We recommend using the brown cable for the permanent live (L), the grey cable (sleeved blue) for the neutral (N) and the black cable (sleeved brown) for the switch-live (SL).

What color wire is used for fan?

Black wire





Black wire is for the fan. Blue wire is for the lamp if one is included with the fan. White wire is neutral. Green wire is for the ground.

How do you wire an extractor fan?

Quote from the video:
Quote from Youtube video: You just take your three-cornered cable I've labeled that up there with an arrow to show that's going to the extractor fan black cable is going to be the switch life.

What color is the ground wire on an exhaust fan?

Green, Green with Yellow Stripe, or Bare Copper: Ground Wires. Green is the most common ground wire color, but green wires with yellow stripes and bare copper wires (with no colored insulation) are also ground wires.

How do you wire a bathroom extractor?

Quote from the video:
Quote from Youtube video: So the top terminals are the supply side and the bottom terminals are the load side. So the cable from the fan goes to on this side and cables to the right switch is going to this to this side so

What are white wires used for?





The white wire is the “neutral” wire, it takes any unused electricity and current and sends it back to the breaker panel. The green wire (or it can sometimes be uncolored) wire is the “ground” wire, it will take electricity back to the breaker panel, then outside to a rod that’s buried in the ground.

What are the blue brown and green wires?

Brown is your hot wire so you want to connect that to your building’s black wire. The blue is negative or return, so that will go to white. Green with yellow stripe is the ground and will go to the building green.

Can you wire an extractor fan to a light switch?

Wiring an Extractor Fan With an Independent Switch (not turned on by the light switch) As with the option above for connecting to the existing light switch, before you start any wiring, make sure that the power is off to the circuit you are working on!!

Can extractor fan be wired to lighting circuit?

Introduction. Extractor fans in bathrooms are frequently powered from a lighting circuit. This is because many include a “run on” capability that is triggered by the operation of the light switch, and it is not permitted to have a device powered from two separate circuits.

Do bathroom extractor fans need a fused spur?



2.5) and, therefore, a standard switch fused spur should suffice, unless there is a permanent live also required; in which case the switch will need to be double-pole.

Does a bathroom fan need to be on its own circuit?

Bathroom Circuits



If the vent fan has a built-in heater, it must have its own 20-amp circuit. This is called a “dedicated” circuit because it serves only one appliance or fixture. Heat lamps, wall heaters, and other built-in heating appliances may also require dedicated circuits.

Do you need an isolator for a bathroom fan?

You only need an isolator for the fan, if you want to be able to isolate the fan. There’s no law or Regulation stating you must have an isolator. In fact, unless you are wired directly to the incoming supply you have an isolator, the main switch or an MCB/fuse in you Consumer Unit.

How do you wire a fan switch?



Quote from the video:
Quote from Youtube video: And the lights to the top of the switch normally electricians will use the red wire to connect to the ceiling fan lights. And the black wire to connect to the fan.

Why are there two white wires and two black wires?

So, why are there two black and two white wires in your outlet box? There are two black and two white wires in an outlet box because the outlet is in the middle of a series circuit, accepting power from another source and sending it on. Two cables are hot wires, bringing the power in and carrying it onward to the next.

Where do you connect the pink wire?

The white wire should be connected to the white wire. If you want the wall switch to turn off the light/fan, you need to hook the pink wire in the box to the black wire on the controller. You can prevent the switch from turning off the light by connecting black to black.

What is a 14 3 wire used for?

ROMEX® 14-3 is designed for use on circuits that require 220 to 240 volts from the power panel. An example is a clothes dryer. ROMEX® 14-3 can also be used to power two different circuits. The trick is that each circuit uses a different hot wire, but they share the common wire and ground wire.

Should I use 12 or 14 gauge wire?



A 12-gauge wire is required for an outlet circuit that is regulated by a 20-amp breaker while in a case where an overloading light circuit is not required a 15-amp breaker and 14-gauge wire is necessary.

What can 14 2 wire be used for?

14/2 electrical wire can be used for outlets and lights that are on 15-amp circuits. Most commonly, it is used to power light fixtures that require low amperage. 14-gauge wire, such as 14/2, is mostly used for wiring light fixtures on 15-amp circuits. You can use 14-gauge wire for outlets on 15-amp circuits.

What is the red wire in 14 3?

A 14/3 electrical wire means that it is 14-gauge in size and it has three primary wires plus a ground wire. The three primary wires are red (hot), black (hot) and white (common). This wire is used as two 120-volt circuits that share a common return wire.

How do you wire a 14 3?

Quote from the video:
Quote from Youtube video: Right there identical. Left side left side the red wire from the 14. 3 is feeding to the right side traveler terminal number two.

What is 4 wire Romex used for?



Four-wire is used for “two-way” circuits, and for cases where two circuits are running to the same place (independent control of a ceiling fan and its lights, for example). In the US color coding conventions, red is the “second hot” needed for these applications.