heater with a natural gas or propane heater, then reduce installation costs by installing a power-vented model that can be easily vented out a sidewall.

Can a tankless water heater share vent?

No common venting.



The tankless heater cannot share vent piping with any other appliance, and it cannot use a masonry chimney flue for venting.

Do gas water heaters need fresh air?

In addition to venting, gas and propane water heaters need an air supply for combustion. This may come from the atmospheric air in the house, or it can come through a vent pipe that pulls air from the outdoors.

Can you vent a tankless water heater into furnace vent?

When installing a tankless water heater, you have to consider the type of heater to guide you on what kind of venting you will need. Since a high-efficiency gas water heater produces corrosive combustion gases, you should avoid connecting it with the furnace vent or other existing vents for other appliances.

How far can you vent a direct vent water heater?



Power-vented natural gas water heaters use an electric fan or blower to push or pull combustion gases to the outdoors. This type of venting allows gas water heaters to be installed as far as 40 feet away from an outside wall and in homes without existing vertical vents.

What is code for gas water heater vent?

6.5, provided that such vents are at least 8 feet (2438 mm) from a vertical wall or similar obstruction. All other gas vents shall terminate not less than 2 feet (610 mm) above the highest point where they pass through the roof and at least 2 feet (610 mm) higher than any portion of a building within 10 feet (3048 mm).

What is the proper way to vent a gas water heater?

There should be a minimum of 12 inches of vertical venting between the draft hood outlet and the first elbow or connecter. When using direct venting, any semi-horizontal piping should have a minimum upward slope of one quarter-inch per foot.

Can I use PVC to vent gas water heater?



A standard will be needed for plastic flue pipes that should include a temperature gauge and a high limit probe. Then PVC, CPVC and polypropylene flue gas piping can be safely used on high efficiency boilers and water heaters.

What happens if a water heater is not vented properly?

A vent connector is the thing that takes the exhaust gases from the top of the water heater (draft hood) to the vent. If a vent connector isn’t properly installed, the potential for the water heater to backdraft increases.

How do you vent a direct vent water heater?

Quote from the video:
Quote from Youtube video: Through a chimney power vent and direct then use fans to push exhaust through vent pipes. And can usually be vented either vertically through a roof or horizontally through a sidewalk.

What is the minimum access clearance on the burner side for a direct vent water heater?

It is recommended that a minimum clearance of four (4) inches (10.2 cm) be provided on the side of the water heater for servicing and maintenance of the combination temperature and pressure relief valve.

What is the difference between a direct vent and power vent water heater?



Basically, the difference between the two is that the power vent water heater removes combustion gases from the atmosphere via a powered venting fan, while a direct vent water heater vents these gases into the outdoor atmosphere using a chimney or exhaust pipe.

Are direct vent water heaters more efficient?

A power vent water heater also offers more energy efficiency when compared to a direct vent water heater. By utilizing a fan to operate the power vent, your water heater will require less gas to operate, which means it will require less energy to operate, and it will cost less to operate.

Can I replace a direct vent with a power vent?

A direct vent system pulls in air from outside and then vents the exhaust through a horizontal pipe. This difference in operation means that you can install a direct vent system almost anywhere, but a power vented water heater must be placed in a room with adequate airflow.