What kind of pipe do you use for a bathroom fan?

PVC Schedule 40 Foam core pipe is the ideal pipe for bathroom fan venting. This type of piping is non-toxic, easy to install, and is code compliant. The PVC pipe fittings can be safely cemented and sealed, preventing any water that might collect in the pipe from leaking and causing water damage.

How do you route a bathroom exhaust duct?





Quote from the video:
Quote from Youtube video: Out first thing i want to do is remove some of the roof shingles so i can drill a hole all right now i'm going to measure the vent hood. It's five and a half inches.

Can you use PVC to vent a bathroom fan?

I’d seriously consider using foam core PVC pipe as the vent pipe for your fan. The fittings can be glued, and any water that might form in the pipe will never leak onto your ceiling or down a wall.

Should you install a bathroom vent directly over the shower?

You can place the fan directly over the bathtub or shower base, but it’s sufficient to position it anywhere near the bathing area. If the bathroom has both a tub and shower, or a shower and a whirlpool tub, the fan should go somewhere between the two fixtures.

Can you use flex pipe for bathroom vent?

Can You Use Insulated Flexible Duct for Bathroom Fan? You can either buy flexible ducting and then insulate it yourself, or you can buy flexible ducting that has already been insulated. You definitely can use the latter for your bathroom fan.

Can I use flexible duct for bathroom vent?





The flexible insulated duct is recommended for this application to minimize condensation in bathrooms (or other warm and moist areas), and can also be helpful in reducing fan noise.

What is code for venting a bathroom fan?

Section 1203.4. 2.1 of California’s building code requires all bathrooms with a bathtub, shower, spa or similar fixtures to be ventilated by an exhaust fan. The fan must be Energy Star-compliant and vented to the outside.

Does bathroom exhaust duct need to be insulated?

The bathroom exhaust duct should be insulated when it passes through an unconditioned space. This means that the temperature of the space is not controlled. Most exhaust ducts run through an unheated/cooled attic and must be insulated to prevent condensation inside and outside of the duct.

How long can the duct be for a bathroom fan?

Typically in all bath fans I seen go in, a 30′ run was allowed IF there was no elbows used. If elbows are used, which will be pretty much the case in any install, you need to deduct 5′ for each elbow added.

Is it OK to vent a bathroom fan through the soffit?



A bathroom fan can be vented through soffit so that the warm air from the bathroom comes out through it and goes outside. However, It is important to keep in mind it can not be vented into the soffit, as this will lead moisture back into the attic.

Where is the best place to vent a bathroom fan?

The fan exhaust must vent directly to the exterior of the home. Do not put the vent termination in a roof overhang or soffit. Don’t put it on a wall near or under a roof overhang. The moist air that’s belched out by the fan can be sucked right up into the open soffit vents and be drawn into your attic.

Should bathroom fan vent into attic?

No, you should not vent a bathroom fan directly into an attic. The problem with venting into the attic is that the moisture-rich air may form droplets on the wood sheathing, insulation, rafters, and ceiling joists, leading to mold growth.

How do you attach a flex duct to an exhaust fan?



Quote from the video:
Quote from Youtube video: Right over the top of it and you're gonna hear it crimp down and clip it nice and tight.

Can I use 3 duct for bathroom fan?

Taking a bathroom fan that is 80 to 120 cfm from a 4 inch outlet to a 3 inch duct is not an issue. It will work just fine and suck the bad air out very well. This will not be any difficulties and you will not notice any problems (as there will be no problems).

How long should a bathroom vent hose be?

Fantech recommends a minimum of eight feet of insulated flex duct between the exhaust inlet register or grille and the fan motor. The company does not cite a maximum exhaust duct length.

Can you have too much CFM in bathroom?

But there are many reasons why this is not true. A Bathroom fan should not be overpowered since this will waste energy, create excessive noise and could even pull noxious carbon monoxide into the home. It is OK to get a 20-30 % higher capacity exhaust fan than specified by the CFM calculator.

Can you use 2 inch pipe for bathroom fan?



A 2″ pipe would carry less than 25% of the airflow that a 4″ pipe would carry, and probably wouldn’t be sufficient for any size shower (unless you used some sort of high-pressure fan, which isn’t what a bathroom vent fan would be).

What size pipe is used for bathroom vent?

When you operate the fan, typically air is pulled from the bathroom through a 4 inch exhaust pipe. The space under the door should be, at a minimum, the size of the opening in the pipe.

Can you use dryer duct for bathroom fan?

A bathroom fan and a dryer should never share the same vent. International building code states that dryer vent exhaust systems must be separate from all other systems and must expel moisture out of the house through a dedicated vent. This is because of the potential hazards associated with improper dryer venting.