How far can you run a bathroom exhaust fan vent?

Generally a 4 inch flex duct can carry a fan exhaust for up to 25 ft. Most codes require that.

How long can you run a bathroom exhaust fan?





Experts agree that you should not leave your bathroom fan on all night. You should only run the fan for about 20 minutes during and after a bath or shower. You especially shouldn’t leave it on at night. If it’s run too long, it can cause serious problems and become a fire hazard.

Can you run 2 exhaust fans 1 duct?

Well, you can’t! You’d often blow air from one bathroom into the other, and local building inspectors wouldn’t approve it. But while you can’t have two fans with one vent, you can make one fan and one vent serve two bathrooms.

Can I use 3 duct for bathroom fan?

Taking a bathroom fan that is 80 to 120 cfm from a 4 inch outlet to a 3 inch duct is not an issue. It will work just fine and suck the bad air out very well. This will not be any difficulties and you will not notice any problems (as there will be no problems).

How big should my bathroom exhaust fan be?

The rule of thumb is that you need at least 1 CFM per square foot of room area. To determine the square footage of your bathroom, multiply the length times the width. For example, if your bathroom is six feet wide and nine feet long, its square footage is 54. Therefore, it should have a fan rated for at least 54 ​CFM.

What is code for venting a bathroom fan?





Section 1203.4. 2.1 of California’s building code requires all bathrooms with a bathtub, shower, spa or similar fixtures to be ventilated by an exhaust fan. The fan must be Energy Star-compliant and vented to the outside.

What size duct do I need for 1600 cfm?

12-Inch Rectangular Ducts Size Chart (150-3,050 CFM)

12″ Duct 12″ CFM
20×12 1,250 CFM
22×12 1,400 CFM
24×12 1,600 CFM
26×12 1,750 CFM

How long can a duct run be?

If you choose well, you can be at 10 or 20 feet of effective length. If you choose that smooth mitered elbow, however, you end up with 75 feet.

How do I calculate duct size for exhaust fan?

The minimum duct size for a range hood is 4”, which is ideal for range hoods 400 CFM and under. The higher the cubic feet per minute, the larger the duct you’ll need. At 600 CFM, the minimum duct size is 6”. At 900 CFM, the minimum duct size is 8”.

What size duct do I need for 2000 CFM?



Rectangular equivalent diameter for air flows between 100 – 50000 cfm.

Air flow – q – (Cubic Feet per Minute, cfm) (m3/s) Rectangular Duct Sizes (inches) (mm) x (mm)
1700 (0.77) 10 x 22 14 x 15
1900 (0.86) 12 x 19 14 x 16
2000 (0.9) 10 x 25 12 x 20 15 x 16
2500 (1.13) 14 x 20 15 x 18

What are standard duct sizes?

The size of ductwork affects the amount of airflow and its velocity and is very important in how well the HVAC system operates. Rectangular ducting can come in various sizes from 3” x 7” up to 35” x 40”; and round ducting can be anywhere from 4” to 41” in diameter.

How do you measure HVAC duct size?

Measure the end of a square or rectangular duct each way to determine the size. If the duct fitting inside the wall transitions to a circular duct, measure inside the circular duct from top to bottom. Repeat this at the remaining grills and ducts throughout the house.

Can ductwork be too big?



Too big – Oversized ducts will give the heated or cooled air they carry more time to come to room temperature before they get through the vents and into the room, so you’ll end up with less heating or cooling where you want it, and the system being overworked to meet demand.

How is the equivalent length of a duct determined?

How is the equivalent length of a duct determined? Add the trunk duct length to takeoff, the branch duct length, and the equivalent lengths of all fittings used from blower to register.

How do you tell what size duct you have?

If you have round ducts, you simply measure the diameter (D) of the duct (the cross-section). This will tell you what size duct to purchase to replace it. If you have rectangular or square ducts, measure the width (W) and height (H) of the duct and use these figures when buying new parts.

What are the three methods for determination of duct size explain them?

Design Master HVAC can size ducts using three different methods: constant pressure drop, constant velocity, and static regain. All of these sizing methods are fairly straightforward. The also all include a minor adjustment you can make to the sizing.

Is duct code a measure?



IS 655: Specification for Air Ducts.