Can you run Romex through cold air return?

On the other hand, it’s common practice to run Romex perpendicularly across a panned stud cavity or joist bay used as a cold air return duct. In such a case, we drill into the framing on both sides of the panned return, pull the cable through the holes, then seal the holes around the Romex with caulk.

Is it OK to run wire through cold air return?





Re: Electrical wire crossing cold air return duct
In any event it will not hurt anything to be on the safe side.

Can you run Romex in plenum?

Regular type NM cable (what’s generally called Romex) is not plenum rated. Type AC cable (often incorrectly called BX) is allowed in plenums, however. The main concern is the toxic fumes that the plastics used in most wire insulation release when they’re heated or burned.

Can you run wire through air duct?

Air ducts are meant as a conduit for air, not wires. Inserting cables inside the ductwork may even violate building codes. The reason we don’t advise this is because a technician can damage the cables during an air duct cleaning. This could render your phone line, Internet, and cable television out of service.

What type of wiring should be used in ventilation ducts?

Electrical metallic tubing, rigid metal conduit, intermediate metal conduit, armored cable, metal-clad cable without a nonmetallic cover, and flexible metal conduit can be installed in environmental air spaces.

Where are wiring systems allowed in ducts?





No wiring systems of any type shall be installed in ducts used to transport dust, loose stock, or flammable vapors. No wiring system of any type shall be installed in any duct, or shaft containing only such ducts, used for vapor removal or for ventilation of commercial-type cooking equipment.

Can you run thermostat wire in a return duct?

running any kind of wire inside ductwork is a big no-no by any standard ! Difficult as it may be you need to find some kind of alternative. Been doing HVAC in new construction (Florida) for 13 years. Only exception inspectors allowed was a firestat behind a R/A grille.

Can you run electrical wire next to plumbing?

You can definitely run wires close to plumbing wires, provided you aren’t running a bare or damaged copper wire next to steel pipes. According to the code, you can run plumbing and electrical wires through the same hole, but you need to make sure the wire is well insulated and there is no risk of ruptures.

Can MC cable touch ductwork?

Armored cable is meant to resist damage to the conductors from contact with other materials (like a duct). The armor itself is grounded when properly installed, and touching other metal should pose no risk (assuming the armor is not so bent or compressed as to expose the conductors).

Can dryer vent touch electrical wires?



Long, complex dryer vents are just an invitation to problems. Having it touching the wires is likely to overheat that portion of the wires each time the dryer operates, so at minimum providing some insulation between the two would be better.

Do electrical wires need to be stapled?

In the codebook, section 334.30 states that flat cables must be stapled on the flat side of the cable, not on the edge. This provides a tight wire connection to the stud and prevents any damage to the wire sheathing.

What is plenum rated cable?

Plenum rated cable has a special insulation that has low smoke and low flame characteristics. Plenum cable is mandated to be installed in any “air handling” space. For example, most large office buildings use the ceiling to return air to the AC unit.

Which one of the following wiring methods is permitted to be installed in ducts specifically fabricated for environmental air?



Which of the following is permitted to be installed in ducts specifically fabricated for environmental air-handling purposes? A: A 3-foot-long cable (listed for use in a plenum) and installed to serve an air sensing device.

How does a plenum differ from a duct?

airflow. A plenum is an air distribution box designed for forced-air systems on residential homes and commercial businesses. It is part of the ductwork, but far different than an air duct as these important boxes handle air as it enters the ducts and helps to recirculate it within a system.

What is an NM cable?

The non-metallic (NM) designation refers to the outer sheathing that bundles individual wires together like a cable. This is in contrast to metallic sheathed cable or conduit wiring, in which the bundle of individual conductors is protected by some form of a metal coil or metal conduit.

Where is Romex not allowed?

To give you an overview of what the National Electrical Code (NEC) regulations state, Romex wire shouldn’t be left exposed anywhere in the house, be it the basement, attic, or the home itself. In other words, the installation above is not compliant with the relevant codes.

Can you run Romex in conduit?



No, you can not run your Romex wiring in conduits.

What is yellow Romex used for?

Yellow Wire
The heavier, yellow ROMEX® is rated at 20 amps. Common applications for this 12-gauge wire are receptacles and three-way circuits. Larger appliances, such as a microwave or welder, require the additional power this wire delivers.

What is blue Romex used for?

Use it for electrical wiring of bedroom receptacles terminating at AFCI (Arc Fault Circuit Interrupter). Romex SIMpull features Southwires NoLube SIM technology which has revolutionized the way wire is pulled into conduit without any pulling lubricant, saving contractors both time and money.

Can you use 12 gauge wire on a 15 amp circuit?

With 12 gauge, you need to use the screw terminals. You can use 15 amp outlets on either 15 or 20 amp circuits. 12 gauge wire is the minimum for 20 amp circuits. 14 gauge wire is the minimum for 15 amp circuits.