Each wire that enters the box and is terminated on a device counts as one. Each wire that passes through the box without making a joint counts as only one. All gound wires only count as one no matter how many ground wires you have. Wires that originate in the box and stay in the box, such as pigtails, do not count.

How do you calculate wire fill in a box?


Quote from Youtube video: The ground you can have one ground you can have to ground you can have three ground you can have ten grounds. The ground in a box fill calculation is counted as one.

Do fixture wires count in box fill?

Under certain conditions, up to four luminaire (fixture) conductors and one equipment-grounding conductor can be installed but not counted in the box-fill calculation. The conductors must be 16 AWG or smaller and must enter the box from a domed luminaire (fixture) or similar canopy.

How many wires can go in a 22.5 cu in box?

10 wires×2.25 cu in. =22.5 cu in.

How do you count electrical wires?

Each item in an electrical box counts as a different number of wires. Each insulated wire, all cable clamps combined, all uninsulated wires combined, and each support for light or another fixture count as one wire. Each switch, outlet, or other device counts as two wires.

How many electrical wires are in a box?

Plastic Box Fill Capacities



Single Gang Boxes: A total capacity of 18 cubic inches allows for nine #14 gauge wires, eight #12 gauge wires, or seven #10 gauge wires. This is a wires-only capacity. With one device added to the box, subtract two wires in each category.

How many wires are allowed in a junction box?

For example, the smallest 2-by-4-by-1-1/2-inch-deep box can comfortably splice only two cables (four or five conducting wires), while the largest 4-by-4-by-2-1/8-inch-deep boxes can handle as many as four to six cables (up to 18 individual conducting wires).

Which of the following will count as a conductor in a box fill calculation?

A wire that has its origin inside a device box and does not leave the device box, such as a pigtail, counts as one conductor when computing box fill.