Yes. NM cable may be exposed in attic. This is very common in modern dwellings.

Can nm wire be exposed?

The National Electrical Code forbids the use of NM cable in situations where it is exposed in a manner where physical damage is possible.

How do I run NM cable in my attic?





Cable run across the top of joists

If the attic is accessible by permanent stairs or ladder, any cable running across the top of joists will have to be protected. Protecting the cable is as simple as installing “substantial guard strips”, which can simply be a 1×2 furring strip on each side of the cable.

Can Romex be next to insulation?

Romex can be installed above or under the insulation. It is OK to touch the outer jacket with your bare hands provided the insulation is not damaged. A good rule of thumb when working with electricity is to wear insulated (rubber sole) shoes and to always keep one hand in your pocket.

Where can NM cable not be installed?

Type NM cable shall be permitted as follows: For both exposed and concealed work in normally dry locations except as prohibited in 334.10(3) To be installed or fished in air voids in masonry block or tile walls.

How do you protect exposed nm wire?





Nonmetallic-sheathed cable must be protected from physical damage by rigid metal conduit (RMC), intermediate metal conduit (IMC), Schedule 80 PVC conduit, Type RTRC-XW conduit, electrical metallic tubing (EMT), guard strips, or other means approved by the authority having jurisdiction (AHJ) [334.15(B)].

Does electrical wire in attic need to be in conduit?

No, conduit is NOT required in attics. Not unless conduit is required in your area. There are other factors involved in wiring in attic spaces, but your question is a bit too vague to go into that.

Can you lay insulation over electrical wires in attic?

Yes, you absolutely can. You can lay insulation around the junction boxes as well. Making sure that the insulation is of a fiberglass material will not only ensure a fireproof setup but also reduce airflow from the home through the attic.

Is it safe to run extension cord in attic?

DON’T use extension cords to connect wires in the attic or above suspended ceilings/ANYWHERE. These are just accidents waiting to happen. A common violation is found in the installation of ceiling-mounted electrical equipment like projectors in training and meeting rooms (as in the following photo).

How close can wires be to attic access?



(A) Cables Run Across the Top of Floor Joists.

Where this space is not accessible by permanent stairs or ladders, protection shall only be required within 1.8 m (6 ft) of the nearest edge of the scuttle hole or attic entrance.

Where can you install NM cable?

NM cable can only be installed in dry locations, while NMC can be installed in dry, moist, damp and corrosive locations. In addition, 334.12(B)(4) limits NM cable from being installed in wet or damp locations. The answer to most of the questions posed in the first paragraph would be easily resolved by installing NMC.

Can nonmetallic sheathed cable be installed in exposed work?



Section 336-6 permits NM cable to be installed in exposed locations and has permitted this installation technique since the introduction of NM cable into the Code in the 1930s. If installed exposed, the cable must closely follow the building surface or be installed on running boards.

Can NM cable get wet?

NEC Section 334.10(A)(1) specifically permits NM Cable in both exposed and concealed work in normally dry locations it’s actually Section 334.12(B)(4) that states NM Cable is not permitted in Wet or Damp location.

Can I use NM cable outdoors?

Answer: No, Type NM cable cannot be installed outside, regardless of the wiring method enclosing it. The installation is a damp or wet location. Reference: 334.12(B)(4) not permitted in a wet or damp location, 300.9 Raceways in Wet Locations Above Grade.

What use is NM cable suitable for?

interior residential wiring



NM Building Cable
Standard NM cable is suitable for interior residential wiring, within ceiling cavities or walls and it is known as NM-8. This type of cable cannot be used in outdoor locations or buried underground. It is approved for use only in dry areas.

What happens when Romex gets wet?

In most homes, ROMEX® wire is used for electricity, where the copper ground wire is wrapped in paper and then, in turn, wrapped in the live and neutral wires. If this wiring is exposed either through a break in the plastic coating or even at the socket, the moisture can be soaked up by the paper, creating rust.

Can exposed wire cause a fire?

When the wiring deteriorates, it leaves bits of live wire exposed. As many of us know, exposed wire creates a fire hazard. An aging system with worn-out insulation that leaves wires exposed is vulnerable to power surges, overheating, shorting out and encountering other elements in the wall that can cause a fire.

How long does it take for an electrical fire to start?

Answer: Absolutely, an outlet that has blown a fuse can start a fire. If the problem was whatever was plugged into it, and that item is no longer there, there should be no problem, but if the problem was within the outlet itself it should be repaired immediately. The time to a fire could be from 2 minutes to 2 years.

Can a water leak cause an electrical fire?



The combination of water and electricity can also pose a fire risk. Even if a leak is small, water may find its way into light fixtures and other electrical wiring. In most cases, this will cause a harmless short, but it can sometimes result in sparks that provoke a deadly blaze.

What happens when electrical wires get wet?

Water can result in an interruption that will make the outlet stop working; however, the wires that are connected to the outlet may carry a live electrical current. This current poses two serious risks – a fire risk and an electrocution hazard.

How do you dry out electrics?

Leave the device in the container for AT LEAST 48 full hours. Your device may require a longer period of time in the drying agent depending on how long and how completely submerged it was. In some cases the device may need to sit for multiple days or up to a week – WITHOUT trying to see if it will turn on again.