Does a dryer need AFCI?

No — the 2014 NEC only calls out AFCIs for 120V, 15 and 20A outlets — the dryer is 240V, so it doesn’t need an AFCI. 210.12 Arc-Fault Circuit-Interrupter Protection.

Do 240V circuits need AFCI?





Circuits that provide more than 20 amps or more than 120 volts (208 / 240 volts circuits) are also exempted from AFCI protection.

Do 220v circuits require AFCI?

NEC AFCI requirements only apply to 120V, 15/20A circuits.

Where are AFCI not required?

Exception: AFCI protection shall not be required where the extension of the existing branch circuit conductors is not more than 1.8 m (6 ft) and does not include any additional outlets or devices, other than splicing devices.

Does dryer need AFCI GFCI?

There are no conditional distances in those spaces: if the receptacle is installed in the laundry room/area, it requires GFCI protection. Therefore, clothes dryers are now required to be GFCI protected because they are in the laundry area.

Do electric ranges need AFCI?





AFCI protection is generally required for all lighting circuits.

Does a furnace need arc fault protection?

Yes, you need AFCI protection. As of the 2017 NEC, AFCI protection has been extended to all 15 and 20A, 120V branch circuit outlets in all dwelling unit locations. This includes dedicated appliances such as furnaces and dishwashers, and even smoke detector circuits.

Where are AFCI breakers required 2020?

AFCI current requirements in the NEC 2020 code:

Common rooms. Hallways and closets. Kitchens. Laundry areas.

What requires AFCI breaker?



AFCI protection is currently required for all 15 and 20 amp branch circuits providing power to outlets* in residential family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, and similar rooms or areas.

Do lighting circuits need to be AFCI protected?

AFCI requirements.

The NEC requires that virtually all branch circuits for lighting and receptacles in a home must have arc-fault circuit-interrupter (AFCI) protection.

Does microwave require AFCI?



A dedicated 20-amp circuit is needed to feed the microwave oven. Since the appliance is plugged into an outlet, AFCI protection is required.

Can I use AFCI outlet instead of breaker?

AFCI outlets work with any type of wiring and are not dependent on the type of breaker in the panel. They are also easily accessible and have a level of familiarity with users with the TEST and RESET buttons that are also present on GFCI outlets.

Can you put a AFCI outlet on an AFCI circuit?

Yes, they both can be used on the same circuit; however, the Dual Function AFCI/GFCI Receptacle offers the option of providing both AFCI and GFCI protection in a single device.

Should I upgrade my breakers to AFCI?

People who should STRONGLY consider AFCI retrofitting when not required by scope of other work requiring code updates would be those with 15 & 20 amp circuits on the problematic old Aluminum wiring (1960’s era, vaguely) that is a particular fire hazard, and those with other “very elderly and suspect” wiring.

Does a washing machine need to be arc fault protected?



Nearly every room/ area in a dwelling unit requires AFCI protection, so no matter where you put a clothes washer, it will be AFCI protected in a newer home.