Is a sub panel considered a feeder?

The definition of a feeder also includes the conductors from the source of a separately derived system or other non-utility power supply source and the final branch circuit overcurrent device. A Type SER cable between a 200-amp residential service disconnect and a subpanel is a feeder.

Can you feed a sub panel off a sub panel?





Answer: Yes. The main electrical service panel is where branch circuits originate.

Can you put a breaker on a timer?

If you mount it to the side of the breaker panel with a tiny piece of conduit you can probably just disconnect the wire from the breaker and run it to the timer without having to extend it. Then just run a new neutral and ground in to the timer and a new hot wire from the breaker to the timer.

Does an outdoor sub panel need a main breaker?

The subpanel may be equipped with a main breaker to allow for power interruption without having to go back to the main panel, but it is not required to have a main shutoff circuit breaker, since the feeder breaker back in the main panel serves this function.

What type of feeder is used for a subpanel?

The subpanel is fed by a double-pole 240-volt breaker at the main service panel, and this single feed circuit is divided into additional branch circuits at the subpanel.

How do you feed a sub panel?





Quote from the video:
Quote from Youtube video: So here we can see the circuit that we brought over this one right here is to create space in the panel. And this one is for the sub that feeds the sub. So we got to feed our new breaker.

What is the 6 breaker rule?

The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.

Can you run a 100 amp sub panel off a 100 amp subpanel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

Can you run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

Where should feeder wires to a subpanel be connected?



Quote from the video:
Quote from Youtube video: The wire. Into the sub panel from the main panel. So we'll be running our six gauge ground wire. And our feeder wire next this is three gauge like I mentioned earlier anything six gauge or smaller.

How do you feed a subpanel from the main panel?

Quote from the video:
Quote from Youtube video: Goes into the panel. And on to the ground burn. Everything is connected ready to heat this up at the main panel we've completed the other panel. We've completed this panel.

How do you wire an outdoor subpanel?

Quote from the video:
Quote from Youtube video: And backfilled it was finally time to wire up the sub panel for the soap shed. And officially juice it up it took a little time working the large gauge wiring into the panel.

Can you get 220 from a sub panel?



If it’s on a double pole breaker, it probably has 220v available even if it’s not currently being utilized. Another visual check would be to pull the cover off the garage subpanel, and see what wires are coming in. If there are 4 wires coming in (may be 3 insulated wires and bare ground) you likely have 220.

Does a subpanel need a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building.

What is the difference between a panel and a sub panel?

A main panel is an installed box where the power from the utility company enters the premises. A subpanel is an installed features that acts as a middle ground for the main panel and other types of circuits that are connected to your property.

Why would I need a sub panel?

An electrician might add a sub panel to take the load off of the main circuit breaker panel. This can prevent overloading the electrical system and tripping circuit breakers or melting fuses. Sub panels are also used to separate the electrical needs of specific areas.

How far can a subpanel be from the main panel?



The right feet would be between 4.5 to 5 feet.



The cable running from your main panel to the subpanel depends on the amperage rating. For instance, for a 30A panel, use a 10 AWG, three-wire conductor.

How many amps can a subpanel be?

The limit is that the breaker in the main panel to supply the subpanel has to be 90 Amp or smaller. What number of 15 and 20 amp 120 volt breakers can I use in the sub-panel? As many as you want.

Can I run a sub panel off a 30 amp breaker?

Quote from the video:
Quote from Youtube video: So if you needed a 30 you would want to go no less than a 50. Here. We've got a three wire with a ground number 10 set that is feeding our panel for 30 amps.

How big of a sub panel can I run off a 200 amp service?

Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.