Do I need a subpanel?

If your home’s electrical service panel (breaker box) is full and you need more room to add new circuits, installing a subpanel might be the way to go. Subpanels certainly can add convenience and plenty of room for installing new circuits, but your current system must have enough capacity to support a subpanel.

What size subpanel do I need?





Subpanel Circuit Breaker Sizing
To calculate the breaker size, simply divide the adjusted wattage by 240 volts to find the rated amperage needed for your subpanel. Often, the result is not a common circuit breaker size. and you can simply round up to the next higher size of ​the breaker.

How many circuits can be on a 60-amp subpanel?

Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

When should an electrical sub panel be installed?

An electrician might add a sub panel to take the load off of the main circuit breaker panel. This can prevent overloading the electrical system and tripping circuit breakers or melting fuses. Sub panels are also used to separate the electrical needs of specific areas.

What is the electrical code for sub panel?

___ NEC 110.26(A) – The working space about electrical service panel/sub-panel shall be at least 3 ft. in front of the electrical panel. The width of the working space shall be 30” or greater, and the height of the space shall extend from the floor to 6 1/2 feet or the height of the panel, whichever is greater.

How many circuits can a subpanel have?





A true subpanel is a smaller circuit panel breaker with four to 24 slots that is fed from a 240-volt circuit breaker in the main panel, known as a feeder breaker.

What is the smallest sub panel I can install?

An electrical sub panel can vary in size and purpose. A 100 amp circuit is the minimum in most states, although with all the new electronic devices (computers, printers and TVs), air conditioning and electric heat, we suggest 200 amps especially for new homes.

How many circuits can be on a 50 amp sub panel?

A single receptacle has a maximum power draw of 1.5-amps, so, only use 26 outlets at most for a 50-amp breaker (40-amps ÷ 1.5-amp = 26.67 outlets).

How far can subpanel be from main panel?

The right feet would be between 4.5 to 5 feet.
The cable running from your main panel to the subpanel depends on the amperage rating. For instance, for a 30A panel, use a 10 AWG, three-wire conductor.

Can you wire a subpanel with 3 wires?



Another way to wire a subpanel was with a three-wire feed; two hots and a neutral, with grounds and neutrals connected together at the subpanel. In this case, the grounds and neutrals have to be connected together.

Does a subpanel need a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building.

Can I use a main lug panel as a subpanel?

The main circuit breaker provides a level of overcurrent protection for all branch circuits, as well as a single disconnect means for all loads being fed by the load center. Main lug only load centers are typically applied downstream of a main circuit breaker panel and are often referred to as a sub panel.

Can you run a 100 amp sub panel off a 100 amp main panel?



Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A.

How high does a sub panel have to be off the ground?

All electrical panels must have a minimum of 36 inches of clearance in front of the panel, 30 inches of clearance across the face of the panel, and a minimum of 78 inches above the floor from the top edge of the panel.

Can I use any panel as a sub panel?

There’s no problem with having a main breaker in a subpanel. It’s required if your panel is in a separate building and has more than six breakers, but there’s nothing prohibiting it in any other case.

How many wires do I need to feed a subpanel?

A subpanel requires two hot wires connected to a 240-volt double-pole breaker in the main panel. It also needs a neutral wire and a ground wire. The cable used for this run is known as a “three-wire cable with ground.” The two hot wires, called feeder wires, will provide all of the power to the subpanel.

Can I run a 100 amp sub panel off 200 amp main?



Can you add a 100 amp breaker to your main panel? Yes you have 12 slots the double pole breaker will only take 2 slots.

Can you run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

How big of a subpanel can I install off a 200 amp service?

Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.

What size wire do I need to feed a 200 amp sub panel?

The 250 KCMIL wire is the perfect size wire for 200 amp service because it has 255A ampacity (a minimum of 250A ampacity requirement is satisfied).