In general, yes. GFCI outlets have LINE and LOAD terminals. You can connect several more outlets on the LOAD terminals, and they will also be protected from ground faults. You can also add a switch, though bear in mind that highly inductive loads (like a large motor) can cause nuisance tripping of the GFCI.

Can I wire a light after a GFCI outlet?

Electrically there is no problem with powering the light with the hot and neutral feed to the GFCI receptacle. You could use pigtails to the receptacle line (and not use the load connection) and to the light switch so the lights would’t go out if the GFCI receptacle tripped.

Can I run power from an outlet to a light switch?





Adding an electrical outlet next to an existing light switch is easy, as long as there is a neutral wire in the box. Step 1: Turn the power supply off to the light switch at the main electrical panel. Step 2: Remove the switch plate and unscrew the switch from the outlet box. Step 3: Pull the switch out from the box.

Can you have a switch after GFCI?

After hooking up the switch and GFCI and plugging in the fountain…..you will need to: Turn ON the Breaker…. Fountain should be working now with the switch operating the receptacle…… the GFCI will still be latched so the wall switch will still turn it ON/OFF without having to reset the GFCI…..

How do you hook up a light switch to a GFCI outlet?

In other words, the outlet in GFCI can be turn ON/OFF via upper switch in the GFCI combo. To do this, simply connect the upper wire (there are two builtin wires on the back side of GFCI) to the line terminal of GFCI while the second wire should be wired to the incoming line (phase, live or hot) wire.

Can you have lights on a GFCI circuit?

This is because GFCI (ground fault circuit interruption) protection is only required for outlets and switches, not light fixtures unless they are above the shower area.

How do I wire a receptacle from a light outlet but keep it hot when light is off?





In this case, you must change the cable from the switch to the light outlet from a 2-wire to a 3-wire cable. As you can see, connecting a receptacle to the light would see the receptacle only hot when the light switch is on.

Can you wire a light and switch from an outlet?

Run a cable to the light fixture and another cable to the outlet from which you’re drawing power. Turn off the power to the outlet, and before making connections, test the leads with a voltage tester to make sure they’re dead. At the outlet, you connect the cable to the load terminals.

How do you wire an outlet and a light switch in the same box?

Quote from the video:
Quote from Youtube video: Put those together. Then i'm going to take my two ground wire pigtails. And combine. Those with my two ground wires coming out of the box.

Can you wire a plug socket from a light switch?

If there is only a single cable into the box, where the brown goes into COM on the switch plate and the blue goes into L1, the blue is switched live and is NOT neutral. If this is the case you most definitely cannot safely add a socket.

Is there a difference between GFI and GFCI?



Ground fault circuit interrupters (GFCI) and ground fault interrupters (GFI) are the exact same device under slightly different names. Though GFCI is more commonly used than GFI, the terms are interchangeable.

Does power go to line or load on GFCI?

Quote from the video:
Quote from Youtube video: But when it comes to actually hooking up the wire. Line means on the gfci. Receptacles that this is the power coming from the panel the electrical panel that's in your house.

What happens if you switch line and load on GFCI?

If you miswired the GFCI it may not prevent personal injury or death due to a ground fault (electrical shock). If you mistakenly connect the LINE wires to the LOAD terminals, the GFCI will not reset and will not provide power to either the GFCI receptacle face or any receptacles fed from the GFCI.

Can you pigtail a GFCI outlet?



If the GFCI outlet detects a difference between the current exiting and returning, the GFCI breaker trips. A GFCI protects multiple outlets when the wires twist together with a jumper wire, called a pigtail, and the jumper wire connects to the GFCI.

Can you have 2 GFCI outlets on the same circuit?

Having 2 GFCIs on the same circuit has no added benefit and can cause the occupant confusion when it comes to tracking down a tripped GFCI outlet. When the GFCI is installed on the lead outlet, there is no need to wire multiple GFCIs on the same circuit for residential use.

How many outlets can you run off a GFCI?

There’s no limit. A standard GFCI will protect up to 20 amps, drawn from any combination of receptacles, either the built-in one or any number of additional ones connected to its load terminals.

Does a bathroom GFCI need to be on a dedicated circuit?

Bathroom Electrical Code Requires AFCI and GFCI Protection



Ground fault circuit interrupters (GFCIs) have long been required in bathrooms, but since 2014, the NEC has required arc-fault circuit interrupter (AFCI) protection in every lighting and outlet branch circuit in the house, which includes the bathroom.

Can you have too many GFCI on one circuit?



Sometimes you need to have multiple GFCIs on the same circuit because you can’t protect the downline, e.g. if the last receptacle on the circuit is a refrigerator, radon pump, furnace in the snow belt, or other safety system where a nuisance trip would cause serious problems. In that case, attach all wires to LINE.

Can you daisy chain GFCI outlets?

Daisy chaining GFCIs does not increase protection. In industrial and commercial installations, GFCI devices may be daisy chained, but the upstream GFCI devices usually are set to a higher trip point while the downstream GFCI devices protecting point-of-use receptacles is set to the standard 6mA.

How many outlets can be on a 15 amp circuit?

8 outlets

Technically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a maximum of 8 outlets for a 15 amp circuit.