Vents should be 6” above flood-level rim of fixture before offsetting horizontally, or need to use drainage fittings and grade to drain. Vents shall rise to 6” above flood-level rim of fixture served before being connected to any other vent.

What is the minimum horizontal height for venting?

6 inches





Horizontal vent pipes forming branch vents, relief vents or loop vents shall be located not less than 6 inches (152 mm) above the flood level rim of the highest fixture served.

When can a vent go horizontal?

Can Vent Pipeline be Horizontal? There is no problem with running your vent pipes horizontally as long as you remember that there should be a minimum clearance of 6 inches above the spill line.

What is the minimum height of a vent pipe?

6 in.

The International Plumbing Code (IPC), requires plumbing vent pipes to extend vertically at least 152 mm (6 in.) above a roof, per Section 905.5, “Vent Connections and Grades.” Additionally, vent pipes must be at least 305 mm (12 in.) away from a vertical surface.

Can a vent stack have a horizontal run?





To answer your specific question, yes, vent pipes can have horizontal runs, as long as there is no possibility of them becoming plugged with water. In other words, any water that gets into the vent pipe opening must be able to run freely all the way to the sewer, without creating a “trap”.

Do Horizontal vent pipes need to be sloped?

Vent pipes, often narrower than drainpipes, need not slope like drainpipes. Normally they run level or plumb unless there is an obstacle to work around.

Can plumbing vents be combined?

Vent pipes shall be extended separately or combined, of full required size, not less than 6 inches (152 mm) above the roof or fire wall.

Can a toilet shower and sink share a vent?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.

Can plumbing vent go out side wall?



You can pass the vent through a wall instead of through the roof, but it must still rise over the roof.

Does a plumbing vent have to go through the roof?

The answer is, no, plumbing vents do not have to go through the roof. While roof stacks are the most common form of plumbing vents, you can run a plumbing vent through an exterior wall. The stipulation is that the plumbing vent has to run higher than the highest window of the house.

How far can a toilet vent be?

6 feet



According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.

How far should a plumbing vent stick out of the roof?

6 inches

Vent pipes shall terminate not less than 6 inches above the roof, measured from the highest point where the vent intersects the roof. EXCEPTION: Where a roof is used for any purpose other than weather protection, vents shall extend at least 7 feet above the roof and shall be properly supported.

Can a plumbing vent go into attic?

Yes, a plumbing vent can terminate in the attic. But it must have an air admittance valve at the termination to keep noxious sewer gas fumes from rising into the attic.

How high should a vent be above a roof?



Unless a roof is to be used for any purpose other than weather protection, extensions of vent pipes through a roof should be terminated at least 12 inches above the roof. The vent should be extended at least seven feet above the roof if it is to be used for something other than weather protection.

What happens if you don’t vent a drain?

Poorly-vented drain lines will not be able to effectively move wastewater and solid waste out of your building. This could lead to problems such as overflowing drains, backed-up toilets, and similar plumbing issues.

Can a toilet be vented through a wall?

Alternative to a Roof Stack

All the vents connect to it through branch lines, and it vents the main toilet, the most important plumbing fixture in most houses. If you can’t put the main stack through the roof, most local plumbing codes allow you to put it through a wall instead, but there are conditions.

Can a toilet flush without a vent?



Yes, every toilet needs a vent pipe to work well. Without it, your toilet could not get rid of waste and debris. The toilet needs venting to balance the atmospheric pressure, enable the flush system, and prevent awkward smells.

Is there a ventless toilet?

Ventless toilets are just like regular ones, except there is no vent for the toilet to release the water vapor. Instead, they use a siphon action that pulls the water out of the toilet bowl into an underground waste pipe.