Inspect the Wires in Your Furnace If your cables are looking fine, try unplugging the fan for a few minutes and then plugging it back in again. Sometimes, this process can reset the motor and solve your furnace problems. If unplugging and plugging your fan back in again doesn’t work, check the fuse box.

Why does my blower motor work sometimes?

When a blower resistor fails, the highest fan speed usually is the only one that still works because it essentially bypasses the resistor and receives the maximum amount of voltage. When the resistor is working, it reduces the amount of voltage going to the lower fan speeds so the fan runs slower.

Why does my furnace not kick on sometimes?





If your furnace is not turning on you should first check if the filter is clean. Dirty filters cause insufficient airflow and can prevent the furnace from starting. Other reasons it won’t start can stem from improper thermostat settings, forgetting to turn on the gas line, or faulty pilot light.

Why does my furnace work intermittently?

So, if your furnace keeps turning off and on too quickly, your thermostat might be malfunctioning or broken. There are several things that could be causing your thermostat to not work properly. The wiring could be old and need replacing, it might need new batteries, or it could be the location of your thermostat.

How do I know if my furnace blower motor is bad?

Signs of an Overheating Blower Motor

  1. A “hot” or burning smell from vents in the home. This symptom is often coupled with the furnace shutting off completely. …
  2. Loud humming and other unusual noises. We have many homeowners call us mentioning humming and other odd sounds. …
  3. Furnace cycles off and refuses to restart.

How do I know if I need a blower motor or a resistor?





Here are some of the warning signs of a bad heater blower motor resistor: Fan does not work at all, so no air comes out of the vents. Fan only works on some speeds and not others. Fan only works on the highest speed.

Can a bad blower motor resistor cause no heat?

Problems with Your Blower Motor or Blower Motor Resistor

The blower motor resistor is the part that controls the fan speed of the blower motor. Both of these components can fail, resulting in the heating system simply not working.

How do you trick a flame sensor?

Luckily, making such a check is very easy:

  1. Take a multimeter with microamps (µA) measuring system.
  2. Keep the furnace system turned on.
  3. Connect it to the wire that is leading to the gas valve.
  4. Connect the other side of the multimeter to the sensor terminal.
  5. Take the lead away from the flame sensor.

Why do I have to keep pushing the reset button on my furnace?



A furnace reset button is an important feature included with your HVAC system. Designed to quickly shut the unit off, the function is key to safely heating your home. If your furnace reset button keeps tripping, it’s likely that your furnace is overheating. This may indicate a need for furnace repair services.

What happens when a blower motor goes out?

If the blower motor is completely bad, then you’ll have no airflow at all. Strange sounds coming from blower. Blower motors can make all kinds of sounds, depending on what the issue is. Vibrations, grinding, and high pitched-noises are some of the sounds a blower can make if it’s going bad.

How much does it cost to replace a furnace blower fan?

Furnace Blower Motor Replacement Cost



On average nationwide, a furnace blower motor replacement costs $400 to $600, including parts and labor. A single-speed blower motor costs around $450 to replace while a variable-speed motor costs $600 or more. You’ll also need to budget labor, about $75 to $125 per hour.

Can you run furnace without blower?

The blower fan motor

The furnace can produce heat inside the combustion chamber—but that heat won’t go anywhere if the blower fan isn’t running. Because there’s a danger of the furnace overheating without the blower fan, the furnace won’t operate unless the blower has power.

How do I test my furnace blower?

How To Check your Furnace Blower Motor (7 Steps)

  1. Step 1: Turn off all power to the furnace. …
  2. Step 2: Remove the Furnace Access Panels. …
  3. Step 3: Use your voltage tester to ensure no electricity is flowing through the furnace. …
  4. Step 4: Feel the area near the blower motor to determine if it’s hot.

Should your furnace fan be on auto or on?



“auto” is the best setting for your furnace fan in the winter. It will aid in saving energy and money while also working to keep your home at an optimal temperature. However, for summer, “on” is the best setting for your furnace fan.

Why will a blower run on the on position and not on auto?

That’s because if the heater never warms up then the fan controller won’t automagically turn on the blower fan. Let me know what you find. Electric split unit trane the fan comes on in the on position but not in automatic. Heat or cool isn’t working on the condenser or evaporator .

Why is my furnace not working on auto mode?

Inspect Your Thermostat – First off, make sure your thermostat is set to the “Heat” or “Auto” setting. If that doesn’t start warm airflow, raise the temperature to the highest possible setting. Wait a few minutes to see if that sets the furnace in motion.

How do you reset furnace blower?

Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.

How do I reset my blower motor?



How to Find and Reset your Furnace Motor Blower

  1. Step 1: Turn off the power to the furnace. …
  2. Step 2: Remove the blower compartment cover. …
  3. Step 3: Make sure the blower is completely cooled off. …
  4. Step 4: Locate the reset button. …
  5. Step 5: Press the button in (assuming that this is your issue and that the button has popped).