How do I run a wire through my garage ceiling?

Quote from the video:
Quote from Youtube video: They make drill bits. That are this long and flexible. So what you do is you get to where you need to go and if you have to go over to the next can you'll slide this in bend.

Does garage wiring have to be in conduit?





Many garages contain one or more walls made of concrete or already drywalled. Cable installed on these exposed surfaces has to be protected by conduit. We show EMT (electrical metallic tubing; Photo 7), but you can also use rigid PVC conduit.

How do I get cables through my ceiling?

Quote from the video:
Quote from Youtube video: Not enough angle and sometimes you can get too much and force it coming backwards. And come out the inside.

Can electrical wire be exposed in garage?

Most homeowners use Romex for electrical wirings on their property. As electrical wirings are found everywhere homeowners often wonder – can Romex be exposed in the garage? The short answer to the question is – no, you should never expose your Romex wiring in your garage.

Can you run electrical wire through ceiling joists?

Running electrical wire through the channel between ceiling joists is generally easiest. In addition, your light fixture may require mounting to a ceiling joist or to two short blocks nailed between the joists. Trace and mark the fixture hole and cut out with a drywall saw, utility knife or reciprocating saw.

Is it legal to run Romex in conduit?





No, you can not run your Romex wiring in conduits.

Does Romex need conduit in garage?

Code and common sense both dictate that Romex shouldn’t be left exposed but must run through conduits. If you are running it through the basement or attic (or both), the wire must past through studs or be secured on top of joists or trusses.

What is code for outlets in garage?

However, the code is just a minimum set of installation rules. The basic rule for garage receptacles is that one receptacle outlet needs to be installed in each vehicle bay and not more than 5 ½ feet above the floor.

Can you run PVC conduit in garage?

Combining metal boxes and PVC conduit is fine, but unlike an all-metal system, PVC requires you to run a separate ground wire and bond it to each metal box or light fixture with either a screw or a special grounding clip. There are a few different techniques for measuring PVC.

Is MC better than Romex?



Safety: Compared to Romex, MC cable is safer to install due to its metallic sheath. This sheath helps protect against accidental shearing and penetration, reducing the risk for accidental wire exposure. Romex sheathing is easily penetrated or sheared, making it less safe unless run through protective conduit.

Can you run MC wire outside?

Type MC Cable without an outside nonmetallic jacket can be installed in an “other space used for environmental air” in accordance with Section 300.22(C). These cables can be installed either indoors or outdoors and in exposed and concealed locations. They can be direct buried, where identified for such use.

Why is Romex so high?

These price increases are due to factors such as China’s economic recovery from the pandemic, sustainable green energy stimuluses, and supply disruptions. China’s rising industrial production along with aggressive sustainable energy initiatives accredits the country to being the highest consumer of copper in the world.

Is BX cable the same as MC cable?



BX became the registered trade name of AC Cable distributed by General Electric who had acquired Sprague Electric. The biggest difference between the two cable systems is that MC has full size ground wire while AC uses a combination of the jacket and a thin bonding strip or wire to function as the equipment ground.

Is BX cable legal?

BX is accepted by the National Electrical Code (NEC). Older BX cables without an internal bonding strip are not accepted by NEC.

Does MC cable need to be bonded?

According to NEC Article 330.30, MC cable must be supported and secured at intervals of 6 feet or less (unless routed through a framing member) and cables containing four or fewer conductors sized no larger than 10 AWG must be secured within 12 inches of every termination.

Does MC cable have a ground?

MC-Stat® MCI-A cable has a full-sized insulated copper conductor as a second equipment grounding means for healthcare applications.

Can you surface mount MC cable?



New for the 2017 NEC Code-cycle is section 330.15, entitled “Metal-Clad Cable: Type MC Exposed Work.” This new Code section requires an exposed run of MC Cable to closely follow the surface to which it is mounted while enjoying a new permission that allows the MC cable to be installed on the underside of floor joists.

How often does Romex need to be stapled?

Runs of NM cable must be supported at least every 54 inches. 1 They also must be secured within 12 inches of an electrical box that includes a cable clamp or within eight inches of a box or enclosure without a cable clamp.