You need a “disconnect” that is rated at 20 amps 240 volt minimum. Be sure it is a two pole (so you can disconnect both hot wires) disconnect. You may not need a disconnect at all if the following two conditions are met, the controller is within sight of and within 50 feet of the circuit breaker for the pump.Sep 15, 2003

Does a submersible pump need a disconnect?

Submersible is one of the specific exceptions (“impractical or causes increased hazard”) to “disconnect in sight required.” However, the disconnect means should have provision to be locked in the open (“off”) position, and that locking means needs to remain in place whether or not a lock is installed.

How far away can the disconnect switch be located for the submersible pump next to the well?





The disconnect needs to be “within sight” code defines this as 50′ and being able to see it from the well.

Does a submersible well pump need to be grounded?

NEC 250.112(M) requires that where a submersible pump is used in a metal well casing, the metal well casing shall be bonded to the equipment-grounding (bonding) conductor of the circuit that supplies the submersible pump.

Does a well pump have a breaker?

Most submersible well pumps are single phase 230 volts and require a 2 pole circuit breaker (2 individual circuit breakers connected together).

Does well pump need a disconnect?

You need a “disconnect” that is rated at 20 amps 240 volt minimum. Be sure it is a two pole (so you can disconnect both hot wires) disconnect. You may not need a disconnect at all if the following two conditions are met, the controller is within sight of and within 50 feet of the circuit breaker for the pump.

Does a disconnect have to be readily accessible?





The NEC requires many things to be readily accessible. Overcurrent devices, disconnecting switches, GFCI type devices, AFCI type devices, and receptacles serving the front and back of a dwelling unit, are all items required to be readily accessible.

How low can you mount a disconnect?

The NEC does not mandate a minimum mounting height for panelboards, disconnects, or meter enclosures. But switches, and circuit breakers used as switches, shall be installed so the center of the grip of the operating handle of the switch or circuit breaker, when in its highest position, is not more than 6 ft 7 in.

How close does a disconnect have to be to a motor?

50 ft

The disconnect that is provided to meet the requirements of 430.102(A) can also serve as the disconnect for the motor if it is located within sight from and not at a distance greater than 15 m (50 ft) from the motor and equipment.

How many amps does a submersible pump need?



A 1 HP submersible pump engine will draw a 3.2-amper current if it is a single-phase motor at 230 volts of voltage. If it is a three-phase motor at 440 volts, it will draw a maximum 1.7-amper current.

What size breaker does a well pump need?

Pumps Under Full Load

Well Pump (HP) Volts (V) Circuit Breaker (Amps)
0.5 HP 110V 15A
0.5 HP 230V 15A
0.75 HP 230V 20A
1 HP 230V 25A

How much electricity does a submersible pump use?

To give you a rough estimate the average rated power of water pump is from 250 watts to 1500 watts. Smaller the water pump, less is the wattage, less is the power consumption, hence low is the discharge and head. If the rated power is given in horse power (hp) then convert it to watt by multiplying it with 746.

Does a well pump use a lot of electricity?



Well pumps use a huge amount of energy every time they start up. Well pumps should be sized by a professional. It is not uncommon for people to have 3/4 hp pumps installed in their wells equaling 30 minutes of pumping per day or 350 kWh/yr, while a ½ hp pump, which uses only 240 kWh/yr, would be sufficient.

How many hours a day does a well pump run?

How many hours does a well pump run a day? Answer: On average, it can run up to 2 and a half hours.

How do you wire a well pump?

How to Wire a Well Pump

  1. Step 1 – Disconnect All Power. …
  2. Step 2 – Ground the System. …
  3. Step 3 – Make the Wiring Connections. …
  4. Step 4 – Test the Pump Before Installing. …
  5. Step 5 – Mount the Control Box. …
  6. Step 6 – Install the Pump. …
  7. Step 7 – Clear Out the Well. …
  8. Step 8 – Attach to Water Tank.


What kind of wire do I need for a submersible pump?



For a submersible pump, you will need a UL listed Type THW submersible cable. The rating that you need is UL 83. Every UL-rated cable is flexible and protected enough to be put in a submersible pump.

What are the 3 wires on a well pump?

In a 3-wire well pump configuration, the motor is connected by a black, red, yellow, and green (ground) wire. Three-wire pumps utilize a separate control box outside the pump that houses the important starting components, which is usually mounted on a nearby wall above the ground.

How do you wire a submersible pump pressure switch?

Quote from the video:
Quote from Youtube video: Situation however the pressure switch in a three wire system is going to be located. Before your control panel and in a two wire system it's going to be located somewhere near the pressure tank.

Where is the pressure switch on a submersible pump?

You’ll find the pressure switch mounted on a 1/4-in. tube near the pressure tank. It’s what senses when water pressure has dropped to the point where the pressure tank requires more water. The switch then powers up the well pump.

Can you wire a well pump backwards?



A common myth is that in reverse rotation, the pump causes backward flow, that is, IN the discharge and OUT the suction. In reality, a pump operating in reverse rotation because of wiring or phase change will pump in the normal direction. Now, it won’t pump very well. Its flow will be reduced, as will its head.