All 15-amp and 20-amp, 120-volt receptacles must be GFCI-protected. Protection may be provided by a GFCI receptacle or a GFCI breaker. One receptacle is required at the front and rear of the house and at a maximum height of 6 feet 6 inches above grade (ground level).

Do all outdoor outlets have to be GFCI?

Outdoor electrical outlets differ from indoor outlets because they have watertight covers that protect the outlet even with a cord plugged in. Plus, the National Electrical Code requires all outdoor outlets to be GFCI outlets (ground fault circuit interrupter outlets).

How high does an outdoor outlet have to be?





6 1/2 feet

Homes must have at least one outdoor receptacle at the front and rear of the house. They must be readily accessible from the ground and positioned no more than 6 1/2 feet above grade (ground level).

How many outlets can you have on a 20 amp service?

The answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.

Can 14 2 wire be used for outdoor outlets?

If the outlets are on a 20-amp circuit, 14/2 wire is not sufficient. You will have to step up to 12/2 wire for all outlets on 20-amp circuits. Using 14-gauge wire (such as 14/2) to wire outlets on a 20-amp circuit can result in overheating and a dangerous electrical fire.

Do outdoor outlets need 20 amps?





Required Outdoor Receptacle Locations



All 15-amp and 20-amp, 120-volt receptacles must be GFCI-protected. Protection may be provided by a GFCI receptacle or a GFCI breaker. One receptacle is required at the front and rear of the house and at a maximum height of 6 feet 6 inches above grade (ground level).

In what year GFCI protection is required for most outdoor receptacles?

All outdoor receptacles were first required to be GFCI-protected by the 1971 edition of the National Electrical Code (NEC).

What is the NEC code for outlet height?

Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of the receptacle outlet box nor less than 15 inches (381 mm) measured from the bottom of the receptacle outlet box to the level of the

What is the code for electrical outlets?

The US National Electrical Code, Section 210.52, states that there should be an electrical outlet in every kitchen, bedroom, living room, family room, and any other room that has dedicated living space. They must be positioned at least every twelve feet measured along the floor line.

What is the code for garage outlets?



What is the code requirement for electrical outlets in your garage? While your state may be different, most states employ the 2020 NEC requirement that you have one 120-volt, 20-ampere branch outlet for each vehicle bay that is placed at least 5.5 feet above the floor.

Does outdoor electrical wire need to be in conduit?

Local codes typically require conduit protection for exterior wiring if the wiring is installed above ground. If you are burying the wiring, most codes allow for underground fed cables, but some will require the use of a conduit. Buried or exposed wiring will need to be listed for its application.

Can you run Romex outside?

Yes, they can be used outdoors, it is better to be safe than sorry. We recommend using a conduit when running the wire underground. Not only is it code, but also a good practice to ensure long life of the wire.

How far can I run a 20 amp circuit on 12 gauge wire?



After these distances, the circuit will go over the recommended 3% voltage drop. You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

Does an outdoor outlet have to be on its own circuit?

Senior Member. You can come off any non dedicated space circuits. Some companies come off one of the garage circuits. But if you’re doing large houses.

Do outdoor receptacles need AFCI?

AFCI protection is not required for outlets located outside or in garages or bathroom areas.

Is it OK to put a 20 amp outlet on a 15 amp circuit?

According to National Electrical Code, only a 15-amp or 20-amp electrical receptacle can be installed to a 20-amp circuit. A 15-amp receptacle may also be installed on a 15-amp circuit. However, a 20-amp GFCI outlet may not be installed to a 15-amp circuit.

Can you use 14 gauge wire on a 20 amp breaker?



NO! You cannot use any 14 gauge wire on a 20 amp circuit.

What wire do you use for 20 amps?

12-gauge

A 20-amp circuit, protected by a 20-amp breaker or fuse, must be served by 12-gauge or 10-gauge wire.

Can I use 12-gauge wire on a 15 amp circuit?

Because it has even less chance of overheating, 12-gauge wire is also acceptable on a 15-amp circuit.

How far can you run 12 gauge wire without a voltage drop?



As an example, for a 120-volt circuit, you can run up to 50 feet of 14 AWG cable without exceeding 3 percent voltage drop.



For 240-volt circuits:

14 AWG 100 feet
12 AWG 120 feet
10 AWG 128 feet
8 AWG 152 feet
6 AWG 188 feet


How far do electrical outlets need to be from the floor?

As for typical heights, that isn’t as well-regulated (and we’re glad for that). Generally, you want to mount receptacle boxes with the bottom of the box about 16-inches off the floor. Coincidentally, this roughly equates to the same height as your garden variety 22-ounce framing hammer.