What is the maximum distance from the bottom of the sink basin to the trap?

According to the International Residential Code, the maximum vertical distance between the sink drain and the entrance to the p-trap is 24 inches.

Does P-trap have to be directly below sink drain?





You attach the p-trap directly to the drainage and manuever the p-traps exits into you existing drain. It is not ideal to have the p-trap below the the exit drain because water gravity has to force the water out instead of it flowing downwards naturally. They both work and have seen it many times.

How far below drain can P-trap be?

UPC mandates that a washing machine P-trap must be between 6–18 inches above floor level.

How do you align a sink drain with a P-trap?

Quote from the video:
Quote from Youtube video: So you have to cut that distance such that when you slide the p-trap up against it it will be there and perfectly level to go straight into the center of that pipe.

How far can drain be from sink?

The most common kitchen counter height is 36 inches, but it can vary from 30 to 45 inches. The standard kitchen sink is 8 inches deep, which means that the normal distance between a kitchen sink drain and the floor is 28 inches. This will vary, depending on the height of the counter and the depth of the sink bowl.

What is the maximum amount of fall between a p-trap and its protecting vent?





1 – Maximum Length – Table 7.5. 6.3. 2 – Minimum Length – 2X Drain Size 3 – Minimum Fall – 1 in 50/1/4” per foot 4 – Maximum Fall – 1 x Drain Size 5 – Change of Direction – 135° Every fixture requires a vent and a trap. These rules allow the plumbing system to operate as it’s intended to.

What if new kitchen sink drain doesn’t line up with existing pipes?

In general, if the P-trap doesn’t line up with the drain, you can adjust the length and height of your drainpipes by cutting them or simply slipping them in and out of their fittings.

Does P-trap have to be level?

You must install a trap level in relation to its trap seal. If the trap isn?t level, it can be susceptible to back-siphonage.

Do you need P-trap for kitchen sink?

Even if you are meticulous about never dropping things down the drain, you still need a p-trap under your sink to keep gas out. Sewer gases can rise through the drain pipes in your home, but the u-shaped bend in the p-trap collects water. This water blocks the gases from rising up into your sink.

Do flexible P traps work?



P-traps take on and maintain the shape of a letter p to keep sewer gases out of your house. When you use a flexible p trap, you’re more likely to get the shape wrong, and you’re more likely to accidentally misshape it when you bump the pipe. Or when you bump it, the force might cause it to spring a leak.

Why does P-trap leak?

When a P-trap leak occurs, it’s usually because the nuts aren’t tight enough, the pipes are misaligned or a P-trap washer isn’t seated correctly.

Can sink drain be offset?

Quote from the video:
Quote from Youtube video: It's all about space economy opposite drains are typically not the first thing that come to mind when purchasing a sink there are many benefits to having the drain offset from the center.

How much fall does a sink drain need?



¼ inch per foot

Improper drain slope



You probably know that drains need to flow downhill into your sewer. But do you know the proper slope? The ideal slope of any drain line is ¼ inch per foot of pipe. In other words, for every foot the pipe travels horizontally, it should be dropping ¼ inch vertically.

How far should the sink drain be from the wall?

Discharge hole (vertical): Drain located at floor height; distance is zero. Fixture (side to side buffer): Measured from center of the toilet to either side, minimum. clearance is 15 inches to any wall or other fixture; 18 inches is recommended if the bathroom layout allows for this.

How far can a drain go without a vent?

If you have 1 ¼-inch pipe, the horizontal distance of the vent should not be more than 30 inches. For a 1 ½-inc pipe the vent should be 42 inches away at the most while a 2-inch pipe must have a maximum distance of 5 feet.

Does every P-trap need a vent?



P-traps need vents



1 – They give the sewer gases a place to vent, so they do not build pressure inside your sewer lines.

How close does a vent need to be to a sink?

Install the vent between the sink P-trap and the point where the waste line leading from the trap drops to the main sewer. If the waste line has a diameter of 1 1/4 inches, the vent can be no farther than 2 1/2 feet from the trap. If the waste line is 1 1/2 inches, this critical distance is 3 1/2 feet.

Can a toilet and sink share a vent?

A general rule is that you can only vent 2 fixtures on a toilet wet vent. The sink drain has a toilet vent through it. The toilet drain should be 3′′, the sink drain is 1.5′′, the shared sink drain/toilet vent area should be 2′′, and the vent going up should be 1.5′′.

Can you tie a sink drain into a toilet drain?

Connect the sink drainpipe to the toilet drainpipe using a 2-inch-to-3-inch sweeping-Y connector. The sink drain should enter the toilet drain from above, and the 2-inch opening for the sink drain should extend upward from the 3-inch horizontal drainpipe to prevent backflow issues.

Can you connect kitchen sink waste to toilet waste?



Yes, but the sink must empty into the toilet drain. Toilets have the largest drainpipe, so plumbers empty the bathroom sink drain, which is smaller in diameter, into the toilet drain line. They install a common vent that allows water and waste to drain without forming an airlock.