As long as that notch is not in the middle third of the joist span then it should be fine from a structural standpoint. Even if it is in the middle span of the joist, such a small notch is probably inconsequential so I wouldn’t lose any sleep over it.
Can you run electrical wire under the floor?
Running electrical wires between the subfloor and the surface layer of flooring is not safe, but you can run them under the subfloor itself. To do this, you will need to make holes in the subfloor, and the best place to do this is through the bottom plates of walls.
What is an NM cable?
The non-metallic (NM) designation refers to the outer sheathing that bundles individual wires together like a cable. This is in contrast to metallic sheathed cable or conduit wiring, in which the bundle of individual conductors is protected by some form of a metal coil or metal conduit.
Can Romex be exposed in crawl space?
If your crawl space is normally dry, you can use non-metallic wires such as Romex.
How do you run cable under floor?
Drill destination hole in floor. Run wire through hole. Feed the wire through the back of the outlet box, insert the box in the wall, and mount it in place. Strip the wires and attach them to the wall jack or run them to the device.
Where can you install NM cable?
NM cable can only be installed in dry locations, while NMC can be installed in dry, moist, damp and corrosive locations. In addition, 334.12(B)(4) limits NM cable from being installed in wet or damp locations. The answer to most of the questions posed in the first paragraph would be easily resolved by installing NMC.
Where can NM cable not be used?
Types NM and NMC cables shall not be permitted as follows: In any dwelling or structure not specifically permitted in 334.10(1), (2), (3), and (5) Exposed within a dropped or suspended ceiling cavity in other than one- and two-family and multifamily dwellings. As service-entrance cable.
Can NM cable be exposed?
The National Electrical Code forbids the use of NM cable in situations where it is exposed in a manner where physical damage is possible.
How do you run electrical wire under floor joists?
To run cable through a floor that contains a cross joist, cut a hole in the cross joist in the cavity closest to the cable`s entry point. Then, run the cable through the hole in the cross joist and through 1/2-inch holes in each joist between the entry point and the communications outlet.
31 ав 1998
How do you run Ethernet cable under floorboards?
Take floorboards (small sections between joists) up in between the holes to guide the cable. Brake cable outer feed through then attach cable and pull. Through hey presto job done ! End of thread job done !
Do you have to clip cables under floorboards?
Likely as not you have found a rewired house. You cannot reasonably expect cables to clipped during a rewire! On a new build installing with access then yes it is accepted that you clip cables to the joists.
See Also:
Technical discussion forums | |
---|---|
· | Other and general engineering discussions |
Archived categories |
Can flat NM cable be stapled on edge?
Flat cables shall not be stapled on edge. Sections of cable protected from physical damage by raceway shall not be required to be secured within the raceway.
When exposed type NM cable is run through a floor it must be protected by at least?
6 inches
If the NM cable is installed where it passes through a floor, the cable must be protected for at least 6 inches above the floor by enclosing it in rigid metal conduit, intermediate metal conduit, or one of the other methods previously mentioned.
What is the minimum size NM cable that can be secured exposed to the bottom side of a joist with out a running board?
Where cable is run at angles with joists in unfinished basements and crawl spaces, it shall be permissible to secure cables not smaller than two 6 AWG or three 8 AWG conductors directly to the lower edges of the joists.
Are two NM cables allowed to be supported under 1 staple?
Secure only one cable under each fastener, in most cases. Sometimes it is permissible to secure two 2-conductor (plus ground) cables under a single staple, for example, but it is preferable not to double up cables. It is not permissible to secure more than one 3-conductor cable under a single staple.
How often does NM cable have to be supported?
every 4 ½ ft.
NM cable must be supported and secured every 4 ½ ft. and within 12 inches of every outlet box, junction box, cabinet, or fitting. Secure and support. Where nonmetallic cable is installed horizontally through holes or notches in framing members, it is considered supported and not required to be secured.
Can low voltage wire be exposed?
In general, cables can be run exposed for just about anything. For power and lighting circuits, the exposed cable can not be “subject to physical damage” (true also for flex conduits and sch 40 PVC).
Does low voltage cable need to be in conduit?
Low-voltage wiring shall not be strapped to conduit. Low-voltage wiring shall not be attached to sprinkler piping.
Can low voltage wire start a fire?
When several things line up and goes wrong, low voltage wiring can cause fires, explosions and shocks under the right conditions. When indoor rated system get soaked with water due to power surge and lightning.