How do you calculate the distance of a wire?

Quote from the video:
Quote from Youtube video: From the long wire to the left hand side of the loop and in this case that's given the symbol C on the diagram. And then the distance from the wire one to the right hand side of the loop.

How far can you run electrical wire?





The following are the maximum lengths of cable you can use while still maintaining a 3 percent voltage drop for the given wire size (AWG) and circuit voltage.



For 120-volt circuits:

14 AWG 50 feet
12 AWG 60 feet
10 AWG 64 feet
8 AWG 76 feet
6 AWG 94 feet


How do you run electricity over long distances?

At a power plant, a transformer increases the voltage of generated power by thousands of volts so it can be sent of long distances through high-voltage transmission power lines. Transmission lines are bundles of wires, known as conductors, that ship electric power from power plants to distant substations.

How far into the wall is wiring?

about an inch





How far into the wall are wires located? Wiring usually runs horizontally, about an inch into the wall. The parameters are 6 inches or 12 inches above the receptacle.

How do you find the distance between two parallel wires?

The distance between the wires results from finding the hypotenuse of a triangle: r=√(3.0cm)2+(4.0cm)2=5.0cm. The force per unit length can then be calculated using the known currents in the wires: Fl=(4π×10−7T⋅m/A)(5×10−3A)2(2π)(5×10−2m)=1×10−10N/m.

How do you calculate amps from distance?

How to Calculate Amperage Drop Over a Distance

  1. Multiply the current you will be sending through your line by the total round-trip distance that you will be sending it. …
  2. Take the number that you got by multiplying these two factors and double it.

How far can you run 12 gauge wire on a 20 amp circuit?

After these distances, the circuit will go over the recommended 3% voltage drop. You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

How far can you run a 30 amp wire?



Other Things You Need to Consider When Installing a 30 Amp Circuit Breaker. You must also consider the wire length for your 30-amp circuit, in addition to the wire AWG. A maximum length of 150 feet is allowed when using a 10-gauge wire size.

How many outlets can be on a 15 amp circuit?

8 outlets

Technically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a maximum of 8 outlets for a 15 amp circuit.

What is the height for electrical outlets?



Standard Height for Outlet Boxes



The standard height for wall outlet boxes is about 12 inches from the top of the floor covering to the bottom of the receptacle box (or 16 inches to the top of the box).

Where do I drill electrical wiring?

When running cable through studs, drill all holes at the same height so that the cable is run level to the floor. Drill holes 6 to 8 in. above or below all switch and receptacle boxes.

How do you trace wires in a wall?

Quote from the video:
Quote from Youtube video: Turn on the receiver and push the function button until precision mode is selected scan the wall and adjust the sensitivity. Until you find a signal strength of 50 to 75%.

What is the force between two parallel wires?

This force between two current carrying wires gives rise to the fundamental definition of the Ampère: If two long parallel wires 1m apart each carry a current of 1A, then the force per unit length on each wire is 2×10−7N/m.

How do you calculate the force between two wires?



A similar analysis shows that the force is repulsive between currents in opposite directions. This field is uniform along wire 2 and perpendicular to it, and so the force F2 it exerts on wire 2 is given by F=IlBsinθ with sinθ=1: F2=I2lB1.

What is force per meter?

Quote from the video:
Quote from Youtube video: Number 34 letter a what is the force per meter on a lightning bolt at the equator that carries 2 000 amps perpendicular to the earth's 3 times 10 to the minus 5th tesla. Field all right so anytime you

What is the force per unit length between the wires?

Force per unit length acting on the wire B due to A F=2πrμoI1I2.

How do you find the force per unit length of a wire?

The force per unit length can then be calculated using the known currents in the wires: Fl=(4π×10−7T⋅m/A)(5×10−3A)2(2π)(5×10−2m)=1×10−10N/m.

What has a unit of N M?



torque

The newton-metre (also newton metre or newton meter; symbol N⋅m or N m) is a unit of torque (also called moment) in the SI system. One newton-metre is equal to the torque resulting from a force of one newton applied perpendicularly to the end of a moment arm that is one metre long.

How do you calculate nm?

Motor Torque T(Nm) in Newton meter (Nm) is equal to 9.554140127times of the electric power P(W) in watts divided by the speed N(rpm) in rpm. Example: Calculate the rated torque can be developed by the 22000 Watts, 1490 rpm three-phase motor. T(Nm) = 144 Nm.

What is 1N m2?

1 Pascal

1 N/m2 = 1 Pascal. Pascal (Pa) is an SI-derived pressure unit used to measure internal strain, stress, Young’s modulus and overall tensile power. The unit, named after Blaise Pascal, is defined as one tone per square meter. The unit of measurement called atmospheric (atm) is specified as 101325 Pa.