Why do some outlets have a horizontal slot?

This orientation would reduce the chance of metal (bracelet or necklace) contacting the line and neutral when plugging or unplugging a cord. Screws on each side are connected together by a metal tab that can be removed to isolate the screws.

Can outlets be mounted horizontally?





The electrical code allows outlets to be installed with the ground plug hole facing up, down or sideways. It’s up to you, there is no standard electric outlet orientation. So that means there really is no such thing as upside down outlets.

Can you install an outlet on a flat surface on the kitchen counter?

Be no higher than 20 inches above the countertop surface. Receptacles are NOT allowed below a countertop extending more than 6 inches beyond its base. Be permitted to be installed within the surface of the countertop or work surface if the outlet is listed for such an installation.

Are outlets in the floor Code?

The National Electrical Code requires floor outlets to be a part of an approved assembly consisting of a metal box, gasket seal, special receptacle and strong cover plate with a moisture-proof cover. You can’t just mount a regular wall outlet in the floor.

Why do plugs have two holes in the blades?

Rather than having deliberate gaps in the middle of the metal, the design used to feature semi-circular indents on either side of the plug. These indents were designed to hook the plug to the socket and prevent it from falling out.

What are sideways plugs called?





20-amp receptacles have a horizontal slot branching off one of the vertical slots. Appliances, such as microwaves, often have 20-amp plugs and must be plugged into a 20-amp outlet. Electrical plugs designated as 20-amp will not fit into 15-amp outlets.

Why do electricians install outlets upside down?

Easier to Identify Switched Outlets

Electricians may position the outlet in an upside-down position so that you can quickly identify the switch-controlled receptacle. Since it stands out visually to most people right away – it provides convenience to the occupants to easily remember which outlet is switch controlled.

Why are outlets upside down in hospitals?

Because if a cord or wire were to fall down on a partially plugged in right-side up outlet you would short out between the hot and the neutral. When the outlet is “upside down” in the above situation the wire would touch ground first.

Can you mount electrical boxes sideways?



The NEC (National Electric Code) does allow an electric panel to be mounted horizontally, but only if vertical mounting is not possible due to space limitations or otherwise impractical (NEC 240.33).

How close does a floor outlet need to be to the wall?

Receptacles must be installed so that no point measured horizontally along the floor line in any wall space is more than 6 feet or 1.8 meters from an outlet in that space. Following the floor line from a doorway, fireplace or similar opening, the maximum distance to a receptacle is 6 feet (1.8 meters).

How far off the floor should electrical outlets be?

about 16-inches



As for typical heights, that isn’t as well-regulated (and we’re glad for that). Generally, you want to mount receptacle boxes with the bottom of the box about 16-inches off the floor. Coincidentally, this roughly equates to the same height as your garden variety 22-ounce framing hammer.

Where should I put my floor outlet?

Floor Outlets

Install a few extra outlets near the floor and eliminate the need for extension cords. You can even consider installing outlets directly in the floor, to further reduce tripping hazards. The National Electrical Code has certain requirements when it comes to floor outlets.

Are outlets allowed in baseboards?

By installing electrical outlets in the baseboard molding of your home they can seamlessly integrate into a design element that almost camouflages the outlet. By doing this small detail, you can eliminate the presence of noticeable unsightly cords and wires from your home.

Do floor outlets need to be GFCI?



There is no code requirement for all floor receptacles to be GFCI-protected. But when they are in a location requiring GFCI, such as a bathroom, then it is necessary.

Do floor outlets need covers?

It’s important to cover an electrical floor outlet any time it’s not in use in order to avoid damaging the outlet itself or causing electrical problems. In fact, properly covering the electrical outlet in your floor may even prevent a fire.

Can I put a rug over a floor outlet?

If you are not going to use the floor outlet at all, covering it with a movable rug is OK. But you should never cover an outlet or junction box of any type (e.g., including if you removed the outlet, capped the wires and put on a blank plate) with any permanent flooring like wall-to-wall carpet.

Can you cover a floor outlet?

Cover the floor outlets with a Rubber Mat – placing a rubber mat over a socket is also a great method of protecting it. Plus, rubber is a weak power conductor, so it is able to prevent electrocution in case of an outlet malfunctioning.

How helpful is a floor outlet?



Floor outlets are electrical outlets that are installed into a floor area rather than into a wall. Often, a floor outlet will be equipped with a metal plate to protect the outlet and wiring, along with a cover that prevents dust and other material from collecting in the outlet when the device is not in use.

What is a ground outlet?

Modern, grounded 120-volt receptacles, also referred to as outlets, in North America have a small, round ground slot centered below two vertical hot and neutral slots, and it provides an alternate path for electricity that may stray from the appliance.

What is convenient outlet?

Definition of convenience outlet

: a receptacle in a wall or baseboard for connection to lamps or other electrical appliances.